ANNEX III, Regulation (EU) 2015/1189

In forcesince 28 Apr 2015

1.

For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements and calculations shall be made using harmonised standards the reference numbers of which have been published for this purpose in the Official Journal of the European Union, or using other reliable, accurate and reproducible methods that take into account the generally recognised state-of-the-art methods. They shall meet the conditions and technical parameters set out in points 2 to 6.

(a)

Solid fuel boilers shall be tested for the preferred fuel and any other suitable fuels indicated in Table 1 of Annex II, with the exception that boilers tested for chipped wood with a moisture content of more than 35 % meeting the applicable requirements are considered to also meet such requirements for chipped wood with a moisture content of 15-35 % and are not required to be tested for chipped wood with a moisture content of 15-35 %.

(b)

Declared values for seasonal space heating energy efficiency and seasonal space heating emissions shall be rounded to the nearest integer.

(c)

Any solid fuel heat generator designed for a solid fuel boiler, and any solid fuel boiler housing to be equipped with such a heat generator, shall be tested with an appropriate solid fuel boiler housing and heat generator.

(a)

The useful efficiency values ηn, ηp and the useful heat output values Pn, Pp shall be measured, as appropriate. For solid fuel cogeneration boilers the electrical efficiency value ηel,n is also measured.

(b)

The seasonal space heating energy efficiency ηs shall be calculated as the seasonal space heating energy efficiency in active mode ηson, corrected by contributions accounting for temperature controls, auxiliary electricity consumption, and, for solid fuel cogeneration boilers, by adding the electrical efficiency multiplied by a conversion coefficient CC of 2,5.

(c)

The consumption of electricity shall be multiplied by a conversion coefficient CC of 2,5.

(a)

The seasonal space heating energy efficiency ηs is defined as:

ηs = ηson – F(1) – F(2) + F(3)

where:

(1)

ηson is the seasonal space heating energy efficiency in active mode expressed as a percentage, calculated as set out in point 4(b);

(2)

F(1) accounts for a loss of seasonal space heating energy efficiency due to adjusted contributions of temperature controls; F(1) = 3 %;

(3)

F(2) accounts for a negative contribution to the seasonal space heating energy efficiency by auxiliary electricity consumption, expressed as a percentage, and is calculated as set out in point 4(c);

(4)

F(3) accounts for a positive contribution to the seasonal space heating energy efficiency by the electrical efficiency of solid fuel cogeneration boilers, expressed as a percentage, and is calculated as follows:

F(3) = 2,5 × ηel,n

(b)

the seasonal space heating energy efficiency in active mode, ηson, is calculated as follows:

(1)

for manually stoked solid fuel boilers that can be operated at 50 % of the rated heat output in continuous mode, and for automatically stoked solid fuel boilers:

ηson = 0,85 × ηp + 0,15 × ηn

(2)

for manually stoked solid fuel boilers that cannot be operated at 50 % or less of the rated heat output in continuous mode, and for solid fuel cogeneration boilers:

ηson = ηn

(c)

F(2) is calculated as follows:

(1)

for manually stoked solid fuel boilers that can be operated at 50 % of the rated heat output in continuous mode, and for automatically stoked solid fuel boilers:

F(2) = 2,5 × (0,15 × elmax + 0,85 × elmin + 1,3 × PSB)/(0,15 × Pn + 0,85 × Pp)

(2)

for manually stoked solid fuel boilers that cannot be operated at 50 % or less of the rated heat output in continuous mode, and for solid fuel cogeneration boilers:

F(2) = 2,5 × (elmax + 1,3 × PSB)/Pn

The gross calorific value (GCV) shall be obtained from the gross calorific value moisture free (GCVmf) by applying the following conversion:

GCV = GCVmf × (1 – M)

where:

(a)

GCV and GCVmf are expressed in megajoules per kilogram;

(b)

M is the moisture content of the fuel, expressed as a proportion.

(a)

Emissions of particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides shall be expressed standardised to a dry flue gas basis at 10 % oxygen and standard conditions at 0 °C and 1013 millibar.

(b)

The seasonal space heating emissions Es of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides are calculated as follows:

(1)

for manually stoked solid fuel boilers that can be operated at 50 % of the rated heat output in continuous mode, and for automatically stoked solid fuel boilers:

Es = 0,85 × Es,p + 0,15 × Es,n

(2)

for manually stoked solid fuel boilers that cannot be operated at 50 % or less of the rated heat output in continuous mode, and for solid fuel cogeneration boilers:

Es = Es,n

where:

(a)

Es,p are the emissions of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides measured at 30 % or 50 % of rated heat output, as applicable;

(b)

Es,n are the emissions of respectively particulate matter, organic gaseous compounds, carbon monoxide and nitrogen oxides measured at rated heat output.

(c)

Emissions of particulate matter shall be measured by a gravimetric method excluding any particulate matter formed by organic gaseous compounds when flue gas is mixed with ambient air.

(d)

Emissions of nitrogen oxides shall be calculated as the sum of nitrogen monoxide and nitrogen dioxide, and expressed in nitrogen dioxide.