Table 1 defines the scope of different categories of short-range devices (defined in Article 2(3)) to which this Decision applies. Table 2 specifies different combinations of frequency band and category of short-range devices, and the harmonised technical conditions for spectrum access and implementation deadlines applicable thereto.
General technical conditions applicable to all bands and short-range devices that fall within the scope of this Decision:
Member States shall allow adjacent frequency bands set out in Table 2 to be used as a single frequency band provided the specific conditions of each of these adjacent frequency bands are met.
Member States shall allow the usage of spectrum up to the transmit power, field strength or power density set out in Table 2. Pursuant to Article 3(3), they may impose less restrictive conditions, that is to say allow the use of spectrum with higher transmit power, field strength or power density, provided it does not reduce or compromise the appropriate coexistence between short-range devices in bands harmonised by this Decision.
Member States may only impose the additional parameters (channelling and/or channel access and occupation rules) set out in Table 2, and shall not add other parameters or spectrum access and mitigation requirements. Less restrictive conditions pursuant to Article 3(3), means that Member States may completely omit these additional parameters in a given cell or allow higher values, provided that the appropriate sharing environment in the harmonised band is not compromised.
Member States may only impose the other usage restrictions set out in Table 2 and shall not add additional usage restrictions. Since less restrictive conditions may be applied pursuant to Article 3(3), Member States may omit one or all of these restrictions, provided that the appropriate sharing environment in the harmonised band is not compromised.
Less restrictive conditions pursuant to Article 3(3) shall apply without prejudice to Directive 2014/53/EU.
For the purposes of this Annex, the following duty cycle definition applies:
“duty cycle” means the ratio, expressed as a percentage, of Σ(Ton)/(Tobs) where Ton is the “on” time of a single transmitter device and Tobs is the observation period. Ton is measured in an observation frequency band (Fobs). Unless otherwise specified in this technical annex, Tobs is a continuous one hour period and Fobs is the applicable frequency band in this technical annex. Less restrictive conditions within the meaning of Article 3(3), mean that Member States may allow a higher value for “duty cycle”.
[Council Directive 90/385/EEC of 20 June 1990 on the approximation of the laws of the Member States relating to active implantable medical devices (OJ L 189, 20.7.1990, p. 17).]
Category of short-range devices | Scope
Non-specific short-range devices (SRD) | Covers all kinds of radio devices, regardless of the application or their purpose, which fulfil the technical conditions as specified for a given frequency band. Typical uses include telemetry, telecommand, alarms, data transmissions in general and other applications.
Active medical implant devices | Covers the radio part of active implantable medical devices that are intended to be fully or partially introduced, surgically or medically, into the human body or that of an animal, and where applicable their peripherals. Active implantable medical devices are defined in Council Directive 90/385/EEC.
Assistive listening devices (ALD) | Covers radio communications systems that allow persons with hearing impairment to increase their listening capability. Typical system installations include one or more radio transmitters and one or more radio receivers.
Audio Programme Making and Special Events (PMSE) devices | Covers radio devices used for transmission of analogue or digital audio signals between a limited number of transmitters and receivers, such as radio microphones, in-ear monitors or audio links, used mainly for the production of broadcast programmes or private or public social or cultural events.
Inductive devices | Covers radio devices that use magnetic fields with inductive loop systems for near field communications and determination applications. This typically includes devices for car immobilisation, animal identification, alarm systems, cable detection, waste management, personal identification, wireless voice links, access control, proximity and metal sensors, anti-theft systems as well as RF anti-theft induction systems, data transfer to hand-held devices, automatic article identification, wireless control systems and automatic road tolling.
Reliable alarm devices | Covers radio devices that use radio communication support for indicating an alert to a system or a person, as a main functionality, at a distant location when a problem or a specific situation occurs. Radio alarms include social alarms and alarms for security and safety.
Medical data acquisition devices | Covers the transmission of non-voice data to and from non-implantable medical devices in order to monitor, diagnose and treat patients in healthcare facilities or in their homes as prescribed by duly authorised healthcare professionals.
PMR446 devices | Covers hand portable equipment (without base station or repeater use) carried on a person or manually operated, which uses integral antennas only in order to maximise sharing and minimise interference. PMR 446 equipment operates in short-range peer-to-peer mode and shall not be used as a part of infrastructure network nor as a repeater.
Radio determination devices | Covers radio devices used for determining the position, velocity and/or other characteristics of an object, or for obtaining information relating to these parameters. Radio determination equipment typically conducts measurements to obtain such characteristics. Radio determination devices exclude any kind of point-to-point or point-to-multipoint radio communications.
