ANNEX I, Regulation (EU) 2019/521

In forcesince 27 Mar 2019

Annex I to Regulation (EC) No 1272/2008 is amended as follows:

1.

Part 1 is amended as follows:

(a)

In section 1.1.2.2.2, Table 1.1 is replaced by the following:

[Or < 1 % where relevant, see 3.2.3.3.1.] [Or < 1 % where relevant, see 3.3.3.3.1.] [Or < 1 % where relevant, see 3.8.3.4.6.] [Or < 0,1 % where relevant, see 4.1.3.1.]

Hazard class | Generic cut-off values to be taken into account

Acute Toxicity:

Category 1-3

0,1 %

Category 4

1 %

Skin corrosion/Irritation | 1 %

Serious damage to eyes/eye irritation | 1 %

Specific target organ toxicity, single exposure, Category 3 | 1 %

Aspiration toxicity | 1 %

Hazardous to Aquatic Environment

Acute Category 1

0,1 %

Chronic Category 1

0,1 %

Chronic Category 2-4

1 %’

(b)

Section 1.1.3.7 is replaced by the following:

In the case of the classification of mixtures covered by sections 3.1, 3.2, 3.3, 3.4, 3.8 and 3.9, an aerosol form of a mixture shall be classified in the same hazard category as the tested non-aerosolised form of the mixture, provided that the added propellant does not affect the hazardous properties of the mixture upon spraying.’

(c)

Section 1.3.2.1 is replaced by the following:

‘1.3.2.1. If propane, butane and liquefied petroleum gas or a mixture containing these substances classified in accordance with the criteria of this Annex, is placed on the market in closed refillable cylinders or in non-refillable cartridges within the scope of EN 417 as fuel gases which are only released for combustion (current edition of EN 417, relating to “Non-refillable metallic gas cartridges for liquefied petroleum gases, with or without a valve, for use with portable appliances; construction, inspection, testing and marking”), these cylinders or cartridges need be labelled only with the appropriate pictogram and the hazard and precautionary statements concerning flammability.’

2.

Part 2 is amended as follows:

(a)

In section 2.1.1.1, point (c) is replaced by the following:

‘(c) substances, mixtures and articles not mentioned in points (a) and (b) above, which are manufactured with the view to producing a practical explosive or pyrotechnic effect.’

(b)

In section 2.1.2.2, point (f) is replaced by the following:

‘(f) Division 1.6 Extremely insensitive articles which do not have a mass explosion hazard:

articles which predominantly contain extremely insensitive substances or mixtures;

and which demonstrate a negligible probability of accidental initiation or propagation.’

(c)

In section 2.1.4.1, the third paragraph is replaced by the following:

‘Some explosive substances and mixtures are wetted with water or alcohols, diluted with other substances or dissolved or suspended in water or other liquid substances to suppress or reduce their explosives properties. They may be a candidate for classification as desensitised explosives (see Section 2.17).’

(d)

In section 2.1.4.1, figure 2.1.3 is replaced by the following:

(1)

See Chapter 3.3 of the UN RTDG, Model Regulations for details.’

(e)

Section 2.1.4.3 is amended as follows:

(i)

the introductory wording is replaced by the following:

‘2.1.4.3. The acceptance procedure for the hazard class “explosives” need not be applied if:’

(ii)

point (c) is replaced by the following:

‘(c) For an organic substance, or a homogenous mixture of organic substances, containing a chemical group (or groups) associated with explosive properties:

the exothermic decomposition energy is less than 500 J/g, or

the onset of exothermic decomposition is 500 °C or above

as indicated in Table 2.1.3.’

(iii)

Table 2.1.3 is added to 2.1.4.3 (c):

Decomposition energy

(J/g)

Decomposition onset temperature

(°C)

Apply acceptance procedure?

(Yes/No)

< 500 | < 500 | No

< 500 | ≥ 500 | No

≥ 500 | < 500 | Yes

≥ 500 | ≥ 500 | No

The exothermic decomposition energy may be determined using a suitable calorimetric technique (see section 20.3.3.3 of the UN RTDG, Manual of Tests and Criteria).’

(f)

In section 2.2 the title is replaced by the following:

(g)

Section 2.2.1 is replaced by the following:

2.2.1.1. Flammable gas means a gas or gas mixture having a flammable range with air at 20 °C and a standard pressure of 101,3 kPa.

