1 ANNEX, Decision_act (EU) 2017/1442

In forcesince 31 Jul 2017

These BAT conclusions concern the following activities specified in Annex I to Directive 2010/75/EU:

1.1: Combustion of fuels in installations with a total rated thermal input of 50 MW or more, only when this activity takes place in combustion plants with a total rated thermal input of 50 MW or more.

1.4: Gasification of coal or other fuels in installations with a total rated thermal input of 20 MW or more, only when this activity is directly associated to a combustion plant.

5.2: Disposal or recovery of waste in waste co-incineration plants for non-hazardous waste with a capacity exceeding 3 tonnes per hour or for hazardous waste with a capacity exceeding 10 tonnes per day, only when this activity takes place in combustion plants covered under 1.1 above.

In particular, these BAT conclusions cover upstream and downstream activities directly associated with the aforementioned activities including the emission prevention and control techniques applied.

The fuels considered in these BAT conclusions are any solid, liquid and/or gaseous combustible material including:

solid fuels (e.g. coal, lignite, peat),

biomass (as defined in Article 3(31) of Directive 2010/75/EU),

liquid fuels (e.g. heavy fuel oil and gas oil),

gaseous fuels (e.g. natural gas, hydrogen-containing gas and syngas),

industry-specific fuels (e.g. by-products from the chemical and iron and steel industries),

waste except mixed municipal waste as defined in Article 3(39) and except other waste listed in Article 42(2)(a)(ii) and (iii) of Directive 2010/75/EU.

These BAT conclusions do not address the following:

combustion of fuels in units with a rated thermal input of less than 15 MW,

combustion plants benefitting from the limited life time or district heating derogation as set out in Articles 33 and 35 of Directive 2010/75/EU, until the derogations set in their permits expire, for what concerns the BAT-AELs for the pollutants covered by the derogation, as well as for other pollutants whose emissions would have been reduced by the technical measures obviated by the derogation,

gasification of fuels, when not directly associated to the combustion of the resulting syngas,

gasification of fuels and subsequent combustion of syngas when directly associated to the refining of mineral oil and gas,

the upstream and downstream activities not directly associated to combustion or gasification activities,

combustion in process furnaces or heaters,

combustion in post-combustion plants,

flaring,

combustion in recovery boilers and total reduced sulphur burners within installations for the production of pulp and paper, as this is covered by the BAT conclusions for the production of pulp, paper and board,

combustion of refinery fuels at the refinery site, as this is covered by the BAT conclusions for the refining of mineral oil and gas,

disposal or recovery of waste in:

waste incineration plants (as defined in Article 3(40) of Directive 2010/75/EU),

waste co-incineration plants where more than 40 % of the resulting heat release comes from hazardous waste,

waste co-incineration plants combusting only wastes, except if these wastes are composed at least partially of biomass as defined in Article 3(31)(b) of Directive 2010/75/EU,

as this is covered by the BAT conclusions for waste incineration.

Other BAT conclusions and reference documents that could be relevant for the activities covered by these BAT conclusions are the following:

Common Waste Water and Waste Gas Treatment/Management Systems in the Chemical Sector (CWW)

Chemical BREF series (LVOC, etc.)

Economics and Cross-Media Effects (ECM)

Emissions from Storage (EFS)

Energy Efficiency (ENE)

Industrial Cooling Systems (ICS)

Iron and Steel Production (IS)

Monitoring of Emissions to Air and Water from IED installations (ROM)

Production of Pulp, Paper and Board (PP)

Refining of Mineral Oil and Gas (REF)

Waste Incineration (WI)

Waste Treatment (WT)

For the purposes of these BAT conclusions, the following definitions apply:

[Commission Implementing Decision 2012/249/EU of 7 May 2012 concerning the determination of start-up and shut-down periods for the purposes of Directive 2010/75/EU of the European Parliament and of the Council on industrial emissions (OJ L 123, 9.5.2012, p. 44).]

