1 ANNEX Best available techniques (BAT) conclusions for surface treatment using organic solvents including preservation of wood and wood products with chemicals, Decision_act (EU) 2020/2009

In forcesince 22 Jun 2020

These BAT conclusions concern the following activities specified in Annex I to Directive 2010/75/EU:

6.7: Surface treatment of substances, objects or products using organic solvents, in particular for dressing, printing, coating, degreasing, waterproofing, sizing, painting, cleaning or impregnating, with an organic solvent consumption capacity of more than 150 kg per hour or more than 200 tonnes per year.

6.10: Preservation of wood and wood products with chemicals with a production capacity exceeding 75 m3 per day other than exclusively treating against sapstain.

6.11: Independently operated treatment of waste water not covered by Directive 91/271/EEC provided that the main pollutant load originates from activities specified in point 6.7 or 6.10 of Annex I to Directive 2010/75/EU.

These BAT conclusions also cover the combined treatment of waste water from different origins provided that the main pollutant load originates from the activities specified in point 6.7 or 6.10 of Annex I to Directive 2010/75/EU and that the waste water treatment is not covered by Council Directive 91/271/EEC [Council Directive 91/271/EEC of 21 May 1991 concerning urban waste-water treatment (OJ L 135, 30.5.1991, p. 40).].

These BAT conclusions do not address the following:

For surface treatment of substances, objects or products using organic solvents:

Waterproofing of textiles by means other than the use of a solvent-based continuous film. This may be covered by the BAT conclusions for the textiles industry (TXT).

Printing, sizing and impregnation of textiles. This may be covered by the BAT conclusions for the textiles industry (TXT).

Lamination of wood-based panels.

Conversion of rubber.

Manufacturing of coating mixtures, varnishes, paints, inks, semiconductors, adhesives or pharmaceutical products.

On-site combustion plants unless the hot gases generated are used for direct contact heating, drying or any other treatment of objects or materials. These may be covered by the BAT conclusions for large combustion plants (LCP) or by Directive 2015/2193/EU of the European Parliament and of the Council [Directive (EU) 2015/2193 of the European Parliament and of the Council of 25 November 2015 on the limitation of emissions of certain pollutants into the air from medium combustion plants (OJ L 313, 28.11.2015, p. 1).].

For preservation of wood and wood products with chemicals:

Chemical modification and hydrophobisation (e.g. using resins) of wood and wood products.

Sapstain treatment of wood and wood products.

Ammonia treatment of wood and wood products.

On-site combustion plants. These may be covered by the BAT conclusions for large combustion plants (LCP) or by Directive 2015/2193/EU.

Other BAT conclusions and reference documents which may be of relevance for the activities covered by these BAT conclusions are the following:

Economics and Cross-Media Effects (ECM).

Emissions from Storage (EFS).

Energy Efficiency (ENE).

Waste Treatment (WT).

Large Combustion Plants (LCP).

Surface Treatment of Metals and Plastics (STM).

Monitoring of Emissions to Air and Water from IED Installations (ROM).

For the purposes of these BAT conclusions, the following definitions apply:

General terms

Term used | Definition

Base coat | Paint which, when applied to a substrate, determines the colour and the effect (e.g. metallic, pearlescent).

Batch discharge | Discharge of a discrete, contained volume of water.

Clear coat | Coating material which, when applied to a substrate, forms a solid transparent film with protective, decorative or specific technical properties.

Combiline | Combination of hot-dip galvanising and coil coating in the same process line.

Continuous measurement | Measurement using an automated measuring system permanently installed on site for continuous monitoring of emissions, according to EN 14181.

Direct discharge | Discharge to a receiving water body without further downstream waste water treatment.

Emission factors | Coefficients that can be multiplied by known data such as plant/process data or throughput data to estimate emissions.

Existing plant | A plant that is not a new plant.

Fugitive emissions | Fugitive emissions as defined in Article 57(3) of Directive 2010/75/EU.

