These BAT conclusions concern the industrial activities specified in Annex I to Directive 2010/75/EU, namely:
3.3. Manufacture of glass including glass fibre with a melting capacity exceeding 20 tonnes per day;
3.4. Melting mineral substances including the production of mineral fibres with a melting capacity exceeding 20 tonnes per day.
These BAT conclusions do not address the following activities:
Production of water glass, covered by the reference document Large Volume Inorganic Chemicals – Solids and Other Industry (LVIC-S)
Production of polycrystalline wool
Production of mirrors, covered by the reference document Surface Treatment Using Organic Solvents (STS)
Other reference documents which are of relevance for the activities covered by these BAT conclusions are the following:
Reference documents | Activity
Emissions from Storage (EFS) | Storage and handling of raw materials
Energy Efficiency (ENE) | General energy efficiency
Economic and Cross-Media Effects (ECM) | Economics and cross-media effects of techniques
General Principles of Monitoring (MON) | Emissions and consumption monitoring
The techniques listed and described in these BAT conclusions are neither prescriptive nor exhaustive. Other techniques may be used that ensure at least an equivalent level of environmental protection.
For the purposes of these BAT conclusions, the following definitions apply:
Term used | Definition
New plant | A plant introduced on the site of the installation following the publication of these BAT conclusions or a complete replacement of a plant on the existing foundations of the installation following the publication of these BAT conclusions
Existing plant | A plant which is not a new plant
New furnace | A furnace introduced on the site of the installation following the publication of these BAT conclusions or a complete rebuild of a furnace following the publication of these BAT conclusions
Normal furnace rebuild | A rebuild between campaigns without a significant change in furnace requirements or technology and in which the furnace frame is not significantly adjusted and the furnace dimensions remain basically unchanged. The refractory of the furnace and, where appropriate, the regenerators are repaired by the full or partial replacement of the material.
Complete furnace rebuild | A rebuild involving a major change in the furnace requirements or technology and with major adjustment or replacement of the furnace and associated equipments.
Unless stated otherwise, emission levels associated with the best available techniques (BAT-AELs) for air emissions given in these BAT conclusions apply under the reference conditions shown in Table 1. All values for concentrations in waste gases refer to standard conditions: dry gas, temperature 273,15 K, pressure 101,3 kPa.
For discontinuous measurements | BAT-AELs refer to the average value of three spot samples of at least 30 minutes each; for regenerative furnaces the measuring period should cover a minimum of two firing reversals of the regenerator chambers
For continuous measurements | BAT-AELs refer to daily average values
Activities | Unit | Reference conditions
Melting activities | Conventional melting furnace in continuous melters | mg/Nm3 | 8 % oxygen by volume
Conventional melting furnace in discontinuous melters | mg/Nm3 | 13 % oxygen by volume
Oxy-fuel-fired furnaces | kg/tonne melted glass | The expression of emission levels measured as mg/Nm3 to a reference oxygen concentration is not applicable
Electric furnaces |
mg/Nm3
or
kg/tonne melted glass
The expression of emission levels measured as mg/Nm3 to a reference oxygen concentration is not applicable
Frit melting furnaces |
mg/Nm3
or
kg/tonne melted frit
Concentrations refer to 15 % oxygen by volume.
When air-gas firing is used, BAT AELs expressed as emission concentration (mg/Nm3) apply.
When only oxy-fuel firing is employed, BAT AELs expressed as specific mass emissions (kg/tonne melted frit) apply.
When oxygen-enriched air-fuel firing is used, BAT AELs expressed as either emission concentration (mg/Nm3) or as specific mass emissions (kg/tonne melted frit) apply
All type of furnaces | kg/tonne melted glass | The specific mass emissions refer to 1 tonne of melted glass
Non-melting activities, including downstream processes | All processes | mg/Nm3 | No correction for oxygen
All processes | kg/tonne glass | The specific mass emissions refer to 1 tonne of produced glass
The formula for calculating the emissions concentration at a reference oxygen level (see Table 1) is shown below.
ER = 21 – OR21 – OM × EM
Where:
ER (mg/Nm3)emissions concentration corrected to the reference oxygen level OR
OR (vol %)reference oxygen level
EM (mg/Nm3)emissions concentration referred to the measured oxygen level OM
OM (vol %)measured oxygen level.
BAT-AELs given in Sections 1.2 to 1.9 as specific mass emissions (kg/tonne melted glass) are based on the calculation reported below except for oxy-fuel fired furnaces and, in a limited number of cases, for electric melting where BAT-AELs given in kg/tonne melted glass were derived from specific reported data.
The calculation procedure used for the conversion from concentrations to specific mass emissions is shown below.
Specific mass emission (kg/tonne of melted glass) = conversion factor × emissions concentration (mg/Nm3)
Where: conversion factor = (Q/P) × 10–6
with
Qwaste gas volume in Nm3/h
Ppull rate in tonnes of melted glass/h.