Term used | Definition

General terms

Boiler | Any combustion plant with the exception of engines, gas turbines, and process furnaces or heaters

Combined-cycle gas turbine (CCGT) |

A CCGT is a combustion plant where two thermodynamic cycles are used (i.e. Brayton and Rankine cycles). In a CCGT, heat from the flue-gas of a gas turbine (operating according to the Brayton cycle to produce electricity) is converted to useful energy in a heat recovery steam generator (HRSG), where it is used to generate steam, which then expands in a steam turbine (operating according to the Rankine cycle to produce additional electricity).

For the purpose of these BAT conclusions, a CCGT includes configurations both with and without supplementary firing of the HRSG

Combustion plant |

Any technical apparatus in which fuels are oxidised in order to use the heat thus generated. For the purposes of these BAT conclusions, a combination formed of:

two or more separate combustion plants where the flue-gases are discharged through a common stack, or

separate combustion plants that have been granted a permit for the first time on or after 1 July 1987, or for which the operators have submitted a complete application for a permit on or after that date, which are installed in such a way that, taking technical and economic factors into account, their flue-gases could, in the judgment of the competent authority, be discharged through a common stack

is considered as a single combustion plant.

For calculating the total rated thermal input of such a combination, the capacities of all individual combustion plants concerned, which have a rated thermal input of at least 15 MW, shall be added together

Combustion unit | Individual combustion plant

Continuous measurement | Measurement using an automated measuring system permanently installed on site

Direct discharge | Discharge (to a receiving water body) at the point where the emission leaves the installation without further downstream treatment

Flue-gas desulphurisation (FGD) system | System composed of one or a combination of abatement technique(s) whose purpose is to reduce the level of SOX emitted by a combustion plant

Flue-gas desulphurisation (FGD) system — existing | A flue-gas desulphurisation (FGD) system that is not a new FGD system

Flue-gas desulphurisation (FGD) system — new | Either a flue-gas desulphurisation (FGD) system in a new plant or a FGD system that includes at least one abatement technique introduced or completely replaced in an existing plant following the publication of these BAT conclusions

Gas oil |

Any petroleum-derived liquid fuel falling within CN code 27101925, 27101929, 27101947, 27101948, 27102017 or 27102019.

Or any petroleum-derived liquid fuel of which less than 65 vol-% (including losses) distils at 250 °C and of which at least 85 vol-% (including losses) distils at 350 °C by the ASTM D86 method

Heavy fuel oil (HFO) |

Any petroleum-derived liquid fuel falling within CN code 27101951 to 27101968, 27102031, 27102035, 27102039.

Or any petroleum-derived liquid fuel, other than gas oil, which, by reason of its distillation limits, falls within the category of heavy oils intended for use as fuel and of which less than 65 vol-% (including losses) distils at 250 °C by the ASTM D86 method. If the distillation cannot be determined by the ASTM D86 method, the petroleum product is also categorised as a heavy fuel oil

Net electrical efficiency (combustion unit and IGCC) | Ratio between the net electrical output (electricity produced on the high-voltage side of the main transformer minus the imported energy — e.g. for auxiliary systems' consumption) and the fuel/feedstock energy input (as the fuel/feedstock lower heating value) at the combustion unit boundary over a given period of time

Net mechanical energy efficiency | Ratio between the mechanical power at load coupling and the thermal power supplied by the fuel

Net total fuel utilisation (combustion unit and IGCC) | Ratio between the net produced energy (electricity, hot water, steam, mechanical energy produced minus the imported electrical and/or thermal energy (e.g. for auxiliary systems' consumption)) and the fuel energy input (as the fuel lower heating value) at the combustion unit boundary over a given period of time

Net total fuel utilisation (gasification unit) | Ratio between the net produced energy (electricity, hot water, steam, mechanical energy produced, and syngas (as the syngas lower heating value) minus the imported electrical and/or thermal energy (e.g. for auxiliary systems' consumption)) and the fuel/feedstock energy input (as the fuel/feedstock lower heating value) at the gasification unit boundary over a given period of time

Operated hours | The time, expressed in hours, during which a combustion plant, in whole or in part, is operated and is discharging emissions to air, excluding start-up and shutdown periods

Periodic measurement | Determination of a measurand (a particular quantity subject to measurement) at specified time intervals

