The rate of recycled lead content is calculated as follows:
RPb = Σ mPb outputmPb input × 100, [mass %]
where:
RPbcalculated rate of recycled lead (Pb) from a recycling process for the purpose of Article 12(4) of Directive 2006/66/EC [in mass %];
mPb outputthe mass of Pb in output fractions accounting for recycling is the share of Pb contained in these fractions which results from the recycling of lead-acid batteries and accumulators per calendar year [in tonnes];
mPb inputthe mass of Pb in the input fraction entering the battery recycling process is defined as the yearly average Pb content of waste lead-acid batteries and accumulators multiplied by the input mass of lead-acid batteries and accumulators per calendar year [in tonnes].
In the output fraction the lead (Pb) contained in slag at the end of the recycling process is not accounted for the rate of recycled lead content.