Radio frequency identification (RFID) devices | Covers tag/interrogator based radio communications systems, consisting of (i) radio devices (tags) attached to animate or inanimate items; and (ii) transmitter/receiver units (interrogators) which activate the tags and receive data back. Typical applications include the tracking and identification of items, for instance for the purpose of electronic article surveillance (EAS), and collecting and transmitting data relating to the items to which tags are attached, which may be either battery-less, battery assisted or battery powered. The responses from a tag are validated by its interrogator and passed to its host system.
Transport and traffic telematics devices | Covers radio devices that are used in the fields of transport (road, rail, water or air, depending on the relevant technical restrictions), traffic management, navigation, mobility management and in intelligent transport systems (ITS). Typical applications include interfaces between different modes of transport, communication between vehicles (e.g. car to car), between vehicles and fixed locations (e.g. car to infrastructure) as well as communication from and to users.
Wideband data transmission devices | Covers radio devices that use wideband modulation techniques to access the spectrum. Typical uses include wireless access systems such as radio local area networks (WAS/RLAN) or wideband SRD in data networks.
Band No | Frequency band | Category of short-range devices | Transmit power limit / field strength limit / power density limit | Additional parameters (channelling and/or channel access and occupation rules) | Other usage restrictions | Implementation deadline
1 | 9-59,750 kHz | Inductive devices | 72 dBμA/m at 10 metres | | | 1 July 2014
90 | 9-148 kHz | Radio determination devices |
46 dBμA/m at 10 metres at a reference of 100 Hz, outside the Nuclear Magnetic Resonance (NMR) device.
Magnetic field strength descending 10 dB/decade above 100 Hz.
For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. | 1 July 2022
2 | 9-315 kHz | Active medical implant devices | 30 dBμA/m at 10 metres | Duty cycle ≤ 10 % | | 1 July 2014
3 | 59,750-60,250 kHz | Inductive devices | 42 dBμA/m at 10 metres | | | 1 July 2014
4 | 60,250-74,750 kHz | Inductive devices | 72 dBμA/m at 10 metres | | | 1 July 2014
5 | 74,750-75,250 kHz | Inductive devices | 42 dBμA/m at 10 metres | | | 1 July 2014
6 | 75,250-77,250 kHz | Inductive devices | 72 dBμA/m at 10 metres | | | 1 July 2014
7 | 77,250-77,750 kHz | Inductive devices | 42 dBμA/m at 10 metres | | | 1 July 2014
8 | 77,750-90 kHz | Inductive devices | 72 dBμA/m at 10 metres | | | 1 July 2014
9 | 90-119 kHz | Inductive devices | 42 dBμA/m at 10 metres | | | 1 July 2014
10 | 119-128,6 kHz | Inductive devices | 66 dBμA/m at 10 metres | | | 1 July 2014
11 | 128,6-129,6 kHz | Inductive devices | 42 dBμA/m at 10 metres | | | 1 July 2014
12 | 129,6-135 kHz | Inductive devices | 66 dBμA/m at 10 metres | | | 1 July 2014
13 | 135-140 kHz | Inductive devices | 42 dBμA/m at 10 metres | | | 1 July 2014
14 | 140-148,5 kHz | Inductive devices | 37,7 dBμA/m at 10 metres | | | 1 July 2014
15 | 148,5-5000 kHz [1] | Inductive devices |
15 dBμA/m at 10 metres in any bandwidth of 10 kHz.
Furthermore the total field strength is – 5 dΒμΑ/m at 10 metres for systems operating at bandwidths larger than 10 kHz.
1 July 2014
91 | 148-5000 kHz | Radio determination devices | – 15 dBμA/m at 10 metres outside the Nuclear Magnetic Resonance (NMR) device. | | For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. | 1 July 2022
16 | 315-600 kHz | Active medical implant devices | – 5 dB μA/m at 10 metres | Duty cycle ≤ 10 % | This set of usage conditions is only available for animal implant devices. | 1 July 2025
17 | 400-600 kHz | Radio Frequency Identification (RFID) devices | – 8 dBμA/m at 10 metres in any bandwidth of 10 kHz. Furthermore, the total field strength is – 5 dBμA/m at 10 metres for systems operating at bandwidths larger than 10 kHz. | Bandwidth ≥ 30 kHz | | 1 July 2025
85 | 442,2-450,0 kHz | Non-specific short-range devices | 7 dBμA/m at 10 metres | Channel spacing ≥ 150 Hz | This set of usage conditions is only available for person detection and collision avoidance devices. | 1 January 2020
18 | 456,9-457,1 kHz | Non-specific short-range devices | 7 dBμA/m at 10 metres | | This set of usage conditions is only available for emergency detections of buried victims and valuable items devices. | 1 July 2014
19 | 984-7484 kHz | Transport and Traffic Telematics devices | 9 dBμA/m at 10 metres | Duty cycle ≤ 1 % | This set of usage conditions is only available for Eurobalise transmissions in the presence of trains using the 27090-27100 kHz band for telepowering pursuant to the conditions set for band 28. | 1 July 2014
20 | 3155-3400 kHz | Inductive devices | 13,5 dBμA/m at 10 metres | | | 1 July 2014
21 | 5000-30000 kHz [2] | Inductive devices |
20 dBμA/m at 10 metres in any bandwidth of 10 kHz.
