1 ANNEX, Decision_act (EU) 2018/1147

In forcesince 10 Aug 2018

These BAT conclusions concern the following activities specified in Annex I to Directive 2010/75/EU, namely:

5.1. Disposal or recovery of hazardous waste with a capacity exceeding 10 tonnes per day involving one or more of the following activities:

(a)

biological treatment;

(b)

physico-chemical treatment;

(c)

blending or mixing prior to submission to any of the other activities listed in points 5.1 and 5.2 of Annex I to Directive 2010/75/EU;

(d)

repackaging prior to submission to any of the other activities listed in points 5.1 and 5.2 of Annex I to Directive 2010/75/EU;

(e)

solvent reclamation/regeneration;

(f)

recycling/reclamation of inorganic materials other than metals or metal compounds;

(g)

regeneration of acids or bases;

(h)

recovery of components used for pollution abatement;

(i)

recovery of components from catalysts;

(j)

oil re-refining or other reuses of oil;

5.3. (a) Disposal of non-hazardous waste with a capacity exceeding 50 tonnes per day involving one or more of the following activities, and excluding activities covered by Council Directive 91/271/EEC [Council Directive 91/271/EEC of 21 May 1991 concerning urban waste-water treatment (OJ L 135, 30.5.1991, p. 40).]:

(i)

biological treatment;

(ii)

physico-chemical treatment;

(iii)

pre-treatment of waste for incineration or co-incineration;

(iv)

treatment of ashes;

(v)

treatment in shredders of metal waste, including waste electrical and electronic equipment and end-of-life vehicles and their components.

(b)

Recovery, or a mix of recovery and disposal, of non-hazardous waste with a capacity exceeding 75 tonnes per day involving one or more of the following activities, and excluding activities covered by Directive 91/271/EEC:

(i)

biological treatment;

(ii)

pre-treatment of waste for incineration or co-incineration;

(iii)

treatment of ashes;

(iv)

treatment in shredders of metal waste, including waste electrical and electronic equipment and end-of-life vehicles and their components.

When the only waste treatment activity carried out is anaerobic digestion, the capacity threshold for this activity shall be 100 tonnes per day.

5.5. Temporary storage of hazardous waste not covered under point 5.4 of Annex I to Directive 2010/75/EU pending any of the activities listed in points 5.1, 5.2, 5.4 and 5.6 of Annex I to Directive 2010/75/EU with a total capacity exceeding 50 tonnes, excluding temporary storage, pending collection, on the site where the waste is generated.

6.11. Independently operated treatment of waste water not covered by Directive 91/271/EEC and discharged by an installation undertaking activities covered under points 5.1, 5.3 or 5.5 as listed above.

Referring to independently operated treatment of waste water not covered by Directive 91/271/EEC above, these BAT conclusions also cover the combined treatment of waste water from different origins if the main pollutant load originates from the activities covered under points 5.1, 5.3 or 5.5 as listed above.

These BAT conclusions do not address the following:

Surface impoundment.

Disposal or recycling of animal carcases or of animal waste covered by the activity description in point 6.5 of Annex I to Directive 2010/75/EU when this is covered by the BAT conclusions on the slaughterhouses and animal by-products industries (SA).

On-farm processing of manure when this is covered by the BAT conclusions for the intensive rearing of poultry or pigs (IRPP).

Direct recovery (i.e. without pretreatment) of waste as a substitute for raw materials in installations carrying out activities covered by other BAT conclusions, e.g.:

Direct recovery of lead (e.g. from batteries), zinc or aluminium salts or recovery of the metals from catalysts. This may be covered by the BAT conclusions for the non-ferrous metals industries (NFM).

Processing of paper for recycling. This may be covered by the BAT conclusions for the production of pulp, paper and board (PP).

Use of waste as fuel/raw material in cement kilns. This may be covered by the BAT conclusions for the production of cement, lime and magnesium oxide (CLM).

Waste (co-)incineration, pyrolysis and gasification. This may be covered by the BAT conclusions for waste incineration (WI) or the BAT conclusions for large combustion plants (LCP).

