1.
For the purposes of compliance and verification of compliance with the requirements of this Regulation, calculations shall be made using harmonised standards the reference numbers of which have been published for this purpose in the Official Journal of the European Union, or using other appropriate calculation methods that take into account the generally recognised state-of-the-art methods. They shall meet the technical parameters and calculations set out in points 2 to 6.
Technical parameters used for the calculations shall be measured in accordance with Annex VII.
The following parameters shall be calculated for water heaters under average climate conditions:
the water heating energy efficiency ηwh in %, rounded to one decimal place;
the annual electricity consumption AEC in kWh in terms of final energy, rounded to the nearest integer;
in addition, for water heaters using fuels under average climate conditions:
the annual fuel consumption AFC in kWh in terms of GCV, rounded to the nearest integer;
in addition, for solar water heaters under average climate conditions:
the heat generator water heating energy efficiency ηwh,nonsol in %, rounded to one decimal place;
the annual auxiliary electricity consumption Qaux in kWh in terms of final energy, rounded to one decimal place;
in addition, for solar water heaters and heat pump water heaters under colder and warmer climate conditions:
the parameters set out in points (a) to (c);
in addition for solar water heaters under average, colder and warmer climate conditions:
the annual non-solar heat contribution Qnonsol in kWh in terms of primary energy for electricity and/or in kWh in terms of GCV for fuels, rounded to one decimal place.
Conventional water heaters and heat pump water heaters:
The water heating energy efficiency is calculated as follows:
ηwhQrefQfuel CC Qelec1 SCF smart Qcor
For water-/brine-to-water heat pump water heaters, the electricity consumption of one or more ground water pumps shall be taken into account.
Solar water heaters:
The water heating energy efficiency is calculated as follows:
ηwh0,6 366 QrefQtota
Where:
QtotaQnonsol1,1 ηwh,nonsol 0,1 Qaux CC
Conventional water heaters and heat pump water heaters:
The annual electricity consumption AEC in kWh in terms of final energy is calculated as follows:
AEC0,6 366Qelec1 SCF smartQcorCC
The annual fuel consumption AFC in GJ in terms of GCV is calculated as follows:
AFC0,6 366Qfuel1 SCF smart Qcor
Solar water heaters:
The annual electricity consumption AEC in kWh in terms of final energy is calculated as follows:
AECCC QelecQfuel CC QelecQtotaCC
The annual fuel consumption AFC in GJ in terms of GCV is calculated as follows:
AFCQfuelQfuel CC Qelec Qtota
The smart control factor is calculated as follows:
SCF1Qfuel,week,smart CC Qelec,week,smartQfuel,week CC Qelec,week
If SCF ≥ 0,07, the value of smart shall be 1. In all other cases, the value of smart shall be 0.
The ambient correction term is calculated as follows:
for conventional water heaters using electricity:
Qcor kCCQelec1 SCF smart Qref
for conventional water heaters using fuels:
Qcor kQfuel1 SCF smart Qref
for heat pump water heaters:
Qcor k 24h Pstby
Where:
the k-values are given in Table 8 for each load profile.
3XS | XXS | XS | S | M | L | XL | XXL
k | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,23 | 0,0