ANNEX VI Technical documentation, Regulation (EU) 2019/2016

In forcesince 30 Sep 2023cited 2×
1.

The technical documentation referred to in point 1(d) of Article 3 shall include the following elements:

(a)

a general description of the model allowing it to be unequivocally and easily identified;

(b)

references to the harmonised standards applied or other measurement standards used;

(c)

specific precautions to be taken when the model is assembled, installed, maintained or tested;

(d)

the values for the technical parameters set out in Table 7; these values are considered as the declared values for the purpose of the verification procedure in Annex IX;

(e)

the details and the results of calculations performed in accordance with Annex IV;

(f)

testing conditions if not described sufficiently in point (b);

(g)

equivalent models, if any, including model identifiers.

These elements shall also constitute the mandatory specific parts of the technical documentation that the supplier shall enter into the database, pursuant to point 5 of Article 12 of Regulation (EU) 2017/1369.

A general description of the refrigerating appliance model, sufficient for it to be unequivocally and easily identified:

Product specifications: |

General product specifications: |

Parameter | Value | Parameter | Value

Annual energy consumption (kWh/a) | x,xx | EEI (%) | x,x

Standard annual energy consumption (kWh/a) | x,xx | Combi parameter | x,xx

Temperature rise time (h) | x,xx | Load factor | x,x

Door heat loss factor | x,xxx | Climate class | [extended temperate/temperate/subtropical/tropical]

Anti-condensation heater type | [manual on-off/ambient/other/none] | Airborne acoustical noise emissions (dB(A) re 1 pW) | x

Additional product specifications for refrigerating appliances, except for low noise refrigerating appliances:

Parameter | Value |

Daily energy consumption at 32 °C (kWh/24h) | x,xxx

Additional product specifications for low noise refrigerating appliances:

Parameter | Value |

Daily energy consumption at 25 °C (kWh/24h) | x,xxx

Additional product specifications for wine storage appliances

Parameter | Value | Parameter | Value

Internal humidity (%) | [range] | Number of bottles | X

If the refrigerating appliance contains multiple compartments of the same type, the lines for these compartments shall be repeated. If a certain compartment type is not present, the compartment parameters’ values shall be ‘-’.

Compartment specifications:

Compartment parameters and values

Compartment type | Target temperature (°C) | Compartment volume (dm3 or l) | Freezing capacity (kg/24 h) | Thermodynamic parameter (rc) | Nc | Mc | Defrost factor (Ac) | Built-in factor (Bc)

Pantry | +17 | x,x | - | 0,35 | 75 | 0,12 | 1,00 | x,xx

Wine storage | +12 | x,x | - | 0,60 | 75 | 0,12 | 1,00 | x,xx

Cellar | +12 | x,x | - | 0,60 | 75 | 0,12 | 1,00 | x,xx

Fresh food | +4 | x,x | - | 1,00 | 75 | 0,12 | 1,00 | x,xx

Chill | +2 | x,x | - | 1,10 | 138 | 0,12 | 1,00 | x,xx

0-star or ice making | 0 | x,x | - | 1,20 | 138 | 0,15 | x,xx | x,xx

1-star | -6 | x,x | - | 1,50 | 138 | 0,15 | x,xx | x,xx

2-star | -12 | x,x | - | 1,80 | 138 | 0,15 | x,xx | x,xx

3-star | -18 | x,x | - | 2,10 | 138 | 0,15 | x,xx | x,xx

4-star | -18 | x,x | x,x | 2,10 | 138 | 0,15 | x,xx | x,xx

2-star section | -12 | x,x | - | 1,80 | 138 | 0,15 | x,xx | x,xx

Variable temperature compartment | X | x,x | x,x (for 4-star compartments) or - | x,xx | x | x,xx | x,xx | x,xx

The sum of the volumes of the chill compartment(s) and the unfrozen compartment(s)

[l or dm3]

x | | | | | |

The sum of the volumes of the frozen compartment(s) [l or dm3] | | x | | | | | |

2.

Where the information included in the technical documentation for a particular model has been obtained:

(a)

from a model that has the same technical characteristics relevant for the technical information to be provided but is produced by a different manufacturer; or

(b)

by calculation on the basis of design or extrapolation from another model of the same or a different manufacturer; or both.

The technical documentation shall include the details of such calculation, the assessment undertaken by the manufacturer to verify the accuracy of the calculation and, where appropriate, the declaration of identity between the models of different manufacturers.