Grade B or C creosote | Types of creosote for which specifications are given in EN 13991.

Indirect discharge | Discharge which is not a direct discharge.

Major plant upgrade | A major change in the design or technology of a plant with major adjustments or replacements of the process and/or abatement technique(s) and associated equipment.

New plant | A plant first permitted on the site of the installation following the publication of these BAT conclusions or a complete replacement of a plant following the publication of these BAT conclusions.

Off-gas | The gas extracted from a process, piece of equipment or area which is either directed to treatment or discharged directly to air through a stack.

Organic compound | Organic compound as defined in Article 3(44) of Directive 2010/75/EU.

Organic solvent | Organic solvent as defined in Article 3(46) of Directive 2010/75/EU.

Plant |

All parts of an installation that carry out an activity listed in point 6.7 or 6.10 of Annex I to Directive 2010/75/EU and any other directly associated activities which have an effect on consumption and/or emissions.

Plants may be new plants or existing plants.

Primer coat | Paint formulated for use as a layer on a prepared surface, to provide good adhesion, protection of any layers below and filling of surface irregularities.

Sector | Any of the surface treatment activities that are part of activities listed in point 6.7 of Annex I to Directive 2010/75/EU and are referred to in Section 1 of these BAT conclusions.

Sensitive receptor |

Area which needs special protection, such as:

residential areas,

areas where human activities are carried out (e.g. neighbouring workplaces, schools, day-care centres, recreational areas, hospitals or nursing homes).

Solid mass input | The total mass of solids used as defined in Part 5, 3(a)(i) of Annex VII to Directive 2010/75/EU.

Solvent | ‘Solvent’ refers to ‘organic solvent’.

Solvent input | The total quantity of organic solvents used as defined in Part 7, 3(b) of Annex VII to Directive 2010/75/EU.

Solvent-based (SB) | Type of paint, ink or other coating material using solvent(s) as the carrier. For the preservation of wood and wood products, it refers to the type of treatment chemicals.

Solvent-based-mix (SB-mix) | Solvent-based coating where one of the coating layers is water-based (WB).

Solvent mass balance (SMB) | A mass balance exercise conducted at least once every year according to Part 7 of Annex VII to Directive 2010/75/EU.

Surface run-off water | Water from precipitation that flows over land or impervious surfaces, such as paved streets and storage areas, rooftops, etc. and does not soak into the ground.

Total emissions | The sum of fugitive emissions and emissions in waste gases as defined in Article 57(4) of Directive 2010/75/EU.

Treatment chemicals | Chemicals used in wood and wood products preservation such as biocides, chemicals used for waterproofing (e.g. oils, emulsions) and flame retardants. This also includes the carrier of active substances (e.g. water, solvent).

Valid hourly/half-hourly average | An hourly/half-hourly average is considered valid when there is no maintenance or malfunction of the automated measuring system.

Waste gases | Waste gases as defined in Article 57(2) of Directive 2010/75/EU.

Water-based (WB) | Type of paint, ink or other coating material in which water replaces all or part of the solvent content. For the preservation of wood and wood products, it refers to the type of treatment chemicals.

Wood preservation | Activities whose purpose is to protect wood and wood products from the damaging effects of fungi, bacteria, insects, water, weather or fire; to provide long-term conservation of structural integrity; and to improve the resistance of wood and wood products.

Pollutants and parameters

Term used | Definition

AOX | Adsorbable organically bound halogens, expressed as Cl, include adsorbable organically bound chlorine, bromine and iodine.

CO | Carbon monoxide.

COD | Chemical oxygen demand. Amount of oxygen needed for the total chemical oxidation of the organic matter to carbon dioxide using dichromate. COD is an indicator for the mass concentration of organic compounds.

Chromium | Chromium, expressed as Cr, includes all inorganic and organic chromium compounds, dissolved or bound to particles.

DMF | N,N-Dimethylformamide.