Landfill of waste. This is covered by Council Directive 1999/31/EC [Council Directive 1999/31/EC of 26 April 1999 on the landfill of waste (OJ L 182, 16.7.1999, p. 1).]. In particular, underground permanent and long-term storage (≥ 1 year before disposal, ≥ 3 years before recovery) are covered by Directive 1999/31/EC.

In situ remediation of contaminated soil (i.e. unexcavated soil).

Treatment of slags and bottom ashes. This may be covered by the BAT conclusions for waste incineration (WI) and/or the BAT conclusions for large combustion plants (LCP).

Smelting of scrap metals and metal-bearing materials. This may be covered by the BAT conclusions for non-ferrous metals industries (NFM), the BAT conclusions for iron and steel production (IS), and/or the BAT conclusions for the smitheries and foundries industry (SF).

Regeneration of spent acids and alkalis when this is covered by the BAT conclusions for ferrous metals processing.

Combustion of fuels when it does not generate hot gases which come into direct contact with the waste. This may be covered by the BAT conclusions for large combustion plants (LCP) or by Directive (EU) 2015/2193 of the European Parliament and of the Council [Directive (EU) 2015/2193 of the European Parliament and of the Council of 25 November 2015 on the limitation of emissions of certain pollutants into the air from medium combustion plants (OJ L 313, 28.11.2015, p. 1).].

Other BAT conclusions and reference documents which could be relevant for the activities covered by these BAT conclusions are the following:

Economics and cross-media effects (ECM);

Emissions from storage (EFS);

Energy efficiency (ENE);

Monitoring of emissions to air and water from IED installations (ROM);

Production of cement, lime and magnesium oxide (CLM);

Common waste water and waste gas treatment/management systems in the chemical sector (CWW);

Intensive rearing of poultry or pigs (IRPP).

These BAT conclusions apply without prejudice to the relevant provisions of EU legislation, e.g. the waste hierarchy.

For the purposes of these BAT conclusions, the following definitions apply:

[Directive 2008/98/EC of the European Parliament and of the Council of 19 November 2008 on waste and repealing certain Directives (OJ L 312, 22.11.2008, p. 3).] [Commission Regulation (EC) No 199/2006 of 3 February 2006 amending Regulation (EC) No 466/2001 setting maximum levels for certain contaminants in foodstuffs as regards dioxins and dioxin-like PCBs (OJ L 32, 4.2.2006, p. 34).]

Term used | Definition

General terms

Channelled emissions | Emissions of pollutants into the environment through any kind of duct, pipe, stack, etc. This also includes emissions from open-top biofilters.

Continuous measurement | Measurement using an ‘automated measuring system’ permanently installed on site.

Declaration of cleanliness | Written document provided by the waste producer/holder certifying that the empty waste packaging concerned (e.g. drums, containers) is clean with respect to the acceptance criteria.

Diffuse emissions | Non-channelled emissions (e.g. of dust, organic compounds, odour) which can result from ‘area’ sources (e.g. tanks) or ‘point’ sources (e.g. pipe flanges). This also includes emissions from open-air windrow composting.

Direct discharge | Discharge to a receiving water body without further downstream waste water treatment.

Emissions factors | Numbers that can be multiplied by known data such as plant/process data or throughput data to estimate emissions.

Existing plant | A plant that is not a new plant.

Flaring | High-temperature oxidation to burn combustible compounds of waste gases from industrial operations with an open flame. Flaring is primarily used for burning off flammable gas for safety reasons or during non-routine operating conditions.

Fly ashes | Particles from the combustion chamber or formed within the flue-gas stream, that are transported in the flue-gas.

Fugitive emissions | Diffuse emissions from ‘point’ sources.

Hazardous waste | Hazardous waste as defined in point 2 of Article 3 of Directive 2008/98/EC.

Indirect discharge | Discharge which is not a direct discharge.

Liquid biodegradable waste | Waste of biological origin with a relatively high water content (e.g. fat separator contents, organic sludges, catering waste).