Furthermore the total field strength is – 5 dΒμΑ/m at 10 metres for systems operating at bandwidths larger than 10 kHz.
1 July 2014
92 | 5000-30000 kHz | Radio determination devices | – 5 dBμA/m at 10 metres outside the Nuclear Magnetic Resonance (NMR) device. | | For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. | 1 July 2022
22 | 6765-6795 kHz | Inductive devices | 42 dBμA/m at 10 metres | | | 1 July 2014
23 | 7300-23000 kHz | Transport and Traffic Telematics devices | – 7 dBμA/m at 10 metres | Antenna requirements apply [8]. | This set of usage conditions is only available for Eurobalise transmissions in the presence of trains using the 27090-27100 kHz band for telepowering pursuant to the conditions set for band 28. | 1 July 2014
24 | 7400-8800 kHz | Inductive devices | 9 dBμA/m at 10 metres | | | 1 July 2014
25 | 10200-11000 kHz | Inductive devices | 9 dBμA/m at 10 metres | | | 1 July 2014
26 | 12500-20000 kHz | Active medical implant devices | – 7 dBμA/m at 10 metres in any bandwidth of 10 kHz | Duty cycle ≤ 10 % | This set of usage conditions is only available for indoor use by animal implant devices. | 1 July 2025
27a | 13553-13567 kHz | Inductive devices | 42 dBμA/m at 10 metres | Transmission mask and antenna requirements for all combined frequency segments apply [8], [9]. | | 1 January 2020
27b | 13553-13567 kHz | Radio Frequency Identification (RFID) devices | 60 dBμA/m at 10 metres | Transmission mask and antenna requirements for all combined frequency segments apply [8], [9]. | | 1 July 2014
27c | 13553-13567 kHz | Non-specific short-range devices | 10 mW e.r.p. | | | 1 July 2014
28 | 26957-27283 kHz | Non-specific short-range devices | 10 mW e.r.p. | | | 1 July 2014
29 | 26990-27000 kHz | Non-specific short-range devices | 100 mW e.r.p. |
Duty cycle ≤ 0,1 %
Model control devices [d] may operate without duty cycle restrictions.
1 July 2014
30 | 27040-27050 kHz | Non-specific short-range devices | 100 mW e.r.p. |
Duty cycle ≤ 0,1 %
Model control devices [d] may operate without duty cycle restrictions.
1 July 2014
31 | 27090-27100 kHz | Non-specific short-range devices | 100 mW e.r.p. |
Duty cycle ≤: 0,1 %
Model control devices [d] may operate without duty cycle restrictions.
1 July 2014
32 | 27140-27150 kHz | Non-specific short-range devices | 100 mW e.r.p. |
Duty cycle ≤ 0,1 %
Model control devices [d] may operate without duty cycle restrictions.
1 July 2014
33 | 27190-27200 kHz | Non-specific short-range devices | 100 mW e.r.p. |
Duty cycle ≤ 0,1 %
Model control devices [d] may operate without duty cycle restrictions.
