These BAT conclusions cover certain industrial activities specified in Section 1.2 of Annex I to Directive 2010/75/EU, namely ‘1.2. Refining of mineral oil and gas’.
In particular, these BAT conclusions cover the following processes and activities:
Activity | Subactivities or processes included in activity
Alkylation | All alkylation processes: hydrofluoric acid (HF), sulphuric acid (H2SO4) and solid-acid
Base oil production | Deasphalting, aromatic extraction, wax processing and lubricant oil hydrofinishing
Bitumen production | All techniques from storage to final product additives
Catalytic cracking | All types of catalytic cracking units such as fluid catalytic cracking
Catalytic reforming | Continuous, cyclic and semi-regenerative catalytic reforming
Coking | Delayed and fluid coking processes. Coke calcination
Cooling | Cooling techniques applied in refineries
Desalting | Desalting of crude oil
Combustion units for energy production | Combustion units burning refinery fuels, excluding units using only conventional or commercial fuels
Etherification | Production of chemicals (e.g. alcohols and ethers such as MTBE, ETBE and TAME) used as motor fuels additives
Gas separation | Separation of light fractions of the crude oil e.g. refinery fuel gas (RFG), liquefied petroleum gas (LPG)
Hydrogen consuming processes | Hydrocracking, hydrorefining, hydrotreatments, hydroconversion, hydroprocessing and hydrogenation processes
Hydrogen production | Partial oxidation, steam reforming, gas heated reforming and hydrogen purification
Isomerisation | Isomerisation of hydrocarbon compounds C4, C5 and C6
Natural gas plants | Natural gas (NG) processing including liquefaction of NG
Polymerisation | Polymerisation, dimerisation and condensation
Primary distillation | Atmospheric and vacuum distillation
Product treatments | Sweetening and final product treatments
Storage and handling of refinery materials | Storage, blending, loading and unloading of refinery materials
Visbreaking and other thermal conversions | Thermal treatments such as visbreaking or thermal gas oil process
Waste gas treatment | Techniques to reduce or abate emissions to air
Waste water treatment | Techniques to treat waste water prior to release
Waste management | Techniques to prevent or reduce the generation of waste
These BAT conclusions do not address the following activities or processes:
the exploration and production of crude oil and natural gas;
the transportation of crude oil and natural gas;
the marketing and distribution of products.
Other reference documents which may be relevant for the activities covered by these BAT conclusions are the following:
Reference document | Subject
Common Waste Water and Waste Gas Treatment/Management Systems in the Chemical Sector (CWW) | Waste water management and treatment techniques
Industrial Cooling Systems (ICS) | Cooling processes
Economics and Cross-media Effects (ECM) | Economics and cross-media effects of techniques
Emissions from Storage (EFS) | Storage, blending, loading and unloading of refinery materials
Energy Efficiency (ENE) | Energy efficiency and integrated refinery management
Large Combustion Plants (LCP) | Combustion of conventional and commercial fuels
Large Volume Inorganic Chemicals — Ammonia, Acids and Fertilisers Industries (LVIC-AAF) | Steam reforming and hydrogen purification
Large Volume Organic Chemical Industry (LVOC) | Etherification process (MTBE, ETBE and TAME production)
Waste Incineration (WI) | Waste incineration
Waste Treatment (WT) | Waste treatment
General Principles of Monitoring (MON) | Monitoring of emissions to air and water
The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection.
Unless otherwise stated, these BAT conclusions are generally applicable.
Unless stated otherwise, emission levels associated with the best available techniques (BAT-AELs) for emissions to air given in these BAT conclusions refer to concentrations, expressed as mass of emitted substance per volume of waste gas under the following standard conditions: dry gas, temperature of 273,15 K, pressure of 101,3 kPa.
For continuous measurements | BAT-AELs refer to monthly average values, which are the averages of all valid hourly average values measured over a period of one month
For periodic measurements | BAT-AELs refer to the average value of three spot samples of at least 30 minutes each
For combustion units, catalytic cracking processes, and waste gas sulphur recovery units, reference conditions for oxygen are shown in Table 1.
[In case of applying BAT 58.]
Activities | Unit | Oxygen reference conditions
Combustion unit using liquid or gaseous fuels with the exception of gas turbines and engines | mg/Nm3 | 3 % oxygen by volume
Combustion unit using solid fuels | mg/Nm3 | 6 % oxygen by volume
Gas turbines (including combined cycle gas turbines — CCGT) and engines | mg/Nm3 | 15 % oxygen by volume
Catalytic cracking process (regenerator) | mg/Nm3 | 3 % oxygen by volume
Waste gas sulphur recovery unit | mg/Nm3 | 3 % oxygen by volume
The formula for calculating the emissions concentration at a reference oxygen level (see Table 1) is shown below.
