6 ANNEX III METHODS OF ANALYSIS TO CONTROL THE COMPOSITION OF FEED MATERIALS AND COMPOUND FEED, Regulation (EU) 2024/771

In forcesince 29 Feb 2024

This method makes it possible to determine the moisture content of feed. In case of feed containing volatile substances, such as organic acids, it is to be observed that also a significant number of volatile substances is determined together with the moisture content.

It does not cover the analysis of milk products as feed materials and compound feed composed predominantly of milk products, the analysis of animal and vegetable fats and oils or the analysis of the oil seeds and oleaginous fruit.

The determination of moisture content in oilseeds is to be determined by the method as provided for by EN ISO 665 Determination of moisture and volatile matter content, with the understanding that soybeans have to be ground before determination of moisture content.

The sample is desiccated under specified conditions which vary according to the nature of the feed. The loss in weight is determined by weighing. It is necessary to carry out preliminary drying when dealing with solid feed which has high moisture content.

3.1. Crusher of non-moisture-absorbing material which is easy to clean, allows rapid, even crushing without producing any appreciable heating, prevents contact with the outside air as far as possible and meets the requirements laid down in 4.1.1 and 4.1.2 (e.g. hammer or water-cooled micro-crushers, collapsible cone mills, slow motion or cog-wheeled crushers).

3.2. Analytical balance, accurate to 1 mg.

3.3. Dry containers of non-corrodible metal or of glass with lids ensuring airtight closure; working surface allowing the test sample to be spread at about 0,3 g/cm2.

3.4. Electrically heated isothermal oven (± 2 °C) properly ventilated and ensuring rapid temperature regulation [For the drying of cereals, flour, groats and meal, the oven must have a thermal capacity such that, when pre-set at 131 °C, it will return to that temperature in less than 45 minutes after the maximum number of test samples have been placed inside to dry simultaneously. Ventilation must be such that, when as many samples of common wheat as it can contain are dried for two hours, the results differ from those obtained after four hours of drying by less than 0,15 %.].

3.5. Adjustable electrically heated vacuum oven fitted with an oil pump and either a mechanism for introducing hot dried air or a drying agent (e.g. calcium oxide).

3.6. Desiccator with a thick perforated metal or porcelain plate, containing an efficient drying agent.

NB: The operations described in this section must be carried out immediately after opening the packages of samples. Analysis must be carried out at least in duplicate.

Take at least 50 g of the sample. If necessary, crush or divide in such a way as to avoid any variation in moisture content (see point 6).

Take at least 50 g of the sample. Grind into particles of which at least 50 % will pass through a 0,5 mm mesh sieve and will leave no more than 10 % reject on a 1 mm round-meshed sieve.

Take about 25 g of the sample, weigh to the nearest 10 mg, add an appropriate quantity of anhydrous sand weighed to the nearest 10 mg and mix until a homogeneous product is obtained.

Dry a container (point 3.3) with its lid in the oven set at 103 °C for 30 min +/- 1 min. Remove from the oven and allow to cool to ambient temperature in the desiccator (point 3.6).

Weigh the container with its lid to the nearest 1 mg. Weigh into the weighed container, to the nearest 1 mg, about 5 g of the sample and spread evenly. Place the container, without its lid, in the oven preheated to 103 °C. To prevent the oven temperature from falling unduly, introduce the container as rapidly as possible. Leave to dry for four hours reckoned from the time when the oven temperature returns to 103 °C. Open the oven, replace the lid on the container immediately, remove the latter from the oven, leave to cool for 30 to 45 minutes in the desiccator (point 3.6) and weigh to the nearest 1 mg.

For feed composed predominantly (> 50 %) of oils and fats of animal and plant origin, dry in the oven for an additional 30 minutes at 103 °C. The difference between the two weighings must not exceed 0,1 % of moisture.

Weigh the container with its lid to the nearest 0,5 mg. Weigh into the weighed container, to the nearest 1 mg, about 5 g of the crushed sample and spread evenly. Place the container, without its lid, in the oven preheated to 130 °C. To prevent the oven temperature from falling unduly, introduce the container as rapidly as possible. Leave to dry for two hours reckoned from the time when the oven temperature returns to 130 °C. Open the oven, replace the lid on the container immediately, remove the latter from the oven, leave to cool for 30 to 45 minutes in the desiccator (point 3.6) and weigh to the nearest 1 mg.

