Where public intervention and private storage legislation lay down detailed sampling procedures then those procedures shall be followed. In all other cases a sample of at least 3 sample units taken randomly from the consignment submitted to control shall be used. A composite sample may be prepared. The result obtained shall be compared with the legal limits by calculation of a 95 % confidence interval as 2 x standard deviation, where the relevant standard deviation depends on whether (1) the method is validated through international collaboration with values for σr and σR or (2) in the case of in-house validation, an internal reproducibility has been calculated. This confidence interval will then equate to the measurement uncertainty of the result.

In this case, the repeatability standard deviation σr and the reproducibility standard deviation σR have been established and the laboratory can demonstrate compliance with the performance characteristics of the validated method.

Calculate the arithmetic mean

x

of the n repeated measurements.

Calculate the expanded uncertainty (k = 2) of

x

as

U2 σ2Rn1n σ2r

If the final result x of measurement is calculated using a formula of the form x = y1 + y2, x = y1 – y2, x = y1 · y2 or x = y1/y2 the usual procedures for combining standard deviations in such cases shall be followed.

The consignment is judged to be not in compliance with the upper legal limit UL if

x

UUL;

otherwise it is judged to be in compliance with UL.

The consignment is judged to be not in compliance with the lower legal limit LL if

x

ULL;

otherwise it is judged to be in compliance with LL.

In cases where methods not specified in this Regulation are used and precision measures have not been established, an in-house validation shall be carried out. Internal repeatability standard deviation σir and the internal reproducibility standard deviation σiR shall be used instead of σr and σR, resp., in the formulae for the computation of the expanded uncertainty U.

The rules to be followed to determine compliance with the legal limit are as set out under point 1. However, if the consignment is judged to be non-compliant with the legal limit, the measurements shall be repeated with the method specified in this Regulation and the result evaluated in accordance to point 1.