Section 1.5.1 of Annex I to Directive 2006/42/EC, regarding the electricity supply, requires that machinery which has an electricity supply must be designed, constructed and equipped in such a way that all hazards of an electrical nature can be prevented. The power generator had the following shortcomings:
The exposed wiring between the ignition switch and the ignition mechanism of the petrol engine and the freely accessible 12 V battery could, in the event of a fault, cause an electric shock or a fire and short circuiting of the battery;
Although the operating panel of the generating set was covered with housing on the back, the cable entry (generator cable) and a break in the housing were designed in such a way that it was possible to reach live parts of the 230 V connections of the voltmeter and live parts of the heavy-duty power socket;
Some components of the control panel did not correspond to protection level IPX3;
Several earth wires were connected to one terminal connection on both the 400 V socket and the 230 V sockets;
The ends of the wires were tinned, and there were no wire-end ferrules which raised the risk of a potentially fatal electric shock in case the user touched a part of a product being at high voltage;
Except for the earth wire (two-colour GREEN/YELLOW combination) none of the wires were clearly identifiable. There was no connection plan which could be used to identify the wires;
The colour code used for different type of cables did not fulfill the requirements.