These BAT conclusions concern the production of the following organic chemicals, as specified in Section 4.1 of Annex I to Directive 2010/75/EU:
simple hydrocarbons (linear or cyclic, saturated or unsaturated, aliphatic or aromatic);
oxygen-containing hydrocarbons such as alcohols, aldehydes, ketones, carboxylic acids, esters and mixtures of esters, acetates, ethers, peroxides and epoxy resins;
sulphurous hydrocarbons;
nitrogenous hydrocarbons such as amines, amides, nitrous compounds, nitro compounds or nitrate compounds, nitriles, cyanates, isocyanates;
phosphorus-containing hydrocarbons;
halogenic hydrocarbons;
organometallic compounds;
surface-active agents and surfactants.
These BAT conclusions also cover the production of hydrogen peroxide as specified in Section 4.2(e) of Annex I to Directive 2010/75/EU.
These BAT conclusions cover combustion of fuels in process furnaces/heaters, where this is part of the abovementioned activities.
These BAT conclusions cover production of the aforementioned chemicals in continuous processes where the total production capacity of those chemicals exceeds 20 kt/year.
These BAT conclusions do not address the following:
combustion of fuels other than in a process furnace/heater or a thermal/catalytic oxidiser; this may be covered by the BAT conclusions for Large Combustion Plants (LCP);
incineration of waste; this may be covered by the BAT conclusions for Waste Incineration (WI);
ethanol production taking place on an installation covered by the activity description in Section 6.4(b)(ii) of Annex I to Directive 2010/75/EU or covered as a directly associated activity to such an installation; this may be covered by the BAT conclusions for Food, Drink and Milk Industries (FDM).
Other BAT conclusions which are complementary for the activities covered by these BAT conclusions include:
Common Waste Water/Waste Gas Treatment/Management Systems in the Chemical Sector (CWW);
Common Waste Gas Treatment in the Chemical Sector (WGC).
Other BAT conclusions and reference documents which may be of relevance for the activities covered by these BAT conclusions are the following:
Economics and Cross-media Effects (ECM);
Emissions from Storage (EFS);
Energy Efficiency (ENE);
Industrial Cooling Systems (ICS);
Large Combustion Plants (LCP);
Refining of Mineral Oil and Gas (REF);
Monitoring of Emissions to Air and Water from IED installations (ROM);
Waste Incineration (WI);
Waste Treatment (WT).
The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection.
Unless otherwise stated, the BAT conclusions are generally applicable.
Unless stated otherwise, the emission levels associated with the best available techniques (BAT-AELs) for emissions to air given in these BAT conclusions refer to values of concentration, expressed as mass of emitted substance per volume of waste gas under standard conditions (dry gas at a temperature of 273,15 K, and a pressure of 101,3 kPa), and expressed in the unit mg/Nm3.
Unless stated otherwise, the averaging periods associated with the BAT-AELs for emissions to air are defined as follows.
[For any parameter where, due to sampling or analytical limitations, 30-minute sampling is inappropriate, a suitable sampling period is employed.] [For PCDD/F, a sampling period of 6 to 8 hours is used.]
Type of measurement | Averaging period | Definition
Continuous | Daily average | Average over a period of 1 day based on valid hourly or half-hourly averages
Periodic | Average over the sampling period | Average of three consecutive measurements of at least 30 minutes each
Where BAT-AELs refer to specific emission loads, expressed as load of emitted substance per unit of production output, the average specific emission loads ls are calculated using Equation 1:
Equation 1: | ls1
n
ni1
ciqi
pi
where:
nnumber of measurement periods;
ciaverage concentration of the substance during ith measurement period;
qiaverage flow rate during ith measurement period;
piproduction output during ith measurement period.
For process furnaces/heaters, the reference oxygen level of the waste gases (OR) is 3 vol-%.
The emission concentration at the reference oxygen level is calculated using Equation 2:
Equation 2: | ER21OR21OM EM
where:
ERemission concentration at the reference oxygen level OR;
ORreference oxygen level in vol-%;
EMmeasured emission concentration;
OMmeasured oxygen level in vol-%.