ER21OR21OMEM
Where:
ER (mg/Nm3)emissions concentration referred to the reference oxygen level OR
OR (vol %)reference oxygen level
EM (mg/Nm3)emissions concentration referred to the measured oxygen level OM
OM (vol %)measured oxygen level.
Unless stated otherwise, emission levels associated with the best available techniques (BAT-AELs) for emissions to water given in these BAT conclusions refer to values of concentration (mass of emitted substances per volume of water) expressed in mg/l.
Unless stated otherwise, the averaging periods associated with the BAT-AELs are defined as follows:
Daily average | Average over a sampling period of 24 hours taken as a flow-proportional composite sample or, provided that sufficient flow stability is demonstrated, from a time-proportional sample
Yearly/Monthly average | Average of all daily averages obtained within a year/month, weighted according to the daily flows
For the purpose of these BAT conclusions, the following definitions apply:
Term used | Definition
Unit | A segment/subpart of the installation in which a specific processing operation is conducted
New unit | A unit first permitted on the site of the installation following the publication of these BAT conclusions or a complete replacement of a unit on the existing foundations of the installation following the publication of these BAT conclusions
Existing unit | A unit which is not a new unit
Process off-gas | The collected gas generated by a process which must be treated e.g. in an acid gas removal unit and a sulphur recovery unit (SRU)
Flue-gas | The exhaust gas exiting a unit after an oxidation step, generally combustion (e.g. regenerator, Claus unit)
Tail gas | Common name of the exhaust gas from an SRU (generally Claus process)
VOC | Volatile organic compounds as defined in Article 3(45) of Directive 2010/75/EU
NMVOC | VOC excluding methane
Diffuse VOC emissions | Non-channelled VOC emissions that are not released via specific emission points such as stacks. They can result from ‘area’ sources (e.g. tanks) or ‘point’ sources (e.g. pipe flanges)
NOX expressed as NO2 | The sum of nitrogen oxide (NO) and nitrogen dioxide (NO2) expressed as NO2
SOX expressed as SO2 | The sum of sulphur dioxide (SO2) and sulphur trioxide (SO3) expressed as SO2
H2S | Hydrogen sulphide. Carbonyl sulphide and mercaptan are not included
Hydrogen chloride expressed as HCl | All gaseous chlorides expressed as HCl
Hydrogen fluoride expressed as HF | All gaseous fluorides expressed as HF
FCC unit | Fluid catalytic cracking: a conversion process for upgrading heavy hydrocarbons, using heat and a catalyst to break larger hydrocarbon molecules into lighter molecules
SRU | Sulphur recovery unit. See definition in Section 1.20.3
Refinery fuel |
Solid, liquid or gaseous combustible material from the distillation and conversion steps of the refining of crude oil.
Examples are refinery fuel gas (RFG), syngas and refinery oils, pet coke
RFG | Refinery fuel gas: off-gases from distillation or conversion units used as a fuel
Combustion unit | Unit burning refinery fuels alone or with other fuels for the production of energy at the refinery site, such as boilers (except CO boilers), furnaces, and gas turbines.
Continuous measurement | Measurement using an ‘automated measuring system’ (AMS) or a ‘continuous emission monitoring system’ (CEMS) permanently installed on site
Periodic measurement | Determination of a measurand at specified time intervals using manual or automated reference methods
Indirect monitoring of emissions to air | Estimation of the emissions concentration in the flue-gas of a pollutant obtained through an appropriate combination of measurements of surrogate parameters (such as O2 content, sulphur or nitrogen content in the feed/fuel), calculations and periodic stack measurements. The use of emission ratios based on S content in the fuel is one example of indirect monitoring. Another example of indirect monitoring is the use of PEMS
Predictive Emissions monitoring system (PEMS) | System to determine the emissions concentration of a pollutant based on its relationship with a number of characteristic continuously monitored process parameters (e.g. fuel-gas consumption, air/fuel ratio) and fuel or feed quality data (e.g. the sulphur content) of an emission source
Volatile liquid hydrocarbon compounds | Petroleum derivatives with a Reid vapour pressure (RVP) of more than 4 kPa, such as naphtha and aromatics
Recovery rate | Percentage of NMVOC recovered from the streams conveyed into a vapour recovery unit (VRU)
The process-specific BAT conclusions included in Sections 1.2 to 1.19 apply in addition to the general BAT conclusions mentioned in this section.
