ANNEX V VERIFICATION PROCEDURE FOR MARKET SURVEILLANCE PURPOSES REFERRED TO IN ARTICLE 5, Regulation (EU) 2025/2052

In forcesince 13 Oct 2025
1.

The verification tolerances defined in this Annex relate only to the verification by Member State authorities of the declared values and shall not be used by the manufacturer, importer or authorised representative as an allowed tolerance to establish the values in the technical documentation or in interpreting those values with a view to achieving compliance or to communicate better performance by any means.

2.

Where a model does not comply with the requirements laid down in Article 40 of Regulation (EU) 2024/1781, the model and all equivalent models shall be considered non-compliant.

3.

As part of verifying the compliance of a product model with the requirements laid down in this Regulation, the authorities of the Member States shall apply the following procedure:

(a)

the Member State authorities shall verify one single unit of the model;

(b)

the model shall be considered to comply with the requirements set out in this Regulation if all the following conditions are fulfilled:

(1)

the declared values given in the technical documentation pursuant to point 2 of Annex IV to Directive 2009/125/EC and, where applicable, the values used to calculate those values are not more favourable for the manufacturer, importer or authorised representative than the results of the corresponding measurements carried out pursuant to point 2(g) of that Annex;

(2)

the declared values meet any requirements laid down in this Regulation and any required product information published by the manufacturer, importer or authorised representative does not contain values that are more favourable for the manufacturer, importer or authorised representative than the declared values;

(3)

when the Member State authorities check the unit of the model, it complies with:

(i)

the interoperability requirements in point 3 of Annex II to this Regulation, and

(ii)

the information requirements in point 5 of Annex II to this Regulation, as applicable;

(4)

when the Member State authorities test the unit of the model, the determined values (the values of the relevant parameters as measured in testing and the values calculated from those measurements) comply with the respective verification tolerances set out in Table 9.

4.

Where the conditions set out in points 3(b)(1), (2) or (3) are not met, the model and all equivalent models shall be considered not to comply with this Regulation.

5.

If the condition set out in point 3(b)(4) is not met, with the exception of the surge resistibility requirement, the Member State authorities shall select three additional units of the same model for testing. As an alternative, the three additional units selected may be of one or more equivalent models.

6.

The model shall be considered to comply with the applicable requirements if, for the three units referred to in point 5, the arithmetical mean of the determined values complies with the respective verification tolerances given in Table 9.

7.

If the condition set out in point 3(b)(4) is not met as regards the surge resisibilility requirements, the Member State authorities shall select three additional units of the same model or of an equivalent model for testing. The model and all equivalent models shall be considered not to comply with this Regulation as soon as the test is failed by one of the three additional units. In this case, the other units not yet tested do not need to be tested. The model shall be considered to comply if the test is passed by each of the three additional units.

8.

Where the condition set out in points 6 or 7 is not met, the model and all equivalent models shall be considered to be not in compliance with this Regulation.

9.

The Member State authorities shall without delay provide all relevant information to the authorities of the other Member States and to the Commission through the information and communication system referred to in Article 34 of Regulation (EU) 2019/1020 after a decision has been taken on the model’s non-compliance pursuant to points 2, 4, or 8 of this Annex.

10.

The Member State authorities shall use the measurement and calculation methods set out in Annex IV.

11.

The Member State authorities shall only apply the verification tolerances that are set out in Table 9. They shall use only the procedure described in this Annex for the requirements referred to in this Annex. For the parameters in Table 9, no other tolerances, such as those set out in harmonised standards or in any other measurement method, shall be applied.

12.

The parameters ‘Input voltage’ and ‘Input AC frequency’ of EPS as required in Table 7 of Annex II to this Regulation shall not be subject to compliance verification under this Regulation. The parameters ‘Active output power (W)’ and ‘Root mean square input power (W)’ of EPS as required in Table 8 of the same Annex, and ‘Input voltage (V) or input voltage range (if applicable)’ of wireless charging pads as required in point 6(h)(3) of the same Annex are meant not to be verified.

[For AC output voltage, these shall be root mean square values.] [In the case of the three additional units tested as prescribed in point 5, the determined value means the arithmetical mean of the values determined for those three additional units.]

Parameter | Verification tolerance

For EPS

Output voltage (V) | The determined value shall not be lower than the declared value by more than 2 %.

Active mode efficiency at each of the applicable load conditions | The determined value shall not be lower than 0,95 times the declared value.

Power consumed (W) at no-load condition | The determined value shall not exceed the declared value by more than 0,01 W.

For wireless chargers and wireless charging pads

Power consumed (W) in standby mode | The determined value shall not exceed the declared value by more than 0,01 W.