Dust | Total particulate matter (in air).

F- | Fluoride.

Hexavalent chromium | Hexavalent chromium, expressed as Cr(VI), includes all chromium compounds where the chromium is in the oxidation state +6 (dissolved or bound to particles).

HOI | Hydrocarbon oil index. The sum of compounds extractable with a hydrocarbon solvent (including long-chain or branched aliphatic, alicyclic, aromatic or alkyl-substituted aromatic hydrocarbons).

IPA | Isopropyl alcohol: propan-2-ol (also called isopropanol).

Nickel | Nickel, expressed as Ni, includes all inorganic and organic nickel compounds, dissolved or bound to particles.

NOX | The sum of nitrogen monoxide (NO) and nitrogen dioxide (NO2), expressed as NO2.

PAHs | Polycyclic aromatic hydrocarbons.

TOC | Total organic carbon, expressed as C (in water).

TVOC | Total volatile organic carbon, expressed as C (in air).

TSS | Total suspended solids. Mass concentration of all suspended solids (in water), measured via filtration through glass fibre filters and gravimetry.

VOC | Volatile organic compound as defined in Article 3(45) of Directive 2010/75/EU.

Zinc | Zinc, expressed as Zn, includes all inorganic and organic zinc compounds, dissolved or bound to particles.

For the purposes of these BAT conclusions, the following acronyms apply:

Acronym | Definition

BPR | Biocidal Products Regulation (Regulation (EU) No 528/2012 of the European Parliament and of the Council of 22 May 2012 concerning the making available on the market and use of biocidal products, OJ L 167, 27.6.2012, p. 1).

DWI | Drawn and wall ironed (a type of can in the metal packaging industry).

EMS | Environmental management system.

IED | Industrial Emissions Directive (2010/75/EU).

IR | Infrared.

LEL | Lower explosive limit – the lowest concentration (percentage) of a gas or vapour in air capable of producing a flash of fire in the presence of an ignition source. Concentrations lower than LEL are ‘too lean’ to burn. Also called lower flammable limit (LFL).

OTNOC | Other than normal operating conditions.

STS | Surface treatment using organic solvents.

UV | Ultraviolet.

WPC | Preservation of wood and wood products with chemicals.

The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection.

Unless otherwise stated, these BAT conclusions are generally applicable.

For total VOC emissions, the emission levels associated with the best available techniques (BAT-AELs) are given in these BAT conclusions:

as a specific emission load calculated as yearly averages by dividing the total emissions of VOCs (as calculated by the solvent mass balance) by a sector-dependent production input (or throughput) parameter; or

as a percentage of the solvent input, calculated as yearly averages as per Part 7, 3(b)(i) of Annex VII to Directive 2010/75/EU.

For fugitive VOC emissions, the emission levels associated with the best available techniques (BAT-AELs) are given in these BAT conclusions as a percentage of the solvent input, calculated as yearly averages as per Part 7, 3(b)(i) of Annex VII to Directive 2010/75/EU.

Emission levels associated with the best available techniques (BAT-AELs) and indicative emission levels for emissions in waste gases given in these BAT conclusions refer to concentrations, expressed as mass of emitted substance per volume of waste gas under the following standard conditions: dry gas, at a temperature of 273,15 K and a pressure of 101,3 kPa, without correction for oxygen content and expressed in mg/Nm3.

For averaging periods of BAT-AELs and indicative emission levels for emissions in waste gases, the following definitions apply.

[For any parameter where, due to sampling or analytical limitations and/or due to operational conditions, a 30-minute sampling/measurement and/or an average of three consecutive measurements is inappropriate, a more representative sampling/measurement procedure may be employed.]

Type of measurement | Averaging period | Definition

Continuous | Daily average | Average over a period of one day based on valid hourly or half-hourly averages.

Periodic | Average over the sampling period | Average value of three consecutive measurements of at least 30 minutes each.