BAT 1. In order to improve the overall environmental performance of plants for the refining of mineral oil and gas, BAT is to implement and adhere to an environmental management system (EMS) that incorporates all of the following features:
commitment of the management, including senior management;
definition of an environmental policy that includes the continuous improvement for the installation by the management;
planning and establishing the necessary procedures, objectives and targets, in conjunction with financial planning and investment;
implementation of the procedures paying particular attention to:
structure and responsibility
training, awareness and competence
communication
employee involvement
documentation
efficient process control
maintenance programmes
emergency preparedness and response
safeguarding compliance with environmental legislation.
checking performance and taking corrective action, paying particular attention to:
monitoring and measurement (see also the reference document on the General Principles of Monitoring)
corrective and preventive action
maintenance of records
independent (where practicable) internal and external auditing in order to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained;
review of the EMS and its continuing suitability, adequacy and effectiveness by senior management;
following the development of cleaner technologies;
consideration for the environmental impacts from the eventual decommissioning of the installation at the stage of designing a new plant, and throughout its operating life;
application of sectoral benchmarking on a regular basis.
The scope (e.g. level of detail) and nature of the EMS (e.g. standardised or non-standardised) will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have.
BAT 2. In order to use energy efficiently, BAT is to use an appropriate combination of the techniques given below.
Technique | Description
Design techniques
Pinch analysis
Methodology based on a systematic calculation of thermodynamic targets for minimising energy consumption of processes. Used as a tool for the evaluation of total systems designs
Heat integration
Heat integration of process systems ensures that a substantial proportion of the heat required in various processes is provided by exchanging heat between streams to be heated and streams to be cooled
Heat and power recovery
Use of energy recovery devices e.g.:
waste heat boilers
expanders/power recovery in the FCC unit
use of waste heat in district heating
Process control and maintenance techniques
Process optimisation
Automated controlled combustion in order to lower the fuel consumption per tonne of feed processed, often combined with heat integration for improving furnace efficiency
Management and reduction of steam consumption
Systematic mapping of drain valve systems in order to reduce steam consumption and optimise its use
Use of energy benchmark
Participation in ranking and benchmarking activities in order to achieve continuous improvement by learning from best practice
Energy-efficient production techniques
Use of combined heat and power
System designed for the co-production (or the cogeneration) of heat (e.g. steam) and electric power from the same fuel
Integrated gasification combined cycle (IGCC)
Technique whose purpose is to produce steam, hydrogen (optional) and electric power from a variety of fuel types (e.g. heavy fuel oil or coke) with a high conversion efficiency
BAT 3. In order to prevent or, where that is not practicable, to reduce dust emissions from the storage and handling of dusty materials, BAT is to use one or a combination of the techniques given below:
store bulk powder materials in enclosed silos equipped with a dust abatement system (e.g. fabric filter);
store fine materials in enclosed containers or sealed bags;
keep stockpiles of coarse dusty material wetted, stabilise the surface with crusting agents, or store under cover in stockpiles;
use road cleaning vehicles.
BAT 4. BAT is to monitor emissions to air by using the monitoring techniques with at least the minimum frequency given below and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.
[Continuous measurement of SO2 emissions may be replaced by calculations based on measurements of the sulphur content of the fuel or the feed; where it can be demonstrated that this leads to an equivalent level of accuracy.] [Regarding SOX, only SO2 is continuously measured, while SO3 is only periodically measured (e.g. during calibration of the SO2 monitoring system).] [Refers to the total rated thermal input of all combustion units connected to the stack where emissions occur.] [Or indirect monitoring of SOX.] [Monitoring frequencies may be adapted if, after a period of one year, the data series clearly demonstrate a sufficient stability.] [SO2 emissions measurements from SRU may be replaced by a continuous material balance or other relevant process parameter monitoring, provided appropriate measurements of SRU efficiency are based on periodic (e.g. once every 2 years) plant performance tests.] [Antimony (Sb) is monitored only in catalytic cracking units when Sb injection is used in the process (e.g. for metals passivation).] [With the exception of combustion units firing only gaseous fuels.]
Description | Unit | Minimum frequency | Monitoring technique
SOX, NOX, and dust emissions
Catalytic cracking | Continuous | Direct measurement
Combustion units
≥ 100 MW
and calcining units
Continuous | Direct measurement
Combustion units
of 50 to 100 MW
Continuous | Direct measurement or indirect monitoring
Combustion units
< 50 MW
Once a year and after significant fuel changes | Direct measurement or indirect monitoring
Sulphur recovery units (SRU) | Continuous for SO2 only | Direct measurement or indirect monitoring
NH3 emissions
All units equipped with SCR or SNCR | Continuous | Direct measurement
CO emissions
Catalytic cracking and combustion units
≥ 100 MW
Continuous | Direct measurement
Other combustion units | Once every 6 months | Direct measurement
Metals emissions: Nickel (Ni), Antimony (Sb), Vanadium (V)
Catalytic cracking | Once every 6 months and after significant changes to the unit | Direct measurement or analysis based on metals content in the catalyst fines and in the fuel
Combustion units
Polychlorinated dibenzodioxins/furans (PCDD/F) emissions
Catalytic reformer | Once a year or once a regeneration, whichever is longer | Direct measurement
BAT 5. BAT is to monitor the relevant process parameters linked to pollutant emissions, at catalytic cracking and combustion units by using appropriate techniques and with at least the frequency given below.