Major plant upgrade | A major change in the design or technology of a plant with major adjustments or replacements of the process and/or abatement technique(s) and associated equipment.

Mechanical biological treatment (MBT) | Treatment of mixed solid waste combining mechanical treatment with biological treatment such as aerobic or anaerobic treatment.

New plant | A plant first permitted at the site of the installation following the publication of these BAT conclusions or a complete replacement of a plant following the publication of these BAT conclusions.

Output | The treated waste exiting the waste treatment plant.

Pasty waste | Sludge which is not free-flowing.

Periodic measurement | Measurement at specified time intervals using manual or automated methods.

Recovery | Recovery as defined in Article 3(15) of Directive 2008/98/EC.

Re-refining | Treatments carried out on waste oil to transform it to base oil.

Regeneration | Treatments and processes mainly designed to make the treated materials (e.g. spent activated carbon or spent solvent) suitable again for a similar use.

Sensitive receptor |

Area which needs special protection, such as:

residential areas;

areas where human activities are carried out (e.g. neighbouring workplaces, schools, daycare centres, recreational areas, hospitals or nursing homes).

Surface impoundment | Placement of liquid or sludgy discards into pits, ponds, lagoons, etc.

Treatment of waste with calorific value | Treatment of waste wood, waste oil, waste plastics, waste solvents, etc. to obtain a fuel or to allow a better recovery of its calorific value.

VFCs | Volatile (hydro)fluorocarbons: VOCs consisting of fluorinated (hydro)carbons, in particular chlorofluorocarbons (CFCs), hydrochlorofluorocarbons (HCFCs) and hydrofluorocarbons (HFCs).

VHCs | Volatile hydrocarbons: VOCs consisting entirely of hydrogen and carbon (e.g. ethane, propane, iso-butane, cyclopentane).

VOC | Volatile organic compound as defined in Article 3(45) of Directive 2010/75/EU.

Waste holder | Waste holder as defined in Article 3(6) of Directive 2008/98/EC of the European Parliament and of the Council.

Waste input | The incoming waste to be treated in the waste treatment plant.

Water-based liquid waste | Waste consisting of aqueous liquids, acids/alkalis or pumpable sludges (e.g. emulsions, waste acids, aqueous marine waste) which is not liquid biodegradable waste.

Pollutants/parameters

AOX | Adsorbable organically bound halogens, expressed as Cl, include adsorbable organically bound chlorine, bromine and iodine.

Arsenic | Arsenic, expressed as As, includes all inorganic and organic arsenic compounds, dissolved or bound to particles.

BOD | Biochemical oxygen demand. Amount of oxygen needed for the biochemical oxidation of organic and/or inorganic matter in five (BOD5) or in seven (BOD7) days.

Cadmium | Cadmium, expressed as Cd, includes all inorganic and organic cadmium compounds, dissolved or bound to particles.

CFCs | Chlorofluorocarbons: VOCs consisting of carbon, chlorine and fluorine.

Chromium | Chromium, expressed as Cr, includes all inorganic and organic chromium compounds, dissolved or bound to particles.

Hexavalent chromium | Hexavalent chromium, expressed as Cr(VI), includes all chromium compounds where the chromium is in the oxidation state +6.

COD | Chemical oxygen demand. Amount of oxygen needed for the total chemical oxidation of the organic matter to carbon dioxide. COD is an indicator for the mass concentration of organic compounds.

Copper | Copper, expressed as Cu, includes all inorganic and organic copper compounds, dissolved or bound to particles.

Cyanide | Free cyanide, expressed as CN-.

Dust | Total particulate matter (in air).

HOI | Hydrocarbon oil index. The sum of compounds extractable with a hydrocarbon solvent (including long-chain or branched aliphatic, alicyclic, aromatic or alkyl-substituted aromatic hydrocarbons).

HCl | All inorganic gaseous chlorine compounds, expressed as HCl.

HF | All inorganic gaseous fluorine compounds, expressed as HF.

H2S | Hydrogen sulphide. Carbonyl sulphide and mercaptans are not included.