Unless stated otherwise, the averaging periods associated with the environmental performance levels associated with the best available techniques (BAT-AEPLs) for emissions to water expressed in concentrations are defined as follows.
[Time-proportional composite samples can be used provided that sufficient flow stability can be demonstrated.]
Averaging period | Definition
Average of values obtained during one month | Flow-weighted average value from 24-hour flow-proportional composite samples obtained during 1 month under normal operating conditions
Average of values obtained during one year | Flow-weighted average value from 24-hour flow-proportional composite samples obtained during 1 year under normal operating conditions
Flow-weighted average concentrations of the parameter (cw) are calculated using Equation 3:
Equation 3: | cw
ni1
ciqi
ni1
qi
where:
nnumber of measurement periods;
ciaverage concentration of the parameter during ith measurement period;
qiaverage flow rate during ith measurement period.
Where BAT-AEPLs refer to specific emission loads, expressed as load of emitted substance per unit of production output, the average specific emission loads are calculated using Equation 1.
For the purposes of these BAT conclusions, the following acronyms and definitions apply.
[Commission Implementing Decision 2012/119/EU of 10 February 2012 laying down rules concerning guidance on the collection of data and on the drawing up of BAT reference documents and on their quality assurance referred to in Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions (OJ L 63, 2.3.2012, p. 1).]
Term used | Definition
BAT-AEPL | Environmental performance level associated with BAT, as described in Commission Implementing Decision 2012/119/EU. BAT-AEPLs include emission levels associated with the best available techniques (BAT-AELs) as defined in Article 3(13) of Directive 2010/75/EU
BTX | Collective term for benzene, toluene and ortho-/meta-/para-xylene or mixtures thereof
CO | Carbon monoxide
Combustion unit | Any technical apparatus in which fuels are oxidised in order to use the heat thus generated. Combustion units include boilers, engines, turbines and process furnaces/heaters, but do not include waste gas treatment units (e.g. a thermal/catalytic oxidiser used for the abatement of organic compounds)
Continuous measurement | Measurement using an ‘automated measuring system’ permanently installed on site
Continuous process | A process in which the raw materials are fed continuously into the reactor with the reaction products then fed into connected downstream separation and/or recovery units
Copper | The sum of copper and its compounds, in dissolved or particulate form, expressed as Cu
DNT | Dinitrotoluene
EB | Ethylbenzene
EDC | Ethylene dichloride
EG | Ethylene glycols
EO | Ethylene oxide
Ethanolamines | Collective term for monoethanolamine, diethanolamine and triethanolamine, or mixtures thereof
Ethylene glycols | Collective term for monoethylene glycol, diethylene glycol and triethylene glycol, or mixtures thereof
Existing plant | A plant that is not a new plant
Existing unit | A unit that is not a new unit
Flue-gas | The exhaust gas exiting a combustion unit
I-TEQ | International toxic equivalent – derived by using the international toxic equivalence factors, as defined in Annex VI, part 2 to Directive 2010/75/EU
Lower olefins | Collective term for ethylene, propylene, butylene and butadiene, or mixtures thereof
Major plant upgrade | A major change in the design or technology of a plant with major adjustments or replacements of the process and/or abatement units and associated equipment
MDA | Methylene diphenyl diamine
MDI | Methylene diphenyl diisocyanate
MDI plant | Plant for the production of MDI from MDA via phosgenation
New plant | A plant first permitted on the site of the installation following the publication of these BAT conclusions or a complete replacement of a plant following the publication of these BAT conclusions
New unit | A unit first permitted following the publication of these BAT conclusions or a complete replacement of a unit following the publication of these BAT conclusions
NOX precursors | Nitrogen-containing compounds (e.g. ammonia, nitrous gases and nitrogen-containing organic compounds) in the input to a thermal treatment that lead to NOX emissions. Elementary nitrogen is not included
PCDD/F | Polychlorinated dibenzo-dioxins and -furans
Periodic measurement | Measurement at specified time intervals using manual or automated methods
Process furnace/heater |
Process furnaces or heaters are:
combustion units whose flue-gases are used for the thermal treatment of objects or feed material through direct contact, e.g. in drying processes or chemical reactors; or
combustion units whose radiant and/or conductive heat is transferred to objects or feed material through a solid wall without using an intermediary heat transfer fluid, e.g. furnaces or reactors heating a process stream used in the (petro-)chemical industry such as steam cracker furnaces.