The waste gas volume (Q) is determined by the specific energy consumption, type of fuel, and the oxidant (air, air enriched by oxygen and oxygen with purity depending on the production process). The energy consumption is a complex function of (predominantly) the type of furnace, the type of glass and the cullet percentage.
However, a range of factors can influence the relationship between concentration and specific mass flow, including:
type of furnace (air preheating temperature, melting technique)
type of glass produced (energy requirement for melting)
energy mix (fossil fuel/electric boosting)
type of fossil fuel (oil, gas)
type of oxidant (oxygen, air, oxygen-enriched air)
cullet percentage
batch composition
age of the furnace
furnace size.
The conversion factors given in Table 2 have been used for converting BAT-AELs from concentrations into specific mass emissions.
The conversion factors have been determined on the basis of energy efficient furnaces and relate only to full air/fuel-fired furnaces.
[Specific cases correspond to less favourable cases (i.e. small special furnaces with a production of generally below 100 tonnes/day and a cullet rate of below 30 %). This category represents only 1 or 2 % of the container glass production.] [Specific cases corresponding to less favourable cases and/or non-soda-lime glasses: borosilicates, glass ceramic, crystal glass and, less frequently, lead crystal glass.]
Sectors | Factors to convert mg/Nm3 into kg/tonne of melted glass
Flat glass | 2,5 × 10–3
Container glass | General case | 1,5 × 10–3
Specific cases |
Case-by-case study
(often 3,0 × 10–3)
Continuous filament glass fibre | 4,5 × 10–3
Domestic glass | Soda lime | 2,5 × 10–3
Specific cases |
Case-by-case study
(between 2,5 and > 10 × 10–3; often 3,0 × 10–3)
Mineral wool | Glass wool | 2 × 10–3
Stone wool cupola | 2,5 × 10–3
Special glass | TV glass (panels) | 3 × 10–3
TV glass (funnel) | 2,5 × 10–3
Borosilicate (tube) | 4 × 10–3
Glass ceramics | 6,5 × 10–3
Lighting glass (soda-lime) | 2,5 × 10–3
Frits |
Case-by-case study
(between 5 – 7,5 × 10–3)
For the purpose of these BAT conclusions and for the BAT-AELs reported in Sections 1.2 to 1.9, the following definitions apply:
NOX expressed as NO2 | The sum of nitrogen oxide (NO) and nitrogen dioxide (NO2) expressed as NO2
SOX expressed as SO2 | The sum of sulphur dioxide (SO2) and sulphur trioxide (SO3) expressed as SO2
Hydrogen chloride expressed as HCl | All gaseous chlorides expressed as HCl
Hydrogen fluoride expressed as HF | All gaseous fluorides expressed as HF
Unless stated otherwise, emission levels associated with the best available techniques (BAT-AELs) for waste water emissions given in these BAT conclusions refer to the average value of a composite sample taken over a period of 2 hours or 24 hours.
Unless otherwise stated, the BAT conclusions presented in this section can be applied to all installations.
The process-specific BAT included in Sections 1.2 – 1.9 apply in addition to the general BAT mentioned in this section.
1.
BAT is to implement and adhere to an environmental management system (EMS) that incorporates all of the following features:
commitment of the management, including senior management;
definition of an environmental policy that includes the continuous improvement for the installation by the management;
planning and establishing the necessary procedures, objectives and targets, in conjunction with financial planning and investment;
implementation of the procedures paying particular attention to:
structure and responsibility
training, awareness and competence
communication
employee involvement
documentation
efficient process control
maintenance programmes
emergency preparedness and response
safeguarding compliance with environmental legislation.
checking performance and taking corrective action, paying particular attention to:
monitoring and measurement (see also the reference document on the General Principles of Monitoring)
corrective and preventive action
maintenance of records
independent (where practicable) internal or external auditing in order to determine whether or not the EMS conforms to planned arrangements and has been properly implemented and maintained;
review of the EMS and its continuing suitability, adequacy and effectiveness by senior management;
following the development of cleaner technologies;
consideration for the environmental impacts from the eventual decommissioning of the installation at the stage of designing a new plant, and throughout its operating life;
application of sectoral benchmarking on a regular basis.
The scope (e.g. level of details) and nature of the EMS (e.g. standardised or non-standardised) will generally be related to the nature, scale and complexity of the installation, and the range of environmental impacts it may have.
2.
BAT is to reduce the specific energy consumption by using one or a combination of the following techniques:
Technique | Applicability
Process optimisation, through the control of the operating parameters
The techniques are generally applicable
Regular maintenance of the melting furnace
Optimisation of the furnace design and the selection of the melting technique
Applicable for new plants.
