1.1. The presence of the specified pest is suspected where a positive result is obtained in the first detection test performed on the specified plant.
For symptomatic plant material, the first detection test may be a selective isolation.
1.2. The presence of the specified pest is confirmed on symptomatic samples of the specified plants in the following cases:
where the first detection test is a selective isolation resulting in colonies with typical morphology: positive results are obtained in two identification tests;
where the first detection test is another test than a selective isolation:
positive results are obtained in two identification tests after the sample has been subject to selective isolation;
positive results are obtained in a second detection test other than a selective isolation.
1.3. The presence of the specified pest is confirmed on asymptomatic samples of the specified plants in the following cases:
where a positive result is obtained in the second detection test provided that the first or the second detection test is a molecular (DNA-based) test (TaqMan® Real-time PCR or conventional PCR);
for samples taken in a Member State or in an area of a Member State where the specified pest is not known to occur and for samples which originate from another Member State: where a positive result is obtained in the second detection test in accordance with point (a) and positive results are obtained in two identification tests performed after the sample has been subject to selective isolation.
The detection tests shall be such as to consistently detect at least 104 cells/ml resuspended pellet.
The second detection test shall be based on different biological principles or different nucleotide regions than the first detection test.
The detection tests are the following:
immunofluorescence tests, as described in international diagnostic standards;
FISH test (van Beuningen et al. (1995) [van Beuningen, A.R., Derks, H., Janse, J.D. (1995). Detection and identification of Clavibacter michiganensis subsp. sepedonicus with special attention to fluorescent in situ hybridization (FISH) using a 16S rRNA targeted oligonucleotide probe. Züchtungs Forschung 1, pp. 266–269.]), as described in international diagnostic standards;
Isolation as described in international diagnostic standards. One of the following two options shall be performed:
direct isolation on semi-selective (or non-selective) growth media, as described in international diagnostic standards;
after enrichment through the bioassay, isolation as described in international diagnostic standards;
conventional PCR test using the primers of Pastrik (2000) [Pastrik, K.H. (2000). Detection of Clavibacter michiganensis subsp. sepedonicus in potato tubers by multiplex PCR with coamplification of host DNA. European Journal of Plant Pathology, 106, pp. 155–165.], as described in international diagnostic standards;
TaqMan® Real-time PCR tests using primers and probes of:
Schaad et al. (1999) [Schaad, W., Berthier-Schaad, Y., Sechler, A., Knorr, D (1999). Detection of Clavibacter michiganensis subsp. sepedonicus in potato tubers by BIOPCR and an automated real-time fluorescence detection system. Plant Disease 83, pp. 1095–1100.], as described in international diagnostic standards;
Vreeburg et al. (2018) [Vreeburg, R., Zendman, A., Pol A., Verheij, E., Nas, M., Kooman-Gersmann, M. (2018). Validation of four real-time TaqMan PCRs for the detection of Ralstonia solanacearum and/or Ralstonia pseudosolanacearum and/or Clavibacter michiganensis subsp. sepedonicus in potato tubers using a statistical regression approach. EPPO Bulletin 48, pp. 86–96.] (so-called NYtor test), as described in international diagnostic standards;
Gudmestad et al. (2009) as adapted by Vreeburg et al. (2018) 4, as described in international diagnostic standards;
Massart et al. (2014) [Massart, S., Nagy, C., Jijakli, M.H. (2014). Development of the simultaneous detection of Ralstonia solanacearum race 3 and Clavibacter michiganensis subsp. sepedonicus in potato tubers by a multiplex real-time PCR assay. European Journal of Plant Pathology 138, pp. 29–37.], as described in international diagnostic standards.
The identification tests are the following:
an immunofluorescence test, as described in international diagnostic standards;
conventional PCR test (Pastrik (2000)), as described in international diagnostic standards;
TaqMan® Real-time PCR tests using primers and probes of:
Schaad et al. (1999), as described in international diagnostic standards;
Vreeburg et al. (2018) (so-called NYtor test), as described in international diagnostic standards;
Gudmestad et al. (2009) as adapted by Vreeburg et al. (2018), as described in international diagnostic standards;
Massart et al. (2014), as described in international diagnostic standards;
DNA barcoding, as described in international diagnostic standards;
MALDI-TOF MS (Zaluga et al. (2011) [Zaluga, J., Heylen, K., Van Hoorde, K., Hoste, B., Vaerenbergh, J., Maes, M., De Vos, P. (2011). GyrB sequence analysis and MALDI-TOF MS as identification tools for plant pathogenic Clavibacter. Systematic and applied microbiology 34, 400-7. 10.1016/j.syapm.2011.05.001.]), as described in international diagnostic standards.
a Isolation can be used as the first or the second detection test. If the presence of the specified pest is suspected on the growth medium, colonies shall be purified to obtain pure cultures on which two identification tests shall be performed. Positive results in the two identification tests are required to confirm the presence of the pest.
b The third detection test shall be based on different biological principles or different nucleotide regions.
a Isolation shall not be used.
b The third detection test shall be based on different biological principles or different nucleotide regions. Isolation shall not be used.
c For the samples referred to in point (1.3)(b), confirmation of the specified pest presence after the second positive detection test requires isolation of the specified pest from the sample, followed by two positive identification tests.
The standard sample shall contain 200 tubers per test. The appropriate laboratory procedure to process the heel end cores to obtain the extract for detection of the specified pest is described in international diagnostic standards.
Detection of latent infections shall be carried out on composite samples of stem segments. The procedure may be applied for up to 200 stem parts from different plants in one sample. The appropriate laboratory procedure to disinfect and process the stem segments to obtain the extract for the detection of the specified pest is described in international diagnostic standards.
Sections of tissue shall be aseptically removed from the vascular ring in a tuber or from the vascular strands in stems of specified plants showing wilting symptoms. The appropriate laboratory procedure to process these tissues to obtain the extract for the detection of the specified pest is described in full detail in international diagnostic standards.