It should be noted that, as a consequence of the application of good energy recovery practices, some of the process furnaces/heaters may have an associated steam/electricity generation system. This is considered to be an integral design feature of the process furnace/heater that cannot be considered in isolation.
Process off-gas | The gas leaving a process which is further treated for recovery and/or abatement
NOX | The sum of nitrogen monoxide (NO) and nitrogen dioxide (NO2), expressed as NO2
Residues | Substances or objects generated by the activities covered by the scope of this document, as waste or by-products
RTO | Regenerative thermal oxidiser
SCR | Selective catalytic reduction
SMPO | Styrene monomer and propylene oxide
SNCR | Selective non-catalytic reduction
SRU | Sulphur recovery unit
TDA | Toluene diamine
TDI | Toluene diisocyanate
TDI plant | Plant for the production of TDI from TDA via phosgenation
TOC | Total organic carbon, expressed as C; includes all organic compounds (in water)
Total suspended solids (TSS) | Mass concentration of all suspended solids, measured via filtration through glass fibre filters and gravimetry
TVOC | Total volatile organic carbon; total volatile organic compounds which are measured by a flame ionisation detector (FID) and expressed as total carbon
Unit | A segment/subpart of a plant in which a specific process or operation is carried out (e.g. reactor, scrubber, distillation column). Units can be new units or existing units
Valid hourly or half-hourly average | An hourly (or half-hourly) average is considered valid when there is no maintenance or malfunction of the automated measuring system
VCM | Vinyl chloride monomer
VOCs | Volatile organic compounds as defined in Article 3(45) of Directive 2010/75/EU
The sector-specific BAT conclusions included in Sections 2 to 11 apply in addition to the general BAT conclusions given in this section.
BAT 1: BAT is to monitor channelled emissions to air from process furnaces/heaters in accordance with EN standards and with at least the minimum frequency given in the table below. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.
[Generic EN standards for continuous measurements are EN 15267-1, -2, and -3, and EN 14181. EN standards for periodic measurements are given in the table.] [Refers to the total rated thermal input of all process furnaces/heaters connected to the stack where emissions occur.] [In the case of process furnaces/heaters with a total rated thermal input of less than 100 MWth operated less than 500 hours per year, the monitoring frequency may be reduced to at least once every year.] [The minimum monitoring frequency for periodic measurements may be reduced to once every 6 months, if the emission levels are proven to be sufficiently stable.] [Monitoring of dust does not apply when combusting exclusively gaseous fuels.] [Monitoring of NH3 only applies when SCR or SNCR is used.] [In the case of process furnaces/heaters combusting gaseous fuels and/or oil with a known sulphur content and where no flue-gas desulphurisation is carried out, continuous monitoring can be replaced either by periodic monitoring with a minimum frequency of once every 3 months or by calculation ensuring the provision of data of an equivalent scientific quality.]
Substance/Parameter | Standard(s) | Total rated thermal input (MWth) | Minimum monitoring frequency | Monitoring associated with
CO | Generic EN standards | ≥ 50 | Continuous |
Table 2.1,
Table 10.1
EN 15058 | 10 to < 50 | Once every 3 months
Dust | Generic EN standards and EN 13284-2 | ≥ 50 | Continuous | BAT 5
EN 13284-1 | 10 to < 50 | Once every 3 months
NH3 | Generic EN standards | ≥ 50 | Continuous |
BAT 7,
Table 2.1
No EN standard available | 10 to < 50 | Once every 3 months
NOX | Generic EN standards | ≥ 50 | Continuous |
BAT 4,
Table 2.1,
Table 10.1
EN 14792 | 10 to < 50 | Once every 3 months
SO2 | Generic EN standards | ≥ 50 | Continuous | BAT 6
EN 14791 | 10 to < 50 | Once every 3 months
BAT 2: BAT is to monitor channelled emissions to air other than from process furnaces/heaters in accordance with EN standards and with at least the minimum frequency given in the table below. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.