Plant — existing | A combustion plant that is not a new plant

Plant — new | A combustion plant first permitted at the installation following the publication of these BAT conclusions or a complete replacement of a combustion plant on the existing foundations following the publication of these BAT conclusions

Post-combustion plant | System designed to purify the flue-gases by combustion which is not operated as an independent combustion plant, such as a thermal oxidiser (i.e. tail gas incinerator), used for the removal of the pollutant(s) (e.g. VOC) content from the flue-gas with or without the recovery of the heat generated therein. Staged combustion techniques, where each combustion stage is confined within a separate chamber, which may have distinct combustion process characteristics (e.g. fuel to air ratio, temperature profile), are considered integrated in the combustion process and are not considered post-combustion plants. Similarly, when gases generated in a process heater/furnace or in another combustion process are subsequently oxidised in a distinct combustion plant to recover their energetic value (with or without the use of auxiliary fuel) to produce electricity, steam, hot water/oil or mechanical energy, the latter plant is not considered a post-combustion plant

Predictive emissions monitoring system (PEMS) | System used to determine the emissions concentration of a pollutant from an emission source on a continuous basis, based on its relationship with a number of characteristic continuously monitored process parameters (e.g. the fuel gas consumption, the air to fuel ratio) and fuel or feed quality data (e.g. the sulphur content)

Process fuels from the chemical industry | Gaseous and/or liquid by-products generated by the (petro-)chemical industry and used as non-commercial fuels in combustion plants

Process furnaces or heaters |

Process furnaces or heaters are:

combustion plants whose flue-gases are used for the thermal treatment of objects or feed material through a direct contact heating mechanism (e.g. cement and lime kiln, glass furnace, asphalt kiln, drying process, reactor used in the (petro-)chemical industry, ferrous metal processing furnaces), or

combustion plants whose radiant and/or conductive heat is transferred to objects or feed material through a solid wall without using an intermediary heat transfer fluid (e.g. coke battery furnace, cowper, furnace or reactor heating a process stream used in the (petro-)chemical industry such as a steam cracker furnace, process heater used for the regasification of liquefied natural gas (LNG) in LNG terminals).

As a consequence of the application of good energy recovery practices, process heaters/furnaces may have an associated steam/electricity generation system. This is considered to be an integral design feature of the process heater/furnace that cannot be considered in isolation

Refinery fuels | Solid, liquid or gaseous combustible material from the distillation and conversion steps of the refining of crude oil. Examples are refinery fuel gas (RFG), syngas, refinery oils, and pet coke

Residues | Substances or objects generated by the activities covered by the scope of this document, as waste or by-products

Start-up and shut-down period | The time period of plant operation as determined pursuant to the provisions of Commission Implementing Decision 2012/249/EU

Unit — existing | A combustion unit that is not a new unit

Unit- new | A combustion unit first permitted at the combustion plant following the publication of these BAT conclusions or a complete replacement of a combustion unit on the existing foundations of the combustion plant following the publication of these BAT conclusions

Valid (hourly average) | An hourly average is considered valid when there is no maintenance or malfunction of the automated measuring system

Term used | Definition

Pollutants/parameters

As | The sum of arsenic and its compounds, expressed as As

C3 | Hydrocarbons having a carbon number equal to three

C4+ | Hydrocarbons having a carbon number of four or greater

Cd | The sum of cadmium and its compounds, expressed as Cd

Cd+Tl | The sum of cadmium, thallium and their compounds, expressed as Cd+Tl

CH4 | Methane

CO | Carbon monoxide

COD | Chemical oxygen demand. Amount of oxygen needed for the total oxidation of the organic matter to carbon dioxide

COS | Carbonyl sulphide

Cr | The sum of chromium and its compounds, expressed as Cr

Cu | The sum of copper and its compounds, expressed as Cu

Dust | Total particulate matter (in air)

Fluoride | Dissolved fluoride, expressed as F–

H2S | Hydrogen sulphide

HCl | All inorganic gaseous chlorine compounds, expressed as HCl

HCN | Hydrogen cyanide

HF | All inorganic gaseous fluorine compounds, expressed as HF

Hg | The sum of mercury and its compounds, expressed as Hg

N2O | Dinitrogen monoxide (nitrous oxide)