2.2.1.2. A pyrophoric gas means a flammable gas that is liable to ignite spontaneously in air at a temperature of 54 °C or below.

2.2.1.3. A chemically unstable gas means a flammable gas that is able to react explosively even in the absence of air or oxygen.’

(h)

Sections 2.2.2.1 and 2.2.2.2 are replaced by the following:

‘2.2.2.1. A flammable gas is classified in Category 1A, 1B or 2 in accordance with Table 2.2.1. Flammable gases that are pyrophoric and/or chemically unstable are always classified in Category 1A.

Category | Criteria

1A | Flammable gas |

Gases, which at 20 °C and a standard pressure of 101,3 kPa are:

(a)

ignitable when in a mixture of 13 % or less by volume in air; or

(b)

have a flammable range with air of at least 12 percentage points regardless of the lower flammability limit

unless data show they meet the criteria for Category 1B

Pyrophoric gas | Flammable gases that ignite spontaneously in air at a temperature of 54 °C or below

Chemically unstable gas | A | Flammable gases which are chemically unstable at 20 °C and a standard pressure of 101,3 kPa

B | Flammable gases which are chemically unstable at a temperature greater than 20 °C and/or a pressure greater than 101,3 kPa

1B | Flammable gas |

Gases which meet the flammability criteria for Category 1A, but which are not pyrophoric, nor chemically unstable, and which have at least either:

(a)

a lower flammability limit of more than 6 % by volume in air; or

(b)

a fundamental burning velocity of less than 10 cm/s;

2 | Flammable gas | Gases, other than those of Category 1A or 1B, which, at 20 °C and a standard pressure of 101,3 kPa, have a flammable range while mixed in air.

NOTE 1: Aerosols shall not be classified as flammable gases. See Section 2.3.

NOTE 2: In the absence of data allowing classification into Category 1B, a flammable gas that meets the criteria for Category 1A is classified by default in Category 1A.

NOTE 3: Spontaneous ignition for pyrophoric gases is not always immediate, and there may be a delay.

NOTE 4: In the absence of data on its pyrophoricity, a flammable gas mixture shall be classified as a pyrophoric gas if it contains more than 1 % (by volume) of pyrophoric component(s).’

(i)

In section 2.2.3, Table 2.2.3 is replaced by the following:

Category 1A | Gases categorised as 1A meeting pyrophoric or unstable gas A/B criteria | Category 1B | Category 2

Pyrophoric gas | Chemically unstable gas | |

Category A | Category B

GHS Pictogram | | | | | | No pictogram

Signal Word | Danger | Danger | Danger | Danger | Danger | Warning

Hazard Statement | H220: Extremely flammable gas |

H220: Extremely flammable gas.

H232: May ignite spontaneously if exposed to air

H220: Extremely flammable gas.

H230: May react explosively even in the absence of air

H220: Extremely flammable gas.

H231: May react explosively even in the absence of air at elevated pressure and/or temperature

H221: Flammable gas | H221: Flammable gas

Precautionary Statement Prevention | P210 |

P210

P222

P280

P202

P210

P202

P210

P210 | P210

Precautionary Statement Response |

P377

P381

P377

P381

P377

P381

P377

P381

P377

P381

P377

P381

Precautionary Statement Storage | P403 | P403 | P403 | P403 | P403 | P403

Precautionary Statement Disposal | | | | | |

The classification procedure is set out in the following decision logic (see Figure 2.2.1).’

(j)

In section 2.2.3, the following paragraph is added after Table 2.2.2:

‘If a flammable gas or gas mixture is classified as pyrophoric and/or chemically unstable, then all relevant classification(s) shall be communicated on the safety data sheet as specified in Annex II of Regulation (EC) No 1907/2006, and the relevant hazard communication elements included on the label.’

(k)

In section 2.2.3, Figure 2.2.1 is replaced with the following:

(1)

In the absence of data on its pyrophoricity, a flammable gas mixture shall be classified as a pyrophoric gas if it contains more than 1 % (by volume) of pyrophoric component(s).

’

(l)

In section 2.2.3, Figure 2.2.2 is deleted.