[The monitoring applies where the pollutant is present in the waste gas based on the inventory of waste gas streams specified by the CWW BAT conclusions.] [The minimum monitoring frequency for periodic measurements may be reduced to once every year, if the emission levels are proven to be sufficiently stable.] [All (other) processes/sources where the pollutant is present in the waste gas based on the inventory of waste gas streams specified by the CWW BAT conclusions.] [EN 15058 and the sampling period need adaptation so that the measured values are representative of the whole decoking cycle.] [EN 13284-1 and the sampling period need adaptation so that the measured values are representative of the whole decoking cycle.] [The monitoring applies where the chlorine and/or chlorinated compounds are present in the waste gas and thermal treatment is applied]
Substance/Parameter | Processes/Sources | Standard(s) | Minimum monitoring frequency | Monitoring associated with
Benzene | Waste gas from the cumene oxidation unit in phenol production | No EN standard available | Once every month | BAT 57
All other processes/sources | BAT 10
Cl2 | TDI/MDI | No EN standard available | Once every month | BAT 66
EDC/VCM | BAT 76
CO | Thermal oxidiser | EN 15058 | Once every month | BAT 13
Lower olefins (decoking) | No EN standard available | Once every year or once during decoking, if decoking is less frequent | BAT 20
EDC/VCM (decoking) | BAT 78
Dust | Lower olefins (decoking) | No EN standard available | Once every year or once during decoking, if decoking is less frequent | BAT 20
EDC/VCM (decoking) | BAT 78
All other processes/sources | EN 13284-1 | Once every month | BAT 11
EDC | EDC/VCM | No EN standard available | Once every month | BAT 76
Ethylene oxide | Ethylene oxide and ethylene glycols | No EN standard available | Once every month | BAT 52
Formaldehyde | Formaldehyde | No EN standard available | Once every month | BAT 45
Gaseous chlorides, expressed as HCl | TDI/MDI | EN 1911 | Once every month | BAT 66
EDC/VCM | BAT 76
All other processes/sources | BAT 12
NH3 | Use of SCR or SNCR | No EN standard available | Once every month | BAT 7
NOX | Thermal oxidiser | EN 14792 | Once every month | BAT 13
PCDD/F | TDI/MDI | EN 1948-1, -2, and -3 | Once every 6 months | BAT 67
PCDD/F | EDC/VCM | BAT 77
SO2 | All processes/sources | EN 14791 | Once every month | BAT 12
Tetrachloromethane | TDI/MDI | No EN standard available | Once every month | BAT 66
TVOC | TDI/MDI | EN 12619 | Once every month | BAT 66
EO (desorption of CO2 from scrubbing medium) | Once every 6 months | BAT 51
Formaldehyde | Once every month | BAT 45
Waste gas from the cumene oxidation unit in phenol production | EN 12619 | Once every month | BAT 57
Waste gas from other sources in phenol production when not combined with other waste gas streams | Once every year
Waste gas from the oxidation unit in hydrogen peroxide production | Once every month | BAT 86
EDC/VCM | Once every month | BAT 76
All other processes/sources | Once every month | BAT 10
VCM | EDC/VCM | No EN standard available | Once every month | BAT 76
BAT 3: In order to reduce emissions to air of CO and unburnt substances from process furnaces/heaters, BAT is to ensure an optimised combustion.
Optimised combustion is achieved by good design and operation of the equipment which includes optimisation of the temperature and residence time in the combustion zone, efficient mixing of the fuel and combustion air, and combustion control. Combustion control is based on the continuous monitoring and automated control of appropriate combustion parameters (e.g. O2, CO, fuel to air ratio, and unburnt substances).