Lead | Lead, expressed as Pb, includes all inorganic and organic lead compounds, dissolved or bound to particles.

Mercury | Mercury, expressed as Hg, includes elementary mercury and all inorganic and organic mercury compounds, gaseous, dissolved or bound to particles.

NH3 | Ammonia.

Nickel | Nickel, expressed as Ni, includes all inorganic and organic nickel compounds, dissolved or bound to particles.

Odour concentration | Number of European Odour Units (ouE) in one cubic metre at standard conditions measured by dynamic olfactometry according to EN 13725.

PCB | Polychlorinated biphenyl.

Dioxin-like PCBs | Polychlorinated biphenyls as listed in Commission Regulation (EC) No 199/2006.

PCDD/F | Polychlorinated dibenzo-p-dioxin/furan(s).

PFOA | Perfluorooctanoic acid.

PFOS | Perfluorooctanesulphonic acid.

Phenol index | The sum of phenolic compounds, expressed as phenol concentration and measured according to EN ISO 14402.

TOC | Total organic carbon, expressed as C (in water), includes all organic compounds.

Total N | Total nitrogen, expressed as N, includes free ammonia and ammonium nitrogen (NH4-N), nitrite nitrogen (NO2-N), nitrate nitrogen (NO3-N) and organically bound nitrogen.

Total P | Total phosphorus, expressed as P, includes all inorganic and organic phosphorus compounds, dissolved or bound to particles

TSS | Total suspended solids. Mass concentration of all suspended solids (in water), measured via filtration through glass fibre filters and gravimetry.

TVOC | Total volatile organic carbon, expressed as C (in air).

Zinc | Zinc, expressed as Zn, includes all inorganic and organic zinc compounds, dissolved or bound to particles.

For the purposes of these BAT conclusions, the following acronyms apply:

[Directive 2000/53/EC of the European Parliament and of the Council of 18 September 2000 on end-of life vehicles (OJ L 269, 21.10.2000, p. 34).] [Regulation (EC) No 850/2004 of the European Parliament and of the Council of 29 April 2004 on persistent organic pollutants and amending Directive 79/117/EEC (OJ L 158, 30.4.2004, p. 7).] [Directive 2012/19/EU of the European Parliament and of the Council of 4 July 2012 on waste electrical and electronic equipment (WEEE) (OJ L 197, 24.7.2012, p. 38).]

Acronym | Definition

EMS | Environmental management system

EoLVs | End-of-life vehicles (as defined in Article 2(2) of Directive 2000/53/EC of the European Parliament and of the Council)

HEPA | High-efficiency particle air (filter)

IBC | Intermediate bulk container

LDAR | Leak detection and repair

LEV | Local exhaust ventilation system

POP | Persistent organic pollutant (as listed in Regulation (EC) No 850/2004 of the European Parliament and of the Council)

WEEE | Waste electrical and electronic equipment (as defined in Article 3(1) of Directive 2012/19/EU of the European Parliament and of the Council)

The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection.

Unless otherwise stated, the BAT conclusions are generally applicable.

Unless stated otherwise, emission levels associated with the best available techniques (BAT-AELs) for emissions to air given in these BAT conclusions refer to concentrations (mass of emitted substances per volume of waste gas) under the following standard conditions: dry gas at a temperature of 273,15 K and a pressure of 101,3 kPa, without correction for oxygen content, and expressed in μg/Nm3 or mg/Nm3.

For averaging periods of BAT-AELs for emissions to air, the following definitions apply.

[For any parameter where, due to sampling or analytical limitations, a 30-minute measurement is inappropriate, a more suitable measurement period may be employed (e.g. for the odour concentration). For PCDD/F or dioxin-like PCBs, one sampling period of 6 to 8 hours is used.]

Type of measurement | Averaging period | Definition

Continuous | Daily average | Average over a period of one day based on valid hourly or half-hourly averages.

Periodic | Average over the sampling period | Average value of three consecutive measurements of at least 30 minutes each.

Where continuous measurement is used, the BAT-AELs may be expressed as daily averages.