(m)

Section 2.2.4 is amended as follows:

Section 2.2.4.1 is replaced by the following:

‘2.2.4.1. Flammability shall be determined by tests or, for mixtures where there are sufficient data available, by calculation in accordance with the methods adopted by ISO (see ISO 10156 as amended, “Gases and gas mixtures — Determination of fire potential and oxidising ability for the selection of cylinder valve outlets” and, if using fundamental burning velocity for Category 1B, see ISO 817 as amended “Refrigerants-Designation and safety classification, Annex C:- Method of test for burning velocity measurement of flammable gases”). Instead of the test apparatus according to ISO 10156 as amended, the test apparatus for the tube method according to clause 4.2 of EN 1839 as amended (Determination of explosion limits of gases and vapours) may be used.’

The following sections 2.2.4.2 and 2.2.4.3 are inserted:

‘2.2.4.2. Pyrophoricity shall be determined at 54 °C in accordance with either IEC 60079-20-1 ed1.0 (2010-01) “Explosive atmospheres – Part 20-1: Material characteristics for gas and vapour classification – Test methods and data” or DIN 51794 “Determining the ignition temperature of petroleum products”.

2.2.4.3. The classification procedure for pyrophoric gases need not be applied when experience in production or handling shows that the substance does not ignite spontaneously on coming into contact with air at a temperature of 54 °C or below. Flammable gas mixtures, which have not been tested for pyrophoricity and contain more than one percent pyrophoric components, shall be classified as a pyrophoric gas. Expert judgement on the properties and physical hazards of pyrophoric gases and their mixtures shall be used in assessing the need for classification of flammable gas mixtures containing one percent or less pyrophoric components. In this case, testing need only be considered if expert judgement indicates a need for additional data to support the classification process.’

(n)

Section 2.2.4.2 is renumbered as follows:

‘2.2.4.4.’

(o)

The text before paragraphs (a) to (d) in section 2.6.4.2 is replaced by the following:

‘2.6.4.2. In the case of mixtures [Up to now, the calculation method is validated for mixtures containing up to six volatile components. These components may be flammable liquids like hydrocarbons, ethers, alcohols, esters (except acrylates), and water. It is however not yet validated for mixtures containing halogenated, sulphurous, and/or phosphoric compounds as well as reactive acrylates.] containing known flammable liquids in defined concentrations, although they may contain non-volatile components e.g. polymers, additives, the flash point need not be determined experimentally if the calculated flash point of the mixture, using the method given in 2.6.4.3 below, is at least 5 °C [If the calculated flash point is less than 5 °C greater than the relevant classification criterion, the calculation method may not be used and the flash point shall be determined experimentally.’] greater than the relevant classification criterion and provided that:

(p)

Section 2.7.2.2 is replaced by the following:

‘2.7.2.2. Powders of metals or metal alloys shall be classified as flammable solids when they can be ignited and the reaction spreads over the whole length of the sample (100 mm) in 10 min or less.’

(q)

In section 2.12.2.1, Table 2.12.1 is replaced by the following:

Category | Criteria

1 | Any substance or mixture which reacts vigorously with water at ambient temperatures and demonstrates generally a tendency for the gas produced to ignite spontaneously, or which reacts readily with water at ambient temperatures such that the rate of evolution of flammable gas is equal to or greater than 10 litres per kilogram of substance over any one minute.

2 | Any substance or mixture which reacts readily with water at ambient temperatures such that the maximum rate of evolution of flammable gas is equal to or greater than 20 litres per kilogram of substance per hour, and which does not meet the criteria for Category 1.

3 | Any substance or mixture which reacts slowly with water at ambient temperatures such that the maximum rate of evolution of flammable gas is greater than 1 litre per kilogram of substance per hour, and which does not meet the criteria for Categories 1 and 2.

The test shall be performed on the substance or mixture in its physical form as presented. If, for example, for the purposes of supply or transport, the same chemical is to be presented in a physical form different from that which was tested and which is considered likely to materially alter its performance in a classification test, the substance must also be tested in the new form.’

(r)

The following section 2.17 is added:

2.17.1.1.

Desensitised explosives are solid or liquid explosive substances or mixtures which are phlegmatised to suppress their explosive properties in such a manner that they do not mass explode and do not burn too rapidly and therefore may be exempted from the hazard class “Explosives” (see also paragraph 3 in section 2.1.4.1) [Unstable explosives as defined in Section 2.1 can also be stabilised by desensitisation and consequently may be classified as desensitised explosives, provided all criteria of Section 2.17 are met. In this case the desensitised explosive shall be tested according to test series 3 (Part I of the UN RTDG, Manual of Tests and Criteria) because information about its sensitiveness to mechanical stimuli is likely to be important for determining conditions for safe handling and use. The results shall be communicated in the safety data sheet.]

