ANNEX III Measurement methods and calculations, Regulation (EU) 2019/2021

In forcesince 1 May 2021cited 1×

For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements and calculations shall be made using harmonised standards the reference numbers of which have been published for this purpose in the Official Journal of the European Union or other reliable, accurate and reproducible methods, which take into account the generally recognised state-of-the-art, and in line with the following provisions.

Where a parameter is declared pursuant to Article 4, its declared value shall be used by the manufacturer, importer or authorised representative for the calculations in this Annex.

In the absence of existing relevant standards and until the publication of the references of the relevant harmonised standards in the Official Journal, the transitional testing methods set out in Annex IIIa or other reliable, accurate and reproducible methods, which take into account the generally recognised state-of-the-art, shall be used.

Measurements and calculations shall meet the technical definitions, conditions, equations and parameters set out in this Annex. Electronic displays which can operate in both 2D and 3D modes shall be tested when they operate in 2D mode.

An electronic display which is split into two or more physically separate units, but placed on the market in a single package, shall, for checking the conformity with the requirements of this Annex, be treated as a single electronic display. Where multiple electronic displays that can be placed on the market separately are combined in a single system, the individual electronic displays shall be treated as single displays.

Measurements shall be made at an ambient temperature of 23 °C +/- 5 °C.

Measurements of the power demand referred to in Annex II, point A (1) shall fulfil all of the following conditions:

(a)

measurements of power demand (Pmeasured) shall be made in the normal configuration;

(b)

measurements shall be made using a dynamic broadcast-content video signal representing typical broadcast content for electronic displays in standard dynamic range (SDR). The measurement shall be the average power consumed over 10 consecutive minutes;

(c)

measurements shall be made after the electronic display has been in the off mode or, if an off-mode is not available, in standby mode, for a minimum of 1 hour immediately followed by a minimum of 1 hour in the on mode and shall be completed before a maximum of 3 hours in on-mode. The relevant video signal shall be displayed during the entire on mode duration. For electronic displays that are known to stabilise within 1 hour, these durations may be reduced if the resulting measurement can be shown to be within 2 % of the results that would otherwise be achieved using the durations described here;

(d)

where ABC is available, measurements shall be made with it switched off. If ABC cannot be switched off, then the measurements shall be performed in an ambient light condition of 100 lux measured at the ABC sensor.

Measurements of the peak white luminance referred to in Annex II, point B.3 shall be made:

(a)

with a luminance meter, detecting that portion of the screen exhibiting a full (100 %) white image, which is part of a ‘full screen test’ pattern that does not exceed the average picture level (APL) point where any power limiting or other irregularity occurs in the electronic display luminance drive system affecting the electronic display luminance;

(b)

without disturbing the luminance meter’s detection point on the electronic display whilst switching between any of the conditions referred to in Annex II, point B.3.

Measurements of Standard Dynamic Range, High Dynamic Range, screen luminance for Automatic Brightness Control, Peak White luminance ratio and other luminance measurements shall be made as detailed in Table 3a.

Notes

Pmeasured

Standard dynamic range (SDR) on-mode, ‘normal’

Power measurement notes

(See Annex IIIa for informative notes regarding the testing of Displays with a standardised DC input or a non-removable battery providing the primary power. For the purposes of these Transitional Measurement Methods a standardised DC input is solely one compatible with the various forms of USB power delivery.

Video Signals Notes

The 10-minute Dynamic Broadcast video sequence described in existing relevant standards shall be replaced with an updated 10-minute Dynamic Broadcast video sequence. This is available for download at: https://circabc.europa.eu/ui/group/1582d77c-d930-4c0d-b163-4f67e1d42f5b/library/23ab249b-6ebc-4f45-9b0e-df07bc61a596?p=1&n=10&sort=modified_DESC. Two files are available, in SD and HD. They are respectively titled ‘SD Dynamic Video Power.mp4’, and ‘HD Dynamic Video Power.mp4’. SD resolution is made available for the limited types of display that cannot accept or display higher resolution standards. The HD resolution file is used for all other display resolutions since this closely matches the average picture level (APL) of the current IEC HD dynamic broadcast dynamic test sequence described in existing relevant standards.

Upscaling from HD to higher native resolution shall be performed by the Unit Under Test (UUT) and not by an external device. Where upscaling has to be performed by an external device the full details of the device and the signal interface with the UUT shall be recorded.

The data signal from the downloaded file storage system to the UUT digital signal interface shall be confirmed to provide peak white and full black video levels. If the file playback system has special picture optimisation features (e.g. deep blacks or enhanced colour processing) these shall be disabled. For repeatability of measurement purposes, the details of the file storage and playback system shall be recorded as well as the type of digital interface with the UUT (e.g. HDMI, DVI etc.) The power measurement P measured is an average value from the full 10-minute length of the dynamic test sequence, taken with ABC disabled.

