This Regulation lays down ecodesign requirements for the placing on the market or putting into service of fans with an electric input power between 125 W and 500 kW (≥ 125 W and ≤ 500 kW) at their best efficiency point, including where they are integrated into other products.
This Regulation shall not apply to:
fan impellers mounted on the shaft of electric motors with the sole purpose of cooling the motor itself;
fans integrated into laundry and washer-dryers with maximum electric input power lower than or equal to 3 kW;
fans integrated into kitchen hoods with total maximum electric input power attributable to the fan(s) lower than 280 W;
fans with a best energy efficiency point at 8000 revolutions per minute or more;
jet fans with maximum electric input power lower than 750 W;
This Regulation shall not apply to fans that are specified to operate exclusively as follows and are specifically designed and marketed as such:
in potentially explosive atmospheres, as defined in Article 2, point (5), of Directive 2014/34/EU of the European Parliament and of the Council [Directive 2014/34/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to equipment and protective systems intended for use in potentially explosive atmospheres (OJ L 96, 29.3.2014, p. 309).];
for emergency use only, with regard to fire safety requirements as set out in Regulation (EU) No 305/2011 of the European Parliament and of the Council [Regulation (EU) No 305/2011 of the European Parliament and of the Council of 9 March 2011 laying down harmonised conditions for the marketing of construction products and repealing Council Directive 89/106/EEC (OJ L 88, 4.4.2011, p. 5).], capable of short-time duty operation of 1 hour or more at temperatures of 300 oC and above;
in nuclear installations, as defined in Article 3, point (1), of Council Directive 2009/71/Euratom [Council Directive 2009/71/Euratom of 25 June 2009 establishing a Community framework for the nuclear safety of nuclear installations (OJ L 172, 2.7.2009, p. 18).];
in military establishments (bunkers) and civil defence establishments (bomb shelters);
where operating temperatures of the gas being moved can be higher than 100 °C, or lower than – 40 °C, or both;
where operating ambient air temperatures for the motor driving the fan, if located outside the gas stream, can be higher than 60 °C, or lower than – 30 °C, or both;
with a supply voltage higher than 1000 V AC or higher than 1500 V DC;
for handling toxic, highly corrosive or flammable gases or vapours as referred to in Regulation (EC) No 1272/2008 of the European Parliament and of the Council [Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006 (OJ L 353, 31.12.2008, p. 1).];
for material transport, characterised by handling substances with a solid particle concentration of more than 10 mg/m3 and particles with an average size of at least 0,1 mm and a hardness of at least 2 on the Mohs scale, while having an average blade angle of 50° to 90°;
for handling gases containing biohazardous substances of risk groups 2, 3 and 4 as set out in Directive 2000/54/EC of the European Parliament and of the Council [Directive 2000/54/EC of the European Parliament and of the Council of 18 September 2000 on the protection of workers from risks related to exposure to biological agents at work (seventh individual directive within the meaning of Article 16(1) of Directive 89/391/EEC) (OJ L 262, 17.10.2000, p. 21).];
for handling gases containing carcinogens or mutagens as defined in Directive 2004/37/EC of the European Parliament and of the Council [Directive 2004/37/EC of the European Parliament and of the Council of 29 April 2004 on the protection of workers from the risks related to exposure to carcinogens or mutagens at work (Sixth individual Directive within the meaning of Article 16(1) of Council Directive 89/391/EEC) (OJ L 158, 30.4.2004, p. 50).];
for handling gases with a compressibility factor, rounded to the nearest second decimal, in the designated pressure and temperature range of the scope that is not equal to 1,00;
in cordless or battery-powered equipment;
in handheld equipment whose weight is supported by hand during operation;
in hand-guided mobile equipment moved while in operation;
air circulating fans.