2.17.1.2.

The hazard class of desensitised explosives comprises:

(a)

Solid desensitised explosives: explosive substances or mixtures, which are wetted with water or alcohols or are diluted with other substances, to form a homogeneous solid mixture to suppress their explosive properties.

NOTE: This includes desensitisation achieved by formation of hydrates of the substances.

(b)

Liquid desensitised explosives: explosive substances or mixtures, which are dissolved or suspended in water or other liquid substances, to form a homogeneous liquid mixture to suppress their explosive properties.

2.17.2.1.

Any explosive while in a desensitised state shall be considered in this class unless, in that state:

(a)

It is intended to produce a practical explosive or pyrotechnic effect;

(b)

It has a mass explosion hazard according to test series 6 (a) or 6 (b) or the corrected burning rate according to the burning rate test described in part V, subsection 51.4 of the UN RTDG, Manual of Tests and Criteria is greater than 1200 kg/min; or

(c)

The exothermic decomposition energy is less than 300 J/g.

NOTE 1: Substances or mixtures, which meet the criterion (a) or (b) in their desensitised state shall be classified as explosives (see Section 2.1). Substances or mixtures which meet the criterion (c) may fall within the scope of other physical hazard classes.

NOTE 2: The exothermic decomposition energy may be estimated using a suitable calorimetric technique (see section 20, sub-section 20.3.3.3 in Part II of the UN RTDG, Manual of Tests and Criteria).

2.17.2.2.

Desensitised explosives shall be classified and packaged for supply and use in one of the four categories of this class depending on the corrected burning rate (Ac) using the test “burning rate test (external fire)” described in Part V, sub-section 51.4 of the UN RTDG, Manual of Tests and Criteria, according to Table 2.17.1:

Category | Criteria

1 | Desensitised explosives with a corrected burning rate (AC) equal to or greater than 300 kg/min but not more than 1200 kg/min

2 | Desensitised explosives with a corrected burning rate (AC) equal to or greater than 140 kg/min but less than 300 kg/min

3 | Desensitised explosives with a corrected burning rate (AC) equal to or greater than 60 kg/min but less than 140 kg/min

4 | Desensitised explosives with a corrected burning rate (AC) less than 60 kg/min

Note 1: Desensitised explosives shall be prepared so that they remain homogeneous and do not separate during normal storage and handling, particularly if desensitised by wetting. The manufacturer/supplier shall give information in the safety data sheet about the shelf-life and instructions on verifying desensitisation. Under certain conditions the content of desensitising agent (e.g. phlegmatiser, wetting agent or treatment) may decrease during supply and use, and thus, the hazard potential of the desensitised explosive may increase. In addition, the safety data sheet shall include advice on avoiding increased fire, blast or projection hazards when the substance or mixture is not sufficiently desensitised.

Note 2: Explosive properties of desensitised explosives shall be determined by test series 2 of the UN RTDG, Manual of Tests and Criteria, and shall be communicated in the safety data sheet.

Note 3: For the purposes of storage, supply and use, desensitised explosives do not fall additionally within the scope of Sections 2.1 (explosives), 2.6 (flammable liquids) and 2.7 (flammable solids).

Label elements shall be used for liquid or solid substances or mixtures meeting the criteria for classification in this hazard class in accordance with Table 2.17.2.

Category 1 | Category 2 | Category 3 | Category 4

GHS Pictogram | | | |

Signal word | Danger | Danger | Warning | Warning

Hazard statement | H206 Fire, blast or projection hazard; increased risk of explosion if desensitising agent is reduced | H207 Fire or projection hazard; increased risk of explosion if desensitising agent is reduced | H207 Fire or projection hazard; increased risk of explosion if desensitising agent is reduced | H208: Fire hazard; increased risk of explosion if desensitising agent is reduced

Precautionary statement Prevention |

P210

P212

P230

P233

P280

P210

P212

P230

P233

P280

P210

P212

P230

P233

P280

P210

P212

P230

P233

P280

Precautionary Statement Response |

P370 +

P380+

P375

P370 +

P380+

P375

P370 +

P380+

P375

P371 +

P380 +

P375

Precautionary Statement Storage | P401 | P401 | P401 | P401

Precautionary Statement Disposal | P501 | P501 | P501 | P501

2.17.4.1.