Weigh the container with its lid to the nearest 0,5 mg. Weigh into the weighed container, to the nearest 1 mg, about 5 g of the sample and spread evenly. Place the container, without its lid, in the vacuum oven (point 3.5) preheated to between 80 °C and 85 °C. To prevent the oven temperature from falling unduly, introduce the container as rapidly as possible.

Bring the pressure up to 100 Torr and leave to dry for four hours at this pressure, either in a current of hot, dry air or using a drying agent (about 300 g for 20 samples). In the latter instance, disconnect the vacuum pump when the prescribed pressure has been reached. Reckon drying time from the moment when the oven temperature returns to 80 °C to 85 °C. Carefully bring the oven back to atmospheric pressure. Open the oven, replace the lid on the container immediately, remove the container from the oven, leave to cool for 30 to 45 minutes in the desiccator (point 3.6) and weigh to the nearest 1 mg. Dry for an additional 30 minutes in the vacuum oven at 80 °C to 85 °C and reweigh. The difference between the two weighings must not exceed 0,1 % of moisture.

It is necessary to partially dry “wet” feeds with a mass fraction of less than 85 % dry matter (e.g. forages, total mixed rations, (non)-liquid feed) prior to fine grinding in order to analyse their stable substances; for unstable substances, partial drying is not possible.

Partial drying can be performed using either a forced-air oven or a microwave oven or by freeze drying. With the exception of partial drying by freeze drying, the aim is to dry the feed while keeping sample temperature below 60 °C so that chemical composition is minimally affected. Drying at temperatures greater than 60 °C causes chemical changes in the feed (e.g. protein degradation). The dried feed shall be equilibrated at room temperature for about 15 minutes before measuring partial dry matter so as to minimise the potential change in moisture that can occur during grinding and storage. Drying at temperatures lower than 60 °C does not remove all of the water from the feed; therefore, (initial) partial drying does not represent the total dry matter of the feed. Following drying, the subsample is ground and analysed for (final) dry matter of the partially dry sample (the remaining 3 % to 15 % moisture) when other chemical constituents are determined.

Therefore, a two-step procedure for determining dry matter is recommended. First determine the partial dry matter content (if less than 85 % dry matter), then determine the remaining dry matter content on a ground test sample and multiply partial dry matter by the remaining dry matter to determine the total dry matter content.

The moisture content (X), as a percentage of the sample, is calculated by using the following formulae:

Xm – m0m × 100

where:

minitial weight, in grammes, of the test sample,

m0weight, in grammes, of the dry test sample.

Xpm2 – m0 × m1

m2

m – m1 ×100

m

100 × 1 –m1 × m0m × m2

where:

minitial weight, in grammes, of the test sample,

m1weight, in grammes, of the test sample after preliminary drying,

m2weight, in grammes, of the test sample after crushing or grinding,

m0weight, in grammes, of the dry test sample.

The difference between the results of two parallel determinations carried out on the same sample shall not exceed 0,2 % of the absolute value of moisture, except for wet pet food and dog chews, where the difference shall not exceed 0,5 % of the absolute value of moisture.

If crushing proves necessary and if this is seen to alter the moisture content of the product, the results of the analysis of the components of the feed must be corrected on the basis of the moisture content of the sample in its initial state.

This method makes it possible to determine the water and volatile substances content of animal and vegetable fats and oils.

The sample is dried to constant weight (loss in weight between two successive weighings must be less than or equal to 1 mg) at 103 °C. The loss in weight is determined by weighing.

3.1. Flat-bottomed dish, of a corrosion-resistant material, 8 to 9 cm in diameter and approximately 3 cm high.

3.2. Thermometer with a strengthened bulb and expansion tube at the top end, graduated from approximately 80 °C to at least 110 °C, and approximately 10 cm in length.

3.3. Sand bath or electric hot-plate.

3.4. Desiccator, containing an efficient drying agent.

3.5. Analytical balance.

Weigh out to the nearest mg approximately 20 g of the homogenised sample into the dry, weighed dish (point 3.1) containing the thermometer (point 3.2). Heat on the sand bath or hot-plate (point 3.3), stirring continuously with the thermometer, so that the temperature reaches 90 °C in about 7 minutes.

