The 66 European Assessment Documents relate to the following references for construction products:
balcony and terrace glazing systems without vertical frames (superseding technical specification ‘EAD 020002-00-0404’);
external thermal insulation composite systems with rendering system (superseding technical specification ‘EAD 040083-00-0404’);
factory-made products of extruded, foamed polyethylene terephthalate for thermal insulation;
veture kits – prefabricated units for external wall insulation and their fixing devices (superseding technical specification ‘EAD 040914-00-0404’);
kits made of insulation boards with protective finishing for inverted roofs;
pre-wall mounting kits for windows and doors;
thermal insulation elements of fibre-reinforced polymer which form a thermal break between structural elements;
load-bearing thermal insulation elements which form a thermal break between balconies and internal floors (superseding technical specification ‘EAD 050001-00-0301’);
spherical and cylindrical bearings with special sliding material made of ultra-high-molecular-weight polyethylene (superseding technical specification ‘EAD 050004-00-0301’);
spherical and cylindrical bearings with special sliding material made of fluoropolymer (superseding technical specification ‘EAD 050009-00-0301’);
pre-assembled drainage panels made of gabions and geotextile;
kits composed by subframe and fixings for fastening claddings and external wall elements (superseding technical specification ‘EAD 090034-00-0404’);
variant: kits for external wall claddings mechanically fixed – extension of scope;
glass-ceramic panels for external cladding;
full-bodied sintered stone slabs for use in claddings, floorings, pavings, stairs, rainscreens and curtain walling kits;
kits for self-supporting and interconnected ventilated cavity walls;
wood-based composite panel for facades;
rigid seismic sway brace for fire sprinkler pipe work;
flexible plug expansion joints for road bridges with flexible filling based on a synthetic polymer as binder (superseding technical specification ‘EAD 120011-00-0107’);
wood and metal lighting columns;
glued laminated veneer lumber;
glulam strengthened by laminated veneer lumber, glued laminated veneer lumber made of finger-jointed laminations and block-glued glulam made thereof;
special cements – carbonation hardening cements requiring a particular curing process;
blended cements with high filler content, ground granulated blast-furnace slag or pozzolanic material or both, and clinker;
kits for the strengthening of concrete elements by externally bonded and near-surface-mounted carbon fibre-reinforced polymer strips (superseding technical specification ‘EAD 160086-00-0301’);
couplers for mechanical splices of reinforcing steel bars (superseding technical specification ‘EAD 160129-00-0301’);
stud connectors for anchoring in reinforced concrete members as well as for connecting steel members with reinforced concrete members;
compressed solid earth blocks with or without lime or cement and wall kits made of these blocks and natural hydraulic lime mortar;
column shoes for structural connections of reinforced concrete columns;
structural hollow sections of weathering steel;
fiber ropes with end connectors;
thin metal composite sheets (superseding technical specification ‘EAD 210046-00-1201’);
variant: assessment of components for wood-based composite panels not produced by the manufacturers themselves;
non-load-bearing polyvinyl chloride panels for internal and external walls;
low-bitumen-mass shingles, laminated or not, with mineral or synthetic reinforcement (superseding technical specification ‘EAD 220020-00-0402’);
fastening screws with welded or cold-formed set screws;
fixing clips and sliding clips for double standing seam roof;
variant: road marking products – extension of scope;
variant: compound for bitumen and bituminous mixtures based on crumb rubber powder – extension of scope;
stone wool elements used for large-scale water storage in civil works;
adhesives for wall claddings;
products for installation systems for supporting technical building equipment;
variant: anchor channels under fatigue cyclic shear with different lower load level;
variant: anchor channels for controlled impact screwdrivers;
mechanical fasteners for use in concrete (superseding technical specification ‘EAD 330232-01-0601’);
post–installed fasteners in concrete under fatigue cyclic loading (superseding technical specification ‘EAD 330250-00-0601’);
variant: plastic anchors for redundant non-structural systems in concrete and masonry, and for fixing façade claddings through angle brackets under seismic actions in concrete and masonry;
screw anchors for use in masonry;
variant: cast-in anchor bolts under fatigue or seismic actions;
high-strength structural bolting assemblies for hydraulically operated, friction-less and torsion-free tightening;
anchor devices for fastening personal fall protection systems to timber substructures (superseding technical specification ‘EAD 331846-00-0603’);
distance-fixing systems for use in concrete and masonry;
kits for connection of precast concrete façade elements to concrete structures based on anchor channels;
support fixing assemblies;
point fastening kits for roof panels;
anchor devices for fastening personal fall protection systems to steel or aluminium trapezoidal sheeting substructures;
permanent insulating shuttering kits for whole buildings;
load-bearing sandwich panels with foam or polymeric core and skins of structural cement bonded particle boards;
earthquake-resistant kits composed of steel-concrete composite beams, columns and beam-column joints;
variant: non-load-bearing permanent shuttering kits or systems based on hollow blocks or panels of insulating materials and sometimes concrete: hollow blocks resistant to seismic actions;
fibre-reinforced polymer kits made of a pultruded carbon fibre laminate and an epoxy adhesive;
fibre-reinforced polymer kits made of a carbon or glass fabric and an epoxy resin;
structural steel composite wall panels for building systems;
high load-bearing and low load-bearing single anchor earth retaining structures made of steel;
fire-resistant reactive air transfer grilles;
caps with intumescent inlay for recessed luminaires in fire-resistant suspended ceilings.