For the purposes of compliance and verification of compliance with the requirements of this Regulation, measurements and calculations shall be made using a reliable, accurate and reproducible method that take into account the generally recognised state-of-the-art measurement and calculation methods, including harmonised standards the reference numbers of which have been published for the purpose in the Official Journal of the European Union. They shall meet the technical definitions, conditions, equations and parameters set out in this Annex.
The energy consumption of a cavity of a domestic oven shall be measured for one standardised cycle, in a conventional mode and in a fan-forced mode, if available, by heating a standardised load soaked with water. It shall be verified that the temperature inside the oven cavity reaches the temperature setting of the thermostat and/or the oven control display within the duration of the test cycle. The energy consumption per cycle corresponding to the best performing mode (conventional mode or fan-forced mode) shall be used in the following calculations.
For each cavity of a domestic oven, the Energy Efficiency Index (EEIcavity) shall be calculated according to the following formulas:
for domestic electric ovens:
EEIcavityECelectric cavitySEC electric cavity 100
SECelectric cavity0,0042 V 0,55 (in kWh)
for domestic gas ovens:
EEIcavityECgas cavitySECgas cavity 100
SECgas cavity0,044 V 3,53 (in MJ)
Where:
—EEIcavityEnergy Efficiency Index for each cavity of a domestic oven, in %, rounded to the first decimal place,
—SECelectric cavityStandard Energy Consumption (electricity) required to heat a standardised load in a cavity of an electric heated domestic oven during a cycle, expressed in kWh, rounded to the second decimal place,
—SECgas cavityStandard Energy Consumption required to heat a standardised load in a cavity of a domestic gas-fired oven during a cycle, expressed in MJ, rounded to the second decimal place,
—VVolume of the cavity of the domestic oven in litres (L), rounded to the nearest integer,
—ECelectric cavityEnergy consumption required to heat a standardised load in a cavity of an electric heated domestic oven during a cycle, expressed in kWh, rounded to the second decimal place,
—ECgas cavityEnergy consumption required to heat a standardised load in a gas-fired cavity of a domestic oven during a cycle, expressed in MJ, rounded to the second decimal place.
The Energy Efficiency Index (EEIhood) is calculated as:
EEIhoodAEChoodSAEChood 100
and is rounded to the first decimal place.
Where:
SAEChood is the Standard Annual Energy consumption of the domestic range hood in kWh/a, rounded to the first decimal place,
AEChood is the Annual Energy Consumption of the domestic range hood in kWh/a, rounded to the first decimal place.
The Standard Annual Energy Consumption (SAEChood) of a domestic range hood shall be calculated as:
SAEChood0,55WBEP WL 15,3
Where:
WBEP is the electric power input of the domestic range hood at the best efficiency point, in Watt and rounded to the first decimal place,
WL is the nominal electric power input of the lighting system of the domestic range hood on the cooking surface, in Watt and rounded to the first decimal place.
The Annual Energy Consumption (AEChood) of a domestic range hood is calculated as:
for the fully automatic domestic range hoods:
AEChood
WBEPtHfWLtL
601000
Po1440tHf
2601000
Ps1440tHf
2601000
365
for all other domestic range hoods:
AEC hood
WBEPtH f WL tL
601000 365
Where:
tL is the average lighting time per day, in minutes (tL = 120),
tH is the average running time per day for domestic range hoods, in minutes (tH = 60),
Po is the electric power input in off-mode of the domestic range hood, in Watt and rounded to the second decimal place,
Ps is the electric power input in standby mode of the domestic range hood, in Watt and rounded to the second decimal place,
f is the time increase factor, calculated and rounded to the first decimal place, as:
f2FDEhood 3,6100
The Fluid Dynamic Efficiency (FDEhood) at the best efficiency point is calculated by the following formula, and is rounded to the first decimal place:
FDE hoodQBEP PBEP3600 WBEP 100
Where:
QBEP is the flow rate of the domestic range hood at best efficiency point, expressed in m3/h and rounded to the first decimal place,
PBEP is the static pressure difference of the domestic range hood at best efficiency point, expressed in Pa and rounded to the nearest integer,
WBEP is the electric power input of the domestic range hood at the best efficiency point, expressed in Watt and rounded to the first decimal place.
The Lighting Efficiency (LEhood) of a domestic range hood means the ratio between the average illumination and the nominal electric power input of the lighting system. It shall be calculated in lux per Watt and rounded at the nearest integer, as:
LE hoodEmiddleWL
Where:
Emiddle is the average illumination of the lighting system on the cooking surface measured under standard conditions, in lux and rounded to the nearest integer,
WL is the nominal electric power input of the lighting system of the domestic range hood on the cooking surface, in Watt and rounded to the first decimal place.
The Grease Filtering Efficiency (GFEhood) of a domestic range hood means the relative amount of grease retained within the range hood grease filters. It shall be calculated and rounded to the first decimal place as:
GFEhoodwgwr wt wg 100 %
Where:
—wgthe mass of oil in the grease filter, including all detachable coverings, in g and rounded to the first decimal place,
—wrthe mass of oil retained in the airways of the range hood, in g and rounded to the first decimal place,
—wtthe mass of oil retained in the absolute filter, in g and rounded to the first decimal place.
The Noise Value (in dB) is measured as the airborne acoustical A-weighted sound power emissions (weighted average value – LWA) of a domestic range hood at the highest setting for normal use, rounded to the nearest integer.