NH3 | Ammonia

Ni | The sum of nickel and its compounds, expressed as Ni

NOX | The sum of nitrogen monoxide (NO) and nitrogen dioxide (NO2), expressed as NO2

Pb | The sum of lead and its compounds, expressed as Pb

PCDD/F | Polychlorinated dibenzo-p-dioxins and -furans

RCG | Raw concentration in the flue-gas. Concentration of SO2 in the raw flue-gas as a yearly average (under the standard conditions given under General considerations) at the inlet of the SOX abatement system, expressed at a reference oxygen content of 6 vol-% O2

Sb + As + Pb + Cr + Co + Cu + Mn + Ni + V | The sum of antimony, arsenic, lead, chromium, cobalt, copper, manganese, nickel, vanadium and their compounds, expressed as Sb + As + Pb + Cr + Co + Cu + Mn + Ni + V

SO2 | Sulphur dioxide

SO3 | Sulphur trioxide

SOX | The sum of sulphur dioxide (SO2) and sulphur trioxide (SO3), expressed as SO2

Sulphate | Dissolved sulphate, expressed as SO42–

Sulphide, easily released | The sum of dissolved sulphide and of those undissolved sulphides that are easily released upon acidification, expressed as S2–

Sulphite | Dissolved sulphite, expressed as SO32–

TOC | Total organic carbon, expressed as C (in water)

TSS | Total suspended solids. Mass concentration of all suspended solids (in water), measured via filtration through glass fibre filters and gravimetry

TVOC | Total volatile organic carbon, expressed as C (in air)

Zn | The sum of zinc and its compounds, expressed as Zn

For the purposes of these BAT conclusions, the following acronyms apply:

Acronym | Definition

ASU | Air supply unit

CCGT | Combined-cycle gas turbine, with or without supplementary firing

CFB | Circulating fluidised bed

CHP | Combined heat and power

COG | Coke oven gas

COS | Carbonyl sulphide

DLN | Dry low-NOX burners

DSI | Duct sorbent injection

ESP | Electrostatic precipitator

FBC | Fluidised bed combustion

FGD | Flue-gas desulphurisation

HFO | Heavy fuel oil

HRSG | Heat recovery steam generator

IGCC | Integrated gasification combined cycle

LHV | Lower heating value

LNB | Low-NOX burners

LNG | Liquefied natural gas

OCGT | Open-cycle gas turbine

OTNOC | Other than normal operating conditions

PC | Pulverised combustion

PEMS | Predictive emissions monitoring system

SCR | Selective catalytic reduction

SDA | Spray dry absorber

SNCR | Selective non-catalytic reduction

The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection.

Unless otherwise stated, these BAT conclusions are generally applicable.

Where emission levels associated with the best available techniques (BAT-AELs) are given for different averaging periods, all of those BAT-AELs have to be complied with.

The BAT-AELs set out in these BAT conclusions may not apply to liquid-fuel-fired and gas-fired turbines and engines for emergency use operated less than 500 h/yr, when such emergency use is not compatible with meeting the BAT-AELs.

Emission levels associated with the best available techniques (BAT-AELs) for emissions to air given in these BAT conclusions refer to concentrations, expressed as mass of emitted substance per volume of flue-gas under the following standard conditions: dry gas at a temperature of 273,15 K, and a pressure of 101,3 kPa, and expressed in the units mg/Nm3, μg/Nm3 or ng I-TEQ/Nm3.

The monitoring associated with the BAT-AELs for emissions to air is given in BAT 4

Reference conditions for oxygen used to express BAT-AELs in this document are shown in the table given below.