Pmeasured

High dynamic range (HDR)

on-mode ‘normal’

(auto mode switching to HDR)

No existing relevant standard is published so far.

Following the Pmeasured (SDR) dynamic test sequence measurement two HDR dynamic test sequences shall be played.

These 5-minute sequences are rendered in HD resolution only, in the common HDR standards of HLG and HDR10. Upscaling from HD to a higher native display resolution shall be performed by the UUT and not an external device. Where upscaling has to be performed by an external device the full details of the device and the signal interface with the UUT shall be recorded.

These files are available for download at: https://circabc.europa.eu/ui/group/1582d77c-d930-4c0d-b163-4f67e1d42f5b/library/38df374d-f367-4b72-93d6-3f48143ad661?p=1&n=10&sort=modified_DESC

and have identical programme content. The files are respectively titled ‘HDR-HLG Power.mp4’ and ‘HDR_HDR10 Power.mp4’

It is essential that the UUT switch to the HDR display mode is confirmed in the picture settings menu before power data is logged. The integrated power measurement for each sequence (Pav) shall be summed and halved for the calculation of the label HDR energy efficiency class and label HDR power declaration.

If the UUT cannot be tested in one of these HDR formats, this shall be noted and the power declared shall be the Pav measured for the HDR format that is supported.

An ABC allowance does not apply in HDR display mode.

Pmeasured HDR = 0.5 * (Pav HLG + Pav HDR10)

If one of these HDR display modes is not supported, the measured numerical value of (Pav HLG) or (Pav HDR10) as appropriate, shall be used for Label VII and Label VIII declarations.

Screen Luminance Measurement for automatic brightness control (ABC) control characteristics evaluation and any other peak white luminance measurement requirement. |

No existing relevant standards can be used.

A new variant of the ‘box and outline’ dynamic test pattern providing a dynamic format with colour shall be used for all peak white display luminance measurements and not the 3-bar black and white pattern.

A set of these variant dynamic test patterns, which combine the box and outline format and VESA L10 to L80 white measurement box format shall be used as described in Section 1.2.4. of Annex IIIa and are available for download at: https://circabc.europa.eu/ui/group/1582d77c-d930-4c0d-b163-4f67e1d42f5b/library/4f4b47a4-c078-49c4-a859-84421fc3cf5e?p=1&n=10&sort=modified_DESC. They are contained in the subfolders labelled SD, HD and UHD. Each subfolder contains eight peak white dynamic test patterns from L10 to L80. A resolution may be chosen according to the native resolution and signal compatibility of the UUT. The selection of a pattern with the appropriate resolution shall be based upon a) the minimum required white box dimensions for correct operation of the contact luminance measuring instrument and b) the fact that no power limiting effect exhibited by the UUT (large areas of white may result in a reduction of peak white levels). Any upscaling shall be performed by the UUT and not an external device. The data signal from the downloaded file storage system to the UUT digital signal interface shall be confirmed to provide peak white and full black video levels and have no other video enhancement processing (e.g. deep blacks / colour enhancement) Both the storage system and signal interface type shall be noted. For displays tested using a USB, or USB compatible data interface with the feature of power delivery, both the UUT and USB connected signal source shall operate from their own power source with the data path only connected..

Measurements related to ABC for ‘Allowances and adjustments for the purposes of the EEI calculation and functional requirements’ | The methodology for ABC ambient light source set-up and luminance control as specified in existing standards shall not be used for the purposes of ABC related measurements for this regulation. The methodology to be used is detailed in Section 1.2.5. of Annex IIIa.

Peak white luminance ratio |

No existing relevant standards can be used.

The ‘box and outline’ dynamic test pattern selected for the ABC peak white luminance measurements (Annex III.a Section 1.2.4) shall be used to measure the peak white luminance of the ‘normal configuration’ with ABC on. If this is less than 150 cd/m2 for monitors or 220 cd/m2 for other display products, then a further measurement shall be made of the peak white luminance of the brightest pre-set configuration in the user menu (not the shop configuration). ABC need not be on for the luminance ratio measurements but the status of the ABC (on or off) shall apply to both measurements. Where ABC is on, the illuminance shall be 100lux for both measurements. Care shall be taken to ensure that the dynamic test pattern selected for peak white luminance measurement in the ‘normal configuration’ does not cause luminance instability in the brightest pre-set configuration. A smaller peak white box pattern shall be selected for both measurements if instability occurs.

General notes |

The following test standards provide important supporting information for the specification of test equipment and the required testing conditions relevant to measurement and testing guidance given in this Annex.

EN 50564:2011

EN 50643:2018

EN 62087-1:2016

EN 62087- 2:2016

EN 62087-3:2016

EN IEC 62680 series of standards 2013 to 2020

IEC TR 63274 ED1:2020 (Advisory technical report on HDR testing requirements)