BAT 4: In order to reduce NOX emissions to air from process furnaces/heaters, BAT is to use one or a combination of the techniques given below.
Technique | Description | Applicability
| Choice of fuel | See Section 12.3. This includes switching from liquid to gaseous fuels, taking into account the overall hydrocarbon balance | The switch from liquid to gaseous fuels may be restricted by the design of the burners in the case of existing plants
| Staged combustion | Staged combustion burners achieve lower NOX emissions by staging the injection of either air or fuel in the near burner region. The division of fuel or air reduces the oxygen concentration in the primary burner combustion zone, thereby lowering the peak flame temperature and reducing thermal NOX formation |
Applicability may be restricted by space availability when upgrading small process furnaces, thus limiting the retrofit of fuel/air staging without reducing capacity
For existing EDC crackers, the applicability may be restricted by the design of the process furnace
| Flue-gas recirculation (external) | Recirculation of part of the flue-gas to the combustion chamber to replace part of the fresh combustion air, with the effect of reducing the oxygen content and therefore cooling the temperature of the flame |
For existing process furnaces/heaters, the applicability may be restricted by their design.
Not applicable to existing EDC crackers
| Flue-gas recirculation (internal) | Recirculation of part of the flue-gas within the combustion chamber to replace part of the fresh combustion air, with the effect of reducing the oxygen content and therefore reducing the temperature of the flame | For existing process furnaces/heaters, the applicability may be restricted by their design
| Low-NOX burner (LNB) or ultra-low-NOX burner (ULNB) | See Section 12.3 | For existing process furnaces/heaters, the applicability may be restricted by their design
| Use of inert diluents | ‘Inert’ diluents, e.g. steam, water, nitrogen, are used (either by being premixed with the fuel prior to its combustion or directly injected into the combustion chamber) to reduce the temperature of the flame. Steam injection may increase CO emissions | Generally applicable
| Selective catalytic reduction (SCR) | See Section 12.1 | Applicability to existing process furnaces/heaters may be restricted by space availability
| Selective non-catalytic reduction (SNCR) | See Section 12.1 |
Applicability to existing process furnaces/heaters may be restricted by the temperature window (900–1050 °C) and the residence time needed for the reaction.
Not applicable to EDC crackers
BAT-associated emission levels (BAT-AELs): See Table 2.1 and Table 10.1.
BAT 5: In order to prevent or reduce dust emissions to air from process furnaces/heaters, BAT is to use one or a combination of the techniques given below.
Technique | Description | Applicability
| Choice of fuel | See Section 12.3. This includes switching from liquid to gaseous fuels, taking into account the overall hydrocarbon balance | The switch from liquid to gaseous fuels may be restricted by the design of the burners in the case of existing plants
| Atomisation of liquid fuels | Use of high pressure to reduce the droplet size of liquid fuel. Current optimal burner design generally includes steam atomisation | Generally applicable
| Fabric, ceramic or metal filter | See Section 12.1 | Not applicable when only combusting gaseous fuels
BAT 6: In order to prevent or reduce SO2 emissions to air from process furnaces/heaters, BAT is to use one or both of the techniques given below.
Technique | Description | Applicability
| Choice of fuel | See Section 12.3. This includes switching from liquid to gaseous fuels, taking into account the overall hydrocarbon balance | The switch from liquid to gaseous fuels may be restricted by the design of the burners in the case of existing plants
| Caustic scrubbing | See Section 12.1 | Applicability may be restricted by space availability
BAT 7: In order to reduce emissions to air of ammonia which is used in selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) for the abatement of NOX emissions, BAT is to optimise the design and/or operation of SCR or SNCR (e.g. optimised reagent to NOX ratio, homogeneous reagent distribution and optimum size of the reagent drops).
BAT-associated emission levels (BAT-AELs) for emissions from a lower olefins cracker furnace when SCR or SNCR is used: Table 2.1.
BAT 8: In order to reduce the load of pollutants sent to the final waste gas treatment, and to increase resource efficiency, BAT is to use an appropriate combination of the techniques given below for process off-gas streams.
Technique | Description | Applicability