The analytical techniques reported belonged to two distinct categories: (1) Infra-Red (IR) or Raman optical micro-spectroscopy methods, which can identify the type of polymer in individual particles and additionally provide information on its size and shape, and (2) Thermo-analytical methods, which can identify the polymers contained in a sample and quantify the total mass of each polymer type. In the case of IR or Raman optical micro-spectroscopy methods, identification of polymer compositions requires a comparison of particle spectra with a library of spectra from known polymers. The lowest detectable particle size which still allows polymer identification, depends on the methods (IR or Raman) and the instrument used. In the case of thermo-analytical methods, identification of polymer compositions requires a comparison of their thermal decomposition products with a library of mass spectra of pyrolysis products from known polymers. Quantification of identified polymers requires a calibration for each polymer. Thermo-analytical methods alone are unable to provide information on particle numbers, size or shape. Thermo-analytical methods have no intrinsic lower detection limit for particle size, but are limited by the minimum mass detection levels.
Recital 7, Decision_act (EU) 2024/1441
In forcesince 11 Mar 2024