Reduce the heat, watching the frequency with which bubbles rise from the bottom of the dish. The temperature must not exceed 105 °C. Continue to stir, scraping the bottom of the dish, until bubbles stop forming.

In order to ensure complete elimination of moisture, reheat several times to 103 °C ± 2 °C, cooling to 93 °C between successive heatings. Then leave to cool to room temperature in the desiccator (point 3.4) and weigh. Repeat this operation until the loss in weight between two successive weighings no longer exceeds 2 mg.

NB: An increase in the weight of the sample after repeated heating indicates an oxidation of the fat, in which case calculate the result from the weighing carried out immediately before the weight began to increase.

The moisture content (X), as a percentage of the sample, is given by the following formula:

Xm1 – m2 ×100

m

where:

mweight, in grammes, of the test sample;

m1weight, in grammes, of the dish with its contents before heating;

m2weight, in grammes, of the dish with its contents after heating.

Results lower than 0,05 % must be recorded as “lower than 0,05 %”.

The difference in moisture between the results of two parallel determinations carried out on the same sample must not exceed 0,1 %, in absolute value.

This method makes it possible to determine the crude protein content of feed on the basis of the nitrogen content, determined according to the Kjeldahl method [N content can be determined in all feeds but conversion factor of 6,25 for the calculation of crude protein content might not be applicable for insect feed materials (lower conversion factor) and certain pet food and blood plasma proteins (higher conversion factor).].

The sample is digested by sulphuric acid in the presence of a catalyst. The acid solution is made alkaline with sodium hydroxide solution. The ammonia is distilled and collected in a measured quantity of sulphuric acid, the excess of which is titrated with a standard solution of sodium hydroxide.

Alternatively, the liberated ammonia is distilled into an excess of boric acid solution, followed by titration with hydrochloric acid or sulphuric acid solution.

3.1. Potassium sulphate.

3.2. Catalyst: copper (II) oxide CuO or copper (II) sulphate pentahydrate, CuSO4 5H2O.

3.3. Granulated zinc.

3.4. Sulphuric acid, ρ20 = 1,84 g/ml.

3.5. Sulphuric acid, standard volumetric solution, c(H2SO4) = 0,25 mol/l.

3.6. Sulphuric acid, standard volumetric solution, c(H2SO4) = 0,10 mol/l.

3.7. Sulphuric acid, standard volumetric solution, c(H2SO4) = 0,05 mol/l.

3.8. Methyl red indicator; dissolve 300 mg of methyl red in 100 ml of ethanol, σ = 95-96 % (v/v).

3.9. Sodium hydroxide solution (Technical grade may be used) β = 40 g/100 ml (m/v: 40 %).

3.10. Sodium hydroxide, standard volumetric solution c(NaOH) = 0,25 mol/l.

3.11. Sodium hydroxide, standard volumetric solution c(NaOH) = 0,10 mol/l.

3.12. Granulated pumice stone, washed in hydrochloric acid and ignited.

3.13. Acetanilide (m.p. = 114 °C, N-content = 10,36 %).

3.14. Sucrose (nitrogen free).

3.15. Boric acid (H3BO3).

3.16. Methyl red indicator solution: dissolve 100 mg methyl red in 100 ml ethanol or methanol.

3.17. Bromocresol green solution: dissolve 100 mg bromocresol green in 100 ml ethanol or methanol.

3.18. Boric acid solution (10 g/l to 40 g/l depending on the apparatus used)

When colorimetric end-point detection is applied, methyl red and bromocresol indicators must be added to the boric acid solutions. If 1 litre of the boric acid solution is prepared, before adjusting to volume, 7 ml methyl red indicator solution (point 3.16) and 10 ml bromocresol green solution (point 3.17) shall be added.

Dependent on the water used, the pH of the boric acid solution might differ from batch to batch. The pH of the boric acid solution has to be between 4,3 and 4,7. Often an adjustment with a small volume of alkali is necessary to obtain a positive blank

Note: The addition of about 3 ml to 4 ml of NaOH (point 3.11) into 1 litre of 10 g/l boric acid usually gives good adjustments. Store the solution at room temperature and protect the solution from light and sources of ammonia fumes during storage.

3.19. Hydrochloric acid standard volumetric solution c(HCl) = 0,10 mol/l.

Note: Other concentrations of volumetric solutions (points 3.5, 3.6, 3.7, 3.10, 3.11 and 3.19) can be used, if this is corrected for in the calculations. The concentrations shall always be expressed to four decimal places.

Apparatus suitable for performing digestion, distillation and titration according to the Kjeldahl procedure.

Weigh 1 g of the sample to the nearest 0,001 g and transfer the sample to the flask of the digestion apparatus. Add 15 g of potassium sulphate (point 3.1), an appropriate quantity of catalyst (point 3.2) (0,3 to 0,4 g of copper (II) oxide or 0,9 to 1,2 g of copper (II) sulphate pentahydrate), 25 ml of sulphuric acid (point 3.4) and if required, a few granules of pumice stone (point 3.12) and mix.

Heat the flask moderately at first, swirling from time to time if necessary until the mass has carbonised and the foam has disappeared; then heat more intensively until the liquid is boiling steadily. Heating is adequate if the boiling acid condenses on the wall of the flask. Prevent the sides from becoming overheated and organic particles from sticking to them.

When the solution becomes clear and light green continue to boil for another two hours, then leave to cool.

Add carefully enough water to ensure complete dissolution of the sulphates. Allow to cool and then add a few granules of zinc (point 3.3), if required. Proceed according to point 5.2.1 or 5.2.2.

Place in the collecting flask of the distillation apparatus an exactly measured quantity of 25 ml of sulphuric acid (point 3.5) or (point 3.7) depending on the presumed nitrogen content. Add a few drops of methyl red indicator (point 3.8).

Connect the digestion flask to the condenser of the distillation apparatus and immerse the end of the condenser in the liquid contained in the collecting flask to a depth of at least 1 cm (see observation point 8.3). Slowly pour 100 ml of sodium hydroxide solution (point 3.9) into the digestion flask without loss of ammonia (see observation point 8.1). Heat the flask until the ammonia has distilled over.

Where titration of the ammonia content of the distillate is performed manually, the procedure mentioned below applies. Where the distillation unit is fully automated to include titration of the ammonia content of the distillate, follow the manufacturer’s instructions for operation of the distillation unit.

Place a collecting flask containing 25 ml to 30 ml of the boric acid solution (point 3.18) under the outlet of the condenser in such a way that the delivery tube is below the surface of the excess boric acid solution. Adjust the distillation unit to dispense 50 ml of sodium hydroxide solution (point 3.9). Operate the distillation unit in accordance with the manufacturer’s instructions and distil off the ammonia liberated by the addition of the sodium hydroxide solution. Collect distillate in the boric acid receiving solution. The amount of distillate (time of steam distillation) depends on the amount of nitrogen in the sample. Follow the instructions of the manufacturer.

Note: In a semi-automatic distillation unit, the addition of excess sodium hydroxide and the steam distillation are performed automatically.

Proceed according to point 5.3.1 or 5.3.2.

Titrate the excess sulphuric acid in the collecting flask with sodium hydroxide solution (point 3.10 or 3.11) depending on the concentration of the sulphuric acid used, until the end point is reached.

Titrate the contents of the collecting flask with the hydrochloric acid standard volumetric solution (point 3.19) or with the sulphuric acid standard volumetric solution (point 3.6) using a burette and read the amount of titrant used.

When colorimetric end-point detection is applied, the end-point is reached at the first trace of pink colour in the contents. Estimate the burette reading to the nearest 0,05 ml. An illuminated magnetic stirrer plate or a photometric detector may aid visualisation of the end-point.

This can be done automatically using a steam distiller with automatic titration.

Follow the manufacturers’ instructions for operation of the specific distiller or distiller/titrator.

Note: When an automatic titration system is used, titration begins immediately after distillation starts and the 1 % boric acid solution (point 3.18) is used.

Where a fully automatic distillation unit is employed, the automatic titration of the ammonia can also be carried out with end-point detection using a potentiometric pH system.

In this case an automatic titrator with a pH-meter is used. The pH-meter shall be calibrated properly in the range of pH 4 to pH 7 following normal laboratory pH-calibration procedures.

