EHSR set out in Section 1.1.2 of Annex I to Directive 2006/42/EC regarding principles of safety integration requires that machinery must be designed and constructed to prevent putting persons at risk when operating the machinery under the conditions foreseen but also taking into account any reasonably foreseeable misuse.
Sweden indicated that the mounting brackets used for the safety interlocks were fastened with standard screws, which are easy to remove with standard tools, contrary to the principle of safety integration. This entails a risk of foreseeable misuse to defeat the mounting brackets instead using the interlocked doors.
The manufacturer stated that the reason was that the interlocked doors provide reasonable access that reduces the operator's motivation to defeat the interlocks when making extensive maintenance. Standard screws would reduce the risk of permanent damage to the guarding system or permanent removal of the guards.
Furthermore, Sweden explained that the fixed guards were mounted with quick-release fasteners, which entailed a risk that someone would open the fixed guard and use it for access instead of using the interlocked door. Sweden added that where the risk assessment shows that there should be a fixed guard, it must not be designed in such a way that it is an attractive option to access the machine by opening the fixed guard rather than by using the locked gate.
The manufacturer justified the use of quick-release fasteners to diminish the workers' motivation to defeat the fixed guards.
In its EC declaration of conformity, the manufacturer referred to the harmonised standard EN 1088:1995+A1:2007 but did not provide in the technical file a link between the reference of the harmonised standard and the respective EHSR as required by Annex VII to Directive 2006/42/EC. Despite this deficiency, Sweden linked the reference of that harmonised standard with the EHSR set out in Section 1.1.2 of Annex I to Directive 2006/42/EC.
Harmonised standard EN 1088+A2:2008 lays down safety technical requirements on machinery interlocking devices associated with guards and the principles for design and selection. Sweden refers to this standard to reinforce its justification on the manufacturer's lack of compliance with EHSRs 1.1.2. The manufacturer indicated that Section 5.7.1 Note 4 of the standard states that avoiding ‘defeat in a reasonably foreseeable manner’ needs to take into account the characteristics of the specific application and therefore based on the risk assessment. According to the manufacturer, the interlocked doors provide reasonable access that reduces the operator's motivation to defeat the interlocks.
The Commission considers that the mounting brackets and the fixed guards could be easily removed with standard tools, which entailed a reasonably foreseeable misuse of accessing the machine by bypassing the locked gates.
Thus, on the basis of the above arguments and taking into account the study confirming those arguments, it can be concluded that the EHSR set out in Section 1.1.2 of Annex I to Directive 2006/42/EC on principles of safety integration has not been fulfilled as regards the pinsetter machine and the supplementary kit.