For existing plants, the implementation requires a complete rebuild of the furnace
Application of combustion control techniques
Applicable to fuel/air and oxy-fuel fired furnaces
Use of increasing levels of cullet, where available and economically and technically viable
Not applicable to the continuous filament glass fibre, high temperature insulation wool and frits sectors
Use of a waste heat boiler for energy recovery, where technically and economically viable
Applicable to fuel/air and oxy-fuel fired furnaces.
The applicability and economic viability of the technique is dictated by the overall efficiency that may be obtained, including the effective use of the steam generated
Use of batch and cullet preheating, where technically and economically viable
Applicable to fuel/air and oxy-fuel fired furnaces.
The applicability is normally restricted to batch compositions with more than 50 % cullet
3.
BAT is to prevent, or where that is not practicable, to reduce diffuse dust emissions from the storage and handling of solid materials by using one or a combination of the following techniques:
Storage of raw materials
Store bulk powder materials in enclosed silos equipped with a dust abatement system (e.g. fabric filter)
Store fine materials in enclosed containers or sealed bags
Store under cover stockpiles of coarse dusty materials
Use of road cleaning vehicles and water damping techniques
Handling of raw materials
Technique | Applicability
For materials which are transported by above ground, use enclosed conveyors to prevent material loss
The techniques are generally applicable
Where pneumatic conveying is used, apply a sealed system equipped with a filter to clean the transport air before release
Moistening of the batch
The use of this technique is limited by the negative consequences on the furnace energy efficiency. Restrictions may apply to some batch formulations, in particular for borosilicate glass production
Application of a slightly negative pressure within the furnace
Applicable only as an inherent aspect of operation (i.e. melting furnaces for frits production) due to a detrimental impact on furnace energy efficiency
Use of raw materials that do not cause decrepitation phenomena (mainly dolomite and limestone). These phenomena consist of minerals that ‘crackle’ when exposed to heat, with a consequent potential increase of dust emissions
Applicable within the constraints associated with the availability of raw materials
Use of an extraction which vents to a filter system in processes where dust is likely to be generated (e.g. bag opening, frits batch mixing, fabric filter dust disposal, cold-top melters)
The techniques are generally applicable
Use of enclosed screw feeders
Enclosure of feed pockets
Generally applicable. Cooling may be necessary to avoid damage to the equipment
4.
BAT is to prevent, or where that is not practicable, to reduce diffuse gaseous emissions from the storage and handling of volatile raw materials by using one or a combination of the following techniques:
Use of tank paint with low solar absorbency for bulk storage subject to temperature changes due to solar heating.
Control of temperature in the storage of volatile raw materials.
Tank insulation in the storage of volatile raw materials.
Inventory management
Use of floating roof tanks in the storage of large quantities of volatile petroleum products.
Use of vapour return transfer systems in the transfer of volatile fluids (e.g. from tank trucks to storage tank).
Use of bladder roof tanks in the storage of liquid raw materials.
Use of pressure/vacuum valves in tanks designed to withstand pressure fluctuations.
Application of a release treatment (e.g. adsorption, absorption, condensation) in the storage of hazardous materials.
Application of subsurface filling in the storage of liquids that tend to foam.
5.
BAT is to reduce energy consumption and emissions to air by carrying out a constant monitoring of the operational parameters and a programmed maintenance of the melting furnace.
Technique | Applicability
The technique consists of a series of monitoring and maintenance operations which can be used individually or in combination appropriate to the type of furnace, with the aim of minimising the ageing effects on the furnace, such as sealing the furnace and burner blocks, keep the maximum insulation, control the stabilised flame conditions, control the fuel/air ratio, etc. |
Applicable to regenerative, recuperative, and oxy-fuel fired furnaces.
The applicability to other types of furnaces requires an installation-specific assessment
6.
BAT is to carry out a careful selection and control of all substances and raw materials entering the melting furnace in order to reduce or prevent emissions to air by using one or a combination of the following techniques.
Technique | Applicability
Use of raw materials and external cullet with low levels of impurities (e.g. metals, chlorides, fluorides)
Applicable within the constraints of the type of glass produced at the installation and the availability of raw materials and fuels
Use of alternative raw materials (e.g. less volatile)
Use of fuels with low metal impurities
7.
BAT is to carry out monitoring of emissions and/or other relevant process parameters on a regular basis, including the following:
Technique | Applicability
Continuous monitoring of critical process parameters to ensure process stability, e.g. temperature, fuel feed and airflow
The techniques are generally applicable
Regular monitoring of process parameters to prevent/reduce pollution, e.g. O2 content of the combustion gases to control the fuel/air ratio.
Continuous measurements of dust, NOX and SO2 emissions or discontinuous measurements at least twice per year, associated with the control of surrogate parameters to ensure that the treatment system is working properly between measurements
Continuous or regular periodic measurements of NH3 emissions, when selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) techniques are applied
The techniques are generally applicable
Continuous or regular periodic measurements of CO emissions when primary techