During the observation period set out in accordance with Article 4, Member States shall collect data on night-active moths at each monitoring site by using light traps.
The light traps shall be active for one night a month during the observation period, with a minimum time interval between active periods of a light trap at the same monitoring site of three weeks.
By way of derogation from paragraph 2, where the environmental conditions referred to in paragraph 6 are not met over an extended period of time which prevents the monthly placing of light traps, the light traps may be placed less frequently than once a month.
By way of derogation from paragraph 2, the light traps may be placed more frequently than once a month at monitoring sites where the observation period is shorter than six months. In this case, the minimum time interval shall be less than three weeks.
During the active period of each light trap, the following environmental parameters shall be recorded:
temperature (in °C);
cloud cover (in oktas);
wind speed (in m/s);
fog (presence/absence);
precipitation (presence/absence);
principal moon phase (new moon, first quarter, full moon, last quarter);
any other relevant parameters that may affect the data collection.
Light traps shall be placed under environmental conditions during which the species referred to in paragraph 1 are active at the adult stage of their lifecycle. For this purpose, for the environmental parameters listed in paragraph 5, points (a) to (f), Member States shall specify the conditions under which the light traps are to be placed. Those conditions may be adapted to the circumstances at each site and shall not be changed in the course of an assessment period.
Two light traps shall be placed at each monitoring site, with a distance of at least 50 m between them. The light traps shall be placed at least 10 m from water bodies, and at least 50 m from artificial light sources. They shall be placed in such a manner that the top of the light source is between 30 cm and 1 m above ground level. A 1 m radius around each trap shall be free of obstructions that could block the light of the trap.
The position of the light traps shall be georeferenced and mapped for each monitoring site before data collection starts. Each light trap shall be attributed to one of the ecosystem types referred to in Article 3(4), first subparagraph. The location of each light trap shall not be changed in the course of an assessment period, unless it becomes inaccessible due to force majeure.
Member States shall use an identical light trap design and an identical light source type at all monitoring sites. The light trap design and the light source type shall not be changed in the course of an assessment period.
By way of derogation from the first subparagraph, a different light trap design and light source type may be used in latitudes higher than 60° N.
The light source of each light trap shall have a high output in the ultra-violet and blue light range (350-550 nm). The light sources shall be duly maintained with no substantial changes in light intensity or spectral composition over time.