1 July 2014
34 | 30-37,5 MHz | Active medical implant devices | 1 mW e.r.p. | Duty cycle ≤ 10 % | This set of usage conditions is only available for ultra-low power medical membrane implants for blood pressure measurements. | 1 July 2014
93 | 30-130 MHz | Radio determination devices | – 36 dBm e.r.p. outside the Nuclear Magnetic Resonance (NMR) device. | | For enclosed Nuclear Magnetic Resonance (NMR) applications [j]. | 1 July 2022
35 | 40,66-40,7 MHz | Non-specific short-range devices | 10 mW e.r.p. | | | 1 January 2018
36 | 87,5-108 MHz | Non-specific short-range devices | 50 nW e.r.p. | Bandwidth ≤ 200 kHz. | This set of usage conditions is only available for audio transmitters with analogue frequency modulation (FM). | 1 July 2025
37a | 169,4-169,475 MHz | Assistive Listening Devices (ALD) | 500 mW e.r.p. | | | 1 July 2025
37c | 169,4-169,475 MHz | Non-specific short-range devices | 500 mW e.r.p. |
Duty cycle ≤ 1,0 %
For metering devices [a], the duty cycle ≤ 10 %
1 July 2025
38 | 169,4-169,4875 MHz | Non-specific short-range devices | 10 mW e.r.p. | Duty cycle ≤ 0,1 % | | 1 January 2020
39a | 169,4875-169,5875 MHz | Assistive Listening Devices (ALD) | 500 mW e.r.p. | | | 1 July 2025
39b | 169,4875-169,5875 MHz | Non-specific short-range devices | 10 mW e.r.p. |
Duty cycle ≤ 0,001 %
Between 00:00h and 06:00h local time a duty cycle ≤ 0,1 % may be used.
1 January 2020
40 | 169,5875-169,8125 MHz | Non-specific short-range devices | 10 mW e.r.p. | Duty cycle ≤ 0,1 % | | 1 January 2020
82 | 173,965-216 MHz | Assistive Listening Devices (ALD) | 10 mW e.r.p. |
On a tuning range basis [5].
A threshold of 35 dBμV/m is required to ensure the protection of a DAB receiver located at 1,5 metres from the ALD device, subject to DAB signal strength measurements taken around the ALD operating site. The ALD device should operate under all circumstances at least 300 kHz away from the channel edge of an occupied DAB channel.
Requirements on techniques to access spectrum and mitigate interference apply [7].
1 July 2025
41 | 401-402 MHz | Active medical implant devices | 25 μW e.r.p. |
Bandwidth ≤ 100 kHz
Requirements on techniques to access spectrum and mitigate interference apply [7].
Alternatively, a duty cycle limit of 0,1 % applies.
This set of usage conditions is only available for systems specifically designed for the purpose of providing non-voice digital communications between active implantable medical devices and/or body-worn devices and other devices external to the human body used for transferring non-time-critical individual patient-related physiological information. | 1 July 2025
42 | 402-405 MHz | Active medical implant devices | 25 μW e.r.p. |
Bandwidth ≤ 300 kHz.
Other techniques to access spectrum or mitigate interference, including bandwidths greater than 300 kHz, can be used provided they ensure compatible operation with the other users and in particular with meteorological radiosondes [7].
1 July 2025
43 | 405-406 MHz | Active medical implant devices | 25 μW e.r.p. |
Bandwidth ≤ 100 kHz
Requirements on techniques to access spectrum and mitigate interference apply [7].
Alternatively, a duty cycle limit of 0,1 % applies.
This set of usage conditions is only available for systems specifically designed for the purpose of providing non-voice digital communications between active implantable medical devices and/or body-worn devices and other devices external to the human body used for transferring non-time-critical individual patient-related physiological information. | 1 July 2025
86 | 430-440 MHz | Medical data acquisition devices | – 50 dBm/100kHz e.r.p. power density but not exceeding a total power of – 40 dBm/10MHz (both limits are intended for measurement outside of the patient’s body) | | The set of usage conditions is only available for Ultra-Low Power Wireless Medical Capsule Endoscopy (ULP-WMCE) applications [h]. | 1 January 2020
44a | 433,05-434,79 MHz | Non-specific short-range devices | 1 mW e.r.p. | | | 1 July 2025
44b | 433,05-434,79 MHz | Non-specific short-range devices | 10 mW e.r.p. | Duty cycle ≤ 10 % | | 1 January 2020
45c | 434,04-434,79 MHz | Non-specific short-range devices | 10 mW e.r.p. | Duty cycle ≤ 100 % subject to bandwidth ≤ 25 kHz. | | 1 July 2025
83 | 446,0-446,2 MHz | PMR446 | 500 mW e.r.p. | Requirements on techniques to access spectrum and mitigate interference apply [7]. | | 1 January 2018
94 | 821,5-826 MHz | Audio PMSE devices |
100 mW e.i.r.p. for body-worn devices
20 mW e.i.r.p. for other devices
1 July 2025
95 | 826-832 MHz | Audio PMSE devices | 100 mW e.i.r.p. | | | 1 July 2025
87 | 862-863 MHz | Non-specific short-range devices | 25 mW e.r.p. |
Duty cycle ≤ 0,1 %
Bandwidth ≤ 350 kHz
1 January 2020
46a | 863-865 MHz | Non-specific short-range devices | 25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7].
Alternatively, a duty cycle ≤ 0,1 % applies.