The classification procedure for desensitised explosives does not apply if:

(a)

The substances or mixtures contain no explosives according to the criteria in Section 2.1; or

(b)

The exothermic decomposition energy is less than 300 J/g.

2.17.4.2.

The exothermic decomposition energy shall be determined using the explosive already desensitised (i.e.: the homogenous solid or liquids mixture formed by the explosive and the substance(s) used to suppress its explosive properties). The exothermic decomposition energy may be estimated using a suitable calorimetric technique (see Section 20, sub-section 20.3.3.3 in Part II of the UN RTDG, Manual of Tests and Criteria).’

3.

Part 3 is amended as follows:

(a)

Section 3.1.1.1 is replaced by the following:

‘3.1.1.1. Acute toxicity means serious adverse health effects (i.e., lethality) occurring after a single or short-term oral, dermal or inhalation exposure to a substance or mixture.’

(b)

In section 3.1.2.1, the introductory paragraph is replaced by the following:

‘3.1.2.1. Substances can be allocated to one of four hazard categories based on acute toxicity by the oral, dermal or inhalation route according to the numeric cut-off criteria as shown in the table below. Acute toxicity values are expressed as (approximate) LD50 (oral, dermal) or LC50 (inhalation) values or as acute toxicity estimates (ATE). While some in vivo methods determine LD50/LC50 values directly, other newer in vivo methods (e.g. using fewer animals) consider other indicators of acute toxicity, such as significant clinical signs of toxicity, which are used as a reference to assign the hazard category. Explanatory notes are shown following Table 3.1.1.’

(c)

In section 3.1.2.1 the title of Table 3.1.1 is replaced by the following:

(d)

Section 3.2.1.1 is replaced by the following:

‘3.2.1.1. Skin corrosion means the production of irreversible damage to the skin; namely, visible necrosis through the epidermis and into the dermis occurring after exposure to a substance or mixture.

Skin irritation means the production of reversible damage to the skin occurring after exposure to a substance or mixture.’

(e)

Section 3.3.1.1 is replaced by the following:

‘3.3.1.1. Serious eye damage means the production of tissue damage in the eye, or serious physical decay of vision, which is not fully reversible, occurring after exposure of the eye to a substance or mixture.

Eye irritation means the production of changes in the eye, which are fully reversible, occurring after the exposure of the eye to a substance or mixture.’

(f)

Section 3.4.1.1 is replaced by the following:

‘3.4.1.1. Respiratory sensitisation means hypersensitivity of the airways occurring after inhalation of a substance or a mixture.’

(g)

Section 3.4.1.2 is replaced by the following:

‘3.4.1.2. Skin sensitisation means an allergic response occurring after skin contact with a substance or a mixture.’

(h)

Section 3.4.2.1.3.1 is replaced by the following:

‘3.4.2.1.3.1. Data from appropriate animal studies [At present, recognised and validated animal models for the testing of respiratory hypersensitivity are not available. Under certain circumstances, data from animal studies may provide valuable information in a weight of evidence assessment.] which may be indicative of the potential of a substance to cause sensitisation by inhalation in humans [The mechanisms by which substances induce symptoms of asthma are not yet fully known. For preventative measures, these substances are considered respiratory sensitisers. However, if on the basis of the evidence, it can be demonstrated that these substances induce symptoms of asthma by irritation only in people with bronchial hyper-reactivity, they shall not be considered as respiratory sensitisers.’] may include:

(a)

measurements of Immunoglobulin E (IgE) and other specific immunological parameters, for example in mice;

(b)

specific pulmonary responses in guinea pigs.

(i)

In section 3.4.3.3.2, Table 3.4.6, Note 1 is replaced by the following:

This concentration limit for elicitation is used for the application of the special labelling requirements of section 2.8 of Annex II to protect already sensitised individuals. A SDS is required for the mixture containing a component at or above this concentration. For sensitising substances with a specific concentration limit, the concentration limit for elicitation shall be set at a tenth of the specific concentration limit.’

(j)

Section 3.5.1.1 is replaced by the following:

This article is long: the rest is at the official publication.