Art. 17b Regulation (EU) 2018/2067

Checking the application of derogations listed in Article 22a(1), second subparagraph, of Delegated Regulation (EU) 2019/331

In forcesince 14 May 2024cited 1×
1.

Where the implementation of recommendations referred to in Article 17a of this Regulation has not been completed, the verifier shall assess the operator’s evidence and check whether:

(a)

the energy efficiency recommendations referred to in Article 22a(1), second subparagraph, point (f), of Delegated Regulation (EU) 2019/331 were not issued in the first four years of the baseline period;

(b)

recommendations would not lead to energy savings within the system boundaries of the industrial process carried out at the installation;

(c)

the pay-back time referred to in Article 22a(1), second subparagraph, point (a), of Delegated Regulation (EU) 2019/331 exceeds three years;

(d)

the installation specific operating conditions, including planned or unplanned periods of maintenance, upon which the pay-back period was determined have not yet occurred;

(e)

the investment costs of the recommendations exceed the thresholds listed in Article 22a(1), second subparagraph, point (b) of Delegated Regulation (EU) 2019/331;

(f)

other measures have been implemented during or after the relevant baseline period which led to greenhouse gas emission reductions equivalent to those recommended by the energy audit report or a certified energy management system for the installation.

2.

Where the pay-back time referred to in Article 22a(1), second subparagraph, point (a), of Delegated Regulation (EU) 2019/331 is not specified in the energy audit report, the certified energy management system or a sworn declaration from the energy auditor, the verifier shall check:

(a)

the validity of the information used to determine the pay-back time;

(b)

the correct application of the method used to determine the pay-back time.

3.

For the purpose of assessing implementation of measures referred to in paragraph 1, point (f), the verifier shall check and confirm whether:

(a)

the operator has implemented the alternative measures and whether the implementation of those measures has been completed;

(b)

equivalent greenhouse gas emission reductions referred to in paragraph 1, point (f), have been achieved.