1 January 2018
46b | 863-865 MHz | Audio PMSE devices | 10 mW e.r.p. | | This set of usage conditions is also available for personal cordless audio devices. | 1 July 2025
84 | 863-868 MHz | Wideband data transmission devices | 25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7].
Bandwidth > 600 kHz and ≤ 1 MHz
Duty cycle ≤ 10 % for network access points [g]
Duty cycle ≤ 2,8% otherwise
This set of usage conditions is only available for wideband SRD in data networks [g]. | 1 January 2018
47 | 865-868 MHz | Non-specific short-range devices | 25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7].
Alternatively, a duty cycle ≤ 1 % applies.
1 January 2020
47a | 865-868 MHz [6] | Radio Frequency Identification (RFID) devices |
Interrogator transmissions at 2 W e.r.p. only permitted within the channels centred at 865,7 MHz, 866,3 MHz, 866,9 MHz and 867,5 MHz
RFID interrogator devices placed on the market before the repeal date of EC Decision 2006/804/EC are “grandfathered”, i.e. they are continuously permitted to be used in line with the provisions set out in EC Decision 2006/804/EC before the repeal date.
Requirements on techniques to access spectrum and mitigate interference apply [7].
Bandwidth ≤ 200 kHz
1 January 2018
47b | 865-868 MHz | Non-specific short-range devices |
500 mW e.r.p.
Transmissions only permitted within the frequency ranges 865,6-865,8 MHz, 866,2-866,4 MHz, 866,8-867,0 MHz and 867,4-867,6 MHz,
Adaptive Power Control (APC) required. Alternatively other mitigation technique with at least an equivalent level of spectrum compatibility.
Requirements on techniques to access spectrum and mitigate interference apply [7].
Bandwidth ≤ 200 kHz
Duty cycle ≤ 10 % for network access points [g]
Duty cycle ≤ 2,5 % otherwise
This set of usage conditions is only available for data networks [g]. | 1 January 2018
48 | 868-868,6 MHz | Non-specific short-range devices | 25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7].
Alternatively, a duty cycle ≤ 1 % applies.
1 January 2020
49 | 868,6-868,7 MHz | Reliable alarm devices | 10 mW e.r.p. |
Bandwidth ≤ 25 kHz. The whole frequency band may also be used as a single channel.
Duty cycle ≤ 1 %
1 July 2025
50 | 868,7-869,2 MHz | Non-specific short-range devices | 25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7].
Alternatively, a duty cycle ≤ 0,1 % applies.
1 January 2020
51 | 869,2-869,25 MHz | Reliable alarm devices | 10 mW e.r.p. |
Channel spacing: 25 kHz.
Duty cycle ≤ 0,1 %
This set of usage conditions is only available for social alarm devices [b]. | 1 July 2014
52 | 869,25-869,3 MHz | Reliable alarm devices | 10 mW e.r.p. |
Bandwidth ≤ 25 kHz
Duty cycle ≤ 0,1 %
1 July 2025
53 | 869,3-869,4 MHz | Reliable alarm devices | 10 mW e.r.p. |
Bandwidth ≤ 25 kHz
Duty cycle ≤ 1 %
1 July 2025
54 | 869,4-869,65 MHz | Non-specific short-range devices | 500 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7].
Alternatively, a duty cycle ≤ 10 % applies.
1 January 2020
55 | 869,65-869,7 MHz | Reliable alarm devices | 25 mW e.r.p. |
Bandwidth ≤ 25 kHz
Duty cycle ≤ 10 %
1 July 2025
56a | 869,7-870 MHz | Non-specific short-range devices | 5 mW e.r.p. | | | 1 July 2025
56b | 869,7-870 MHz | Non-specific short-range devices | 25 mW e.r.p. |
Requirements on techniques to access spectrum and mitigate interference apply [7].
Alternatively, a duty cycle ≤ 1 % applies.
1 January 2020
96 | 1785-1804,8 MHz | Audio PMSE devices |
50 mW e.i.r.p. for body-worn devices or devices implementing Spectrum Scanning Procedure (SSP).
20 mW e.i.r.p. for other devices.
1 July 2025
57a | 2400-2483,5 MHz | Non-specific short-range devices | 10 mW e.i.r.p. | | | 1 July 2014
57b | 2400-2483,5 MHz | Radio determination devices | 25 mW e.i.r.p. | | | 1 July 2014
57c | 2400-2483,5 MHz | Wideband data transmission devices |
100 mW e.i.r.p. and 100 mW/100 kHz e.i.r.p. density applies when frequency hopping modulation is used.
10 mW/MHz e.i.r.p. density applies when other types of modulation are used.