Activity | Reference oxygen level (OR)

Combustion of solid fuels | 6 vol-%

Combustion of solid fuels in combination with liquid and/or gaseous fuels

Waste co-incineration

Combustion of liquid and/or gaseous fuels when not taking place in a gas turbine or an engine | 3 vol-%

Combustion of liquid and/or gaseous fuels when taking place in a gas turbine or an engine | 15 vol-%

Combustion in IGCC plants

The equation for calculating the emission concentration at the reference oxygen level is:

ER21OR21OMEM

Where:

ERemission concentration at the reference oxygen level OR;

ORreference oxygen level in vol- %;

EMmeasured emission concentration;

OMmeasured oxygen level in vol- %.

For averaging periods, the following definitions apply:

[For any parameter where, due to sampling or analytical limitations, 30-minute measurement is inappropriate, a suitable sampling period is employed. For PCDD/F, a sampling period of 6 to 8 hours is used.]

Averaging period | Definition

Daily average | Average over a period of 24 hours of valid hourly averages obtained by continuous measurements

Yearly average | Average over a period of one year of valid hourly averages obtained by continuous measurements

Average over the sampling period | Average value of three consecutive measurements of at least 30 minutes each

Average of samples obtained during one year | Average of the values obtained during one year of the periodic measurements taken with the monitoring frequency set for each parameter

Emission levels associated with the best available techniques (BAT-AELs) for emissions to water given in these BAT conclusions refer to concentrations, expressed as mass of emitted substance per volume of water, and expressed in μg/l, mg/l, or g/l. The BAT-AELs refer to daily averages, i.e. 24-hour flow-proportional composite samples. Time-proportional composite samples can be used provided that sufficient flow stability can be demonstrated.

The monitoring associated with BAT-AELs for emissions to water is given in BAT 5

An energy efficiency level associated with the best available techniques (BAT-AEEL) refers to the ratio between the combustion unit's net energy output(s) and the combustion unit's fuel/feedstock energy input at actual unit design. The net energy output(s) is determined at the combustion, gasification, or IGCC unit boundaries, including auxiliary systems (e.g. flue-gas treatment systems), and for the unit operated at full load.

In the case of combined heat and power (CHP) plants:

the net total fuel utilisation BAT-AEEL refers to the combustion unit operated at full load and tuned to maximise primarily the heat supply and secondarily the remaining power that can be generated,

the net electrical efficiency BAT-AEEL refers to the combustion unit generating only electricity at full load.

BAT-AEELs are expressed as a percentage. The fuel/feedstock energy input is expressed as lower heating value (LHV).

The monitoring associated with BAT-AEELs is given in BAT 2

For the purposes of these BAT conclusions, when a range of values for the total rated thermal input is indicated, this is to be read as ‘equal to or greater than the lower end of the range and lower than the upper end of the range’. For example, the plant category 100–300 MWth is to be read as: combustion plants with a total rated thermal input equal to or greater than 100 MW and lower than 300 MW.

When a part of a combustion plant discharging flue-gases through one or more separate ducts within a common stack is operated less than 1500 h/yr, that part of the plant may be considered separately for the purpose of these BAT conclusions. For all parts of the plant, the BAT-AELs apply in relation to the total rated thermal input of the plant. In such cases, the emissions through each of those ducts are monitored separately.

The fuel-specific BAT conclusions included in Sections 2 to 7 apply in addition to the general BAT conclusions in this section.

BAT 1. In order to improve the overall environmental performance, BAT is to implement and adhere to an environmental management system (EMS) that incorporates all of the following features:

(i)

commitment of the management, including senior management;

(ii)

definition, by the management, of an environmental policy that includes the continuous improvement of the environmental performance of the installation;

(iii)

planning and establishing the necessary procedures, objectives and targets, in conjunction with financial planning and investment;

(iv)

implementation of procedures paying particular attention to:

(a)

structure and responsibility

(b)

recruitment, training, awareness and competence

(c)

communication

(d)

employee involvement

(e)

documentation

(f)

effective process control

(g)

planned regular maintenance programmes

(h)

emergency preparedness and response

(i)

safeguarding compliance with environmental legislation;

(v)

checking performance and taking corrective action, paying particular attention to:

(a)

monitoring and measurement (see also the JRC Reference Report on Monitoring of emissions to air and water from IED-installations — ROM)

(b)

corrective and preventive action

(c)

maintenance of records