The method set out in this Annex seeks to determine the Δ9-tetrahydrocannabinol (hereinafter referred to as ‘THC content’ of varieties of hemp (Cannabis sativa L.). As appropriate, the method involves applying procedure A or B as described in this Annex.
The method is based on the quantitative determination of THC by gas chromatography (GC) after extraction with a suitable solvent.
Procedure A shall be used for checks on the production of hemp.
In accordance with Article 60 of Regulation (EU) 2021/2116, the Member State shall determine the minimum percentage of the on-the-spot checks, which shall cover at least 15 % of the areas declared for the production of hemp in accordance with Article 8 of Implementing Regulation (EU) 2022/1173.
Procedure B shall be used where a Member State introduces a system of prior approval for the cultivation of hemp.
In accordance with Article 60 of Regulation (EU) 2021/2116, the Member State shall determine the minimum percentage of the on-the-spot checks, which shall cover at least 10 % of the areas declared for the production of hemp in accordance with Article 8 of Implementing Regulation (EU) 2022/1173.
The samples shall be taken during the day following a systematic pattern to ensure that the sample is representative of the field, but excluding the edges of the crop.
In a standing crop of a given variety of hemp, a 30 cm part containing at least one female inflorescence of each plant selected shall be taken. Sampling shall be carried out during the period running from 20 days after the start of flowering to 10 days after the end of flowering.
Member States may authorise sampling to be carried out during the period from the start of flowering to 20 days after the start of flowering provided that, for each variety grown, other representative samples are taken in accordance with the first paragraph during the period from 20 days after the start of flowering to 10 days after the end of flowering.
For hemp cultivated as catch crop, in the absence of female inflorescences, the top 30 cm of the plant stem shall be taken. In that case sampling shall be carried out just before the end of the vegetation period, once the leaves begin presenting the first signs of yellowing, however no later than the onset of a forecast period of frost.
In a standing crop of a given variety of hemp, the upper third of each plant selected shall be taken. Sampling shall be carried out during the 10 days following the end of flowering or, for hemp cultivated as catch crop, in the absence of female inflorescences, just before the end of the vegetation period, once the leaves begin presenting the first sign of yellowing, but no later than the onset of a forecast period of frost. In the case of dioecious varieties, only female plants shall be taken.
Procedure A: the sample shall comprise parts of 50 plants per field.
Procedure B: the sample shall comprise parts of 200 plants per field.
Each sample shall be placed in a fabric or paper bag, without crushing it, and be sent to the laboratory for analysis.
Member States may provide for a second sample to be collected for counter-analysis, if required, to be kept either by the producer or by the body responsible for the analysis.
Drying of the samples shall begin as soon as possible and, in any case, within 48 hours using any method below 70 °C.
Samples shall be dried to a constant weight and to a moisture content of between 8 % and 13 %.
After drying, the samples shall be stored without crushing them at below 25 °C in a dark place.
Stems and seeds over 2 mm in size shall be removed from the dried samples.
The dried samples shall be grinded to obtain a semi-fine powder (passing through a 1 mm mesh sieve).
The powder may be stored for 10 weeks at below 25 °C in a dark, dry place.
Δ9-tetrahydrocannabinol, pure for chromatographic purposes,
squalane, pure for chromatographic purposes, as an internal standard.
35 mg of squalane per 100 ml hexane.
100 mg of the powdered test sample shall be weighed, be placed in a centrifuge tube and 5 ml of extraction solution shall be added containing the internal standard.
The sample shall be placed in an ultrasound bath and be left for 20 minutes. It shall be centrifuged for 5 minutes at 3000 r.p.m. and then the supernatant THC solution shall be removed. The solution shall be injected into the chromatograph and a quantitative analysis shall be carried out.
Apparatus
gas chromatograph with a flame ionisation detector and a split/splitless injector,
column allowing good separation of cannabinoids, for example a glass capillary column 25 m long and 0,22 mm in diameter impregnated with a 5 % non-polar phenyl-methyl-siloxane phase.
Calibration ranges
At least three points for procedure A and five points for procedure B, including points 0,04 and 0,50 mg/ml THC in extraction solution.
Experimental conditions
The following conditions are given as an example for the column referred to in point (a):
oven temperature 260 °C,
injector temperature 300 °C,
detector temperature 300 °C.
Volume injected: 1 μl.
The findings shall be expressed to two decimal places in grams of THC per 100 grams of analytical sample dried to constant weight. A tolerance of 0,03 g per 100 g shall apply.
Procedure A: one determination per test sample.
However, where the result obtained is above the limit laid down in Article 4(4), second subparagraph, of Regulation (EU) 2021/2115, a second determination shall be carried out per analysis sample and the mean value of the two determinations shall be taken as the result.
Procedure B: the result shall correspond to the mean value of two determinations per test sample.