The pH end-point of the titration is reached at pH 4,6, being the steepest point in the titration curve (inflection point).

To confirm that the reagents are free from nitrogen, carry out a blank test (digestion, distillation and titration) using 1 g of sucrose (point 3.14) in place of the sample.

Calculations are performed according to point 6.1 or 6.2.

The content of crude protein, expressed as a percentage by weight, is calculated according to the following formula:

V0 – V1 × c ×0,014× 100 ×6,25

m

where:

V0is the volume (ml) of NaOH (point 3.10 or 3.11) used in the blank test

V1is the volume (ml) of NaOH (point 3.10 or 3.11) used in the sample titration

cis the concentration (mol/l) of sodium hydroxide (point 3.10 or 3.11)

mis the weight (g) of sample.

The content of crude protein, expressed as a percentage by weight, is calculated according to the following formula:

V1 – V0 × c ×1,4×6,25

m

where:

mis the weight (g) of the test portion

cis the concentration (mol/l) of the standard volumetric solution of the hydrochloric acid (point 3.19)

V0is the volume (in ml) of hydrochloric acid used for the blank test

V1is the volume (in ml) of hydrochloric acid used for the test portion.

The content of crude protein, expressed as a percentage by weight, is calculated according to the following formula:

V1 – V0 × c ×2,8×6,25

m

where:

mis the weight (g) of the test portion

cis the concentration (mol/l) of the standard volumetric solution of sulphuric acid (point 3.6)

V0is the volume (in ml) of sulphuric acid (point 3.6) used for the blank test

V1is the volume (in ml) of sulphuric acid (point 3.6) used for test portion.

The difference between the results of two parallel determinations carried out on the same sample must not exceed:

0,4 % in absolute value, for crude protein contents of less than 20 %,

2,0 % relative to the higher value, for crude protein contents from 20 % to 40 %,

0,8 % in absolute value, for crude protein contents of more than 40 %.

The difference between the results of two determinations carried out on the same sample in different laboratories must not exceed:

1,8 % in absolute value, for crude protein contents of less than 20 %,

9,0 % relative to the higher value, for crude protein contents from 20 % to 40 %,

3,6 % in absolute value, for crude protein contents of more than 40 %.

Carry out the analysis (digestion, distillation and titration) on an appropriate quantity of acetanilide (point 3.13) (e.g. 0,2 to 0,3 g) in the presence of 1 g of sucrose (point 3.14); 1 g acetanilide consumes 14,80 ml of sulphuric acid (point 3.5). Recovery must be at least 99 %.

8.1. Apparatus may be of the manual, semi-automatic or automatic type. If the apparatus requires transference between the digestion and distillation steps, this transfer must be carried out without loss. If the flask of the distillation apparatus is not fitted with a dropping funnel, add the sodium hydroxide immediately before connecting the flask to the condenser, pouring the liquid slowly down the side.

8.2. If the digest solidifies, recommence the determination using a larger amount of sulphuric acid (point 3.4) than that specified in point 5.1.

8.3. For products with a low nitrogen content, the volume of sulphuric acid (point 3.7) to be placed in the collecting flask may be reduced, if necessary, to 10 or 15 ml and made up to 25 ml with water.

8.4. For routine analysis, alternative methods of analysis can be applied for the determination of crude protein but the Kjeldahl method described in this Part C is the reference method. The equivalence of the results obtained with the alternative method (e.g. DUMAS) compared to the reference method must be demonstrated for each matrix individually. As the results obtained with an alternative method, even after having verified the equivalency, might deviate slightly from the results obtained with the reference method, it is necessary to mention in the analytical report the method of analysis used for the determination of crude protein.

This method makes it possible to determine the level of urea used as feed additive in ruminant feed.

The sample is suspended in water with a clarifying agent. The suspension is filtered. The urea content of the filtrate is determined after the addition of 4-dimethylaminobenzaldehyde (4-DMAB) by measuring the optical density at a wavelength of 420 nm.

3.1. Solution of 4-dimethylaminobenzaldehyde: dissolve 1,6 g of 4-DMAB in 100 ml of 96 % ethanol and add 10 ml of hydrochloric acid (ρ20 1,19 g/ml). This reagent keeps for a maximum period of two weeks.

This article is long: the rest is at the official publication.