Unless stated otherwise, emission levels associated with the best available techniques (BAT-AELs) for emissions to water given in these BAT conclusions refer to concentrations (mass of emitted substances per volume of water), expressed in μg/l or mg/l.

Unless stated otherwise, averaging periods associated with the BAT-AELs refer to either of the following two cases:

in the case of continuous discharge, daily average values, i.e. 24-hour flow-proportional composite samples;

in the case of batch discharge, average values over the release duration taken as flow-proportional composite samples, or, provided that the effluent is appropriately mixed and homogeneous, a spot sample taken before discharge.

Time-proportional composite samples can be used provided that sufficient flow stability is demonstrated.

All BAT-AELs for emissions to water apply at the point where the emission leaves the installation.

The calculation of the average abatement efficiency referred to in these BAT conclusions (see Table 6.1) does not include, for COD and TOC, initial treatment steps aiming at separating the bulk organic content from the water-based liquid waste, such as evapo-condensation, emulsion breaking or phase separation.

BAT 1. In order to improve the overall environmental performance, BAT is to implement and adhere to an environmental management system (EMS) that incorporates all of the following features:

I.

commitment of the management, including senior management;

II.

definition, by the management, of an environmental policy that includes the continuous improvement of the environmental performance of the installation;

III.

planning and establishing the necessary procedures, objectives and targets, in conjunction with financial planning and investment;

IV.

implementation of procedures paying particular attention to:

(a)

structure and responsibility,

(b)

recruitment, training, awareness and competence,

(c)

communication,

(d)

employee involvement,

(e)

documentation,

(f)

effective process control,

(g)

maintenance programmes,

(h)

emergency preparedness and response,

(i)

safeguarding compliance with environmental legislation;

V.

checking performance and taking corrective action, paying particular attention to:

(a)

monitoring and measurement (see also the JRC Reference Report on Monitoring of emissions to air and water from IED installations – ROM),

(b)

corrective and preventive action,

(c)

maintenance of records,

(d)

independent (where practicable) internal or external auditing in order to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained;

VI.

review, by senior management, of the EMS and its continuing suitability, adequacy and effectiveness;

VII.

following the development of cleaner technologies;

VIII.

consideration for the environmental impacts from the eventual decommissioning of the plant at the stage of designing a new plant, and throughout its operating life;

IX.

application of sectoral benchmarking on a regular basis;

X.

waste stream management (see BAT 2);

XI.

an inventory of waste water and waste gas streams (see BAT 3);

XII.

residues management plan (see description in Section 6.5);

XIII.

accident management plan (see description in Section 6.5);

XIV.

odour management plan (see BAT 12);

XV.

noise and vibration management plan (see BAT 17).

The scope (e.g. level of detail) and nature of the EMS (e.g. standardised or non-standardised) will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have (determined also by the type and amount of wastes processed).

BAT 2. In order to improve the overall environmental performance of the plant, BAT is to use all of the techniques given below.

[Sorting techniques are described in Section 6.4]

Technique | Description

a.

| Set up and implement waste characterisation and pre-acceptance procedures | These procedures aim to ensure the technical (and legal) suitability of waste treatment operations for a particular waste prior to the arrival of the waste at the plant. They include procedures to collect information about the waste input and may include waste sampling and characterisation to achieve sufficient knowledge of the waste composition. Waste pre-acceptance procedures are risk-based considering, for example, the hazardous properties of the waste, the risks posed by the waste in terms of process safety, occupational safety and environmental impact, as well as the information provided by the previous waste holder(s).

b.

| Set up and implement waste acceptance procedures | Acceptance procedures aim to confirm the characteristics of the waste, as identified in the pre-acceptance stage. These procedures define the elements to be verified upon the arrival of the waste at the plant as well as the waste acceptance and rejection criteria. They may include waste sampling, inspection and analysis. Waste acceptance procedures are risk-based considering, for example, the hazardous properties of the waste, the risks posed by the waste in terms of process safety, occupational safety and environmental impact, as well as the information provided by the previous waste holder(s).