[N and S monitoring in fuel or feed may not be necessary when continuous emission measurements of NOX and SO2 are carried out at the stack.]
Description | Minimum frequency
Monitoring of parameters linked to pollutant emissions, e.g. O2 content in flue-gas, N and S content in fuel or feed |
Continuous for O2 content.
For N and S content, periodic at a frequency based on significant fuel/feed changes
BAT 6. BAT is to monitor diffuse VOC emissions to air from the entire site by using all of the following techniques:
sniffing methods associated with correlation curves for key equipment;
optical gas imaging techniques;
calculations of chronic emissions based on emissions factors periodically (e.g. once every two years) validated by measurements.
The screening and quantification of site emissions by periodic campaigns with optical absorption-based techniques, such as differential absorption light detection and ranging (DIAL) or solar occultation flux (SOF) is a useful complementary technique.
See Section 1.20.6.
BAT 7. In order to prevent or reduce emissions to air, BAT is to operate the acid gas removal units, sulphur recovery units and all other waste gas treatment systems with a high availability and at optimal capacity.
Special procedures can be defined for other than normal operating conditions, in particular:
during start-up and shutdown operations;
during other circumstances that could affect the proper functioning of the systems (e.g. regular and extraordinary maintenance work and cleaning operations of the units and/or of the waste gas treatment system);
in case of insufficient waste gas flow or temperature which prevents the use of the waste gas treatment system at full capacity.
BAT 8. In order to prevent and reduce ammonia (NH3) emissions to air when applying selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) techniques, BAT is to maintain suitable operating conditions of the SCR or SNCR waste gas treatment systems, with the aim of limiting emissions of unreacted NH3.
BAT-associated emission levels: See Table 2.
[The higher end of the range is associated with higher inlet NOX concentrations, higher NOX reduction rates and the ageing of the catalyst.] [The lower end of the range is associated with the use of the SCR technique.]
Parameter |
BAT-AEL
z(monthly average)
mg/Nm3
Ammonia expressed as NH3 | < 5 – 15
BAT 9. In order to prevent and reduce emissions to air when using a sour water steam stripping unit, BAT is to route the acid off-gases from this unit to an SRU or any equivalent gas treatment system.
It is not BAT to directly incinerate the untreated sour water stripping gases.
BAT 10. BAT is to monitor emissions to water by using the monitoring techniques with at least the frequency given in Table 3) and in accordance with EN standards. If EN standards are not available, BAT is to use ISO, national or other international standards that ensure the provision of data of an equivalent scientific quality.
BAT 11. In order to reduce water consumption and the volume of contaminated water, BAT is to use all of the techniques given below.
Technique | Description | Applicability
Water stream integration
Reduction of process water produced at the unit level prior to discharge by the internal reuse of water streams from e.g. cooling, condensates, especially for use in crude desalting | Generally applicable for new units. For existing units, applicability may require a complete rebuilding of the unit or the installation
Water and drainage system for segregation of contaminated water streams
Design of an industrial site to optimise water management, where each stream is treated as appropriate, by e.g. routing generated sour water (from distillation, cracking, coking units, etc.) to appropriate pretreatment, such as a stripping unit | Generally applicable for new units. For existing units, applicability may require a complete rebuilding of the unit or the installation
Segregation of non-contaminated water streams (e.g. once-through cooling, rain water)
Design of a site in order to avoid sending non-contaminated water to general waste water treatment and to have a separate release after possible reuse for this type of stream |
Generally applicable for new units.
For existing units, applicability may require a complete rebuilding of the unit or the installation
Prevention of spillages and leaks
Practices that include the utilisation of special procedures and/or temporary equipment to maintain performances when necessary to manage special circumstances such as spills, loss of containment, etc. | Generally applicable
BAT 12. In order to reduce the emission load of pollutants in the waste water discharge to the receiving water body, BAT is to remove insoluble and soluble polluting substances by using all of the techniques given below.
Technique | Description | Applicability
Removal of insoluble substances by recovering oil
See Section 1.21.2 | Generally applicable
Removal of insoluble substances by recovering suspended solids and dispersed oil
See Section 1.21.2 | Generally applicable
Removal of soluble substances including biological treatment and clarification
See Section 1.21.2 | Generally applicable
BAT-associated emission levels: See Table 3.
BAT 13. When further removal of organic substances or nitrogen is needed, BAT is to use an additional treatment step as described in Section 1.21.2.