Emission levels associated with the best available techniques (BAT-AELs) for emissions to water given in these BAT conclusions refer to concentrations (mass of emitted substance per volume of water), expressed in mg/l.

Averaging periods associated with the BAT-AELs refer to either of the following two cases:

in the case of continuous discharge, daily average values, i.e. 24-hour flow-proportional composite samples;

in the case of batch discharge, average values over the release duration taken as flow-proportional composite samples.

Time-proportional composite samples can be used provided that sufficient flow stability is demonstrated. Alternatively, spot samples may be taken, provided that the effluent is appropriately mixed and homogeneous. Spot samples are taken if the sample is unstable with respect to the parameter to be measured. All BAT-AELs for emissions to water apply at the point where the emission leaves the plant.

The environmental performance levels related to specific energy consumption refer to yearly averages calculated using the following equation:

where:

energy consumptionthe total amount of heat (generated by primary energy sources) and electricity consumed by the plant, as defined in the energy efficiency plan (see BAT 19 (a)), expressed in MWh/year;

activity ratetotal amount of products processed by the plant or plant throughput, expressed in the appropriate unit depending on the sector (e.g. kg/year, m2/year, vehicles coated/year).

The environmental performance levels related to specific water consumption refer to yearly averages calculated using the following equation:

where:

water consumptiontotal amount of water consumed by the activities carried out in the plant excluding recycled and reused water, cooling water used in once-through cooling systems, as well as water for domestic-type usage, expressed in l/year or m3/year;

activity ratetotal amount of products processed by the plant or plant throughput expressed in the appropriate unit depending on the sector (e.g. m2 of coated coil/year, vehicles coated/year, thousand cans/year).

The indicative levels related to the specific quantity of waste sent off site refer to yearly averages calculated using the following equation:

where:

waste quantity sent off site:total amount of waste sent off site by the plant, expressed in kg/year;

activity ratetotal amount of products processed by the plant or plant throughput expressed in vehicles coated/year.

(i)

commitment, leadership, and accountability of the management, including senior management, for the implementation of an effective EMS;

(ii)

an analysis that includes the determination of the organisation’s context, the identification of the needs and expectations of interested parties, the identification of characteristics of the installation that are associated with possible risks for the environment (or human health) as well as of the applicable legal requirements relating to the environment;

(iii)

development of an environmental policy that includes the continuous improvement of the environmental performance of the installation;

(iv)

establishing objectives and performance indicators in relation to significant environmental aspects, including safeguarding compliance with applicable legal requirements;

(v)

planning and implementing the necessary procedures and actions (including corrective and preventive actions where needed), to achieve the environmental objectives and avoid environmental risks;

(vi)

determination of structures, roles and responsibilities in relation to environmental aspects and objectives and provision of the financial and human resources needed;

(vii)

ensuring the necessary competence and awareness of staff whose work may affect the environmental performance of the installation (e.g. by providing information and training);

(viii)

internal and external communication;

(ix)

fostering employee involvement in good environmental management practices;

(x)

establishing and maintaining a management manual and written procedures to control activities with significant environmental impact as well as relevant records;

(xi)

effective operational planning and process control;

(xii)

implementation of appropriate maintenance programmes;

(xiii)

emergency preparedness and response protocols, including the prevention and/or mitigation of the adverse (environmental) impacts of emergency situations;

(xiv)

when (re)designing a (new) installation or a part thereof, consideration of its environmental impacts throughout its life, which includes construction, maintenance, operation and decommissioning;

(xv)

implementation of a monitoring and measurement programme; if necessary, information can be found in the Reference Report on Monitoring of Emissions to Air and Water from IED Installations;

(xvi) application of sectoral benchmarking on a regular basis;

(xvii) periodic independent (as far as practicable) internal auditing and periodic independent external auditing in order to assess the environmental performance and to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained;

(xviii) evaluation of causes of nonconformities, implementation of corrective actions in response to nonconformities, review of the effectiveness of corrective actions, and determination of whether similar nonconformities exist or could potentially occur;

(xix) periodic review, by senior management, of the EMS and its continuing suitability, adequacy and effectiveness;

(xx)

following and taking into account the development of cleaner techniques.

Specifically for surface treatment using organic solvents, BAT is also to incorporate the following features in the EMS:

(i)

Interaction with quality control and assurance as well as health and safety considerations.

(ii)

Planning to reduce the environmental footprint of an installation. In particular, this involves the following:

(a)

assessing the overall environmental performance of the plant (see BAT 2);

(b)

taking into account cross-media considerations, especially the maintenance of a proper balance between solvent emissions reduction and consumption of energy (see BAT 19), water (see BAT 20) and raw materials (see BAT 6);

(c)

reducing VOC emissions from cleaning processes (see BAT 9).

(iii)

The inclusion of:

(a)

a plan for the prevention and control of leaks and spillages (see BAT 5 (a));

(b)

a raw material evaluation system to use raw materials with low environmental impact and a plan to optimise the use of solvents in the process (see BAT 3);

(c)

a solvent mass balance (see BAT 10);

(d)

a maintenance programme to reduce the frequency and environmental consequences of OTNOC (see BAT 13);

(e)

an energy efficiency plan (see BAT 19 (a));

(f)

a water management plan (see BAT 20 (a));

(g)

a waste management plan (see BAT 22 (a));

(h)

an odour management plan (see BAT 23).

Regulation (EC) No 1221/2009 establishes the European Union eco-management and audit scheme (EMAS), which is an example of an EMS consistent with this BAT.

The level of detail and the degree of formalisation of the EMS will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have.

identify the process areas/sections/steps that represent the greatest contribution to the VOC emissions and energy consumption and the greatest potential for improvement (see also BAT 1);

identify and implement actions to minimise VOC emissions and energy consumption;

regularly (at least once every year) update the situation and follow up the implementation of the identified actions.

Technique | Description | Applicability

(a)

| Use of raw materials with a low environmental impact | As part of the EMS (see BAT 1), systematic evaluation of the adverse environmental impacts of the materials used (in particular substances that are carcinogenic, mutagenic and toxic to reproduction as well as substances of very high concern) and substitution by others with no or lower environmental and health impacts where possible, taking into consideration the product quality requirements or specifications. |

Generally applicable.

The scope (e.g. level of detail) and nature of the evaluation will generally be related to the nature, scale and complexity of the plant and the range of environmental impacts it may have, as well as to the type and quantity of materials used.

(b)

| Optimisation of the use of solvents in the process | Optimisation of the use of solvents in the process by a management plan (as part of the EMS (see BAT 1)) that aims to identify and implement necessary actions (e.g. colour batching, optimising spray pulverisation). | Generally applicable.

Technique | Description | Applicability

(a)

| Use of high-solids solvent-based paints/coatings/varnishes/inks/adhesives | Use of paints, coatings, liquid inks, varnishes and adhesives containing a low amount of solvents and an increased solids content. | The selection of the surface treatment techniques may be restricted by the activity type, the substrate type and shape, product quality requirements as well as the need to ensure that the materials used, coating application techniques, drying/curing techniques and off-gas treatment systems are mutually compatible.

(b)

| Use of water-based paints/coatings/inks/varnishes/adhesives | Use of paints, coatings, liquid inks, varnishes and adhesives where organic solvent is partially replaced by water.

(c)

| Use of radiation-cured inks/coatings/paints/varnishes/adhesives | Use of paints, coatings, liquid inks, varnishes and adhesives suitable to be cured by the activation of specific chemical groups by UV or IR radiation, or fast electrons, without heat and without emission of VOCs.

(d)

| Use of solvent-free two-component adhesives | Use of solvent-free two-component adhesive materials consisting of a resin and a hardener.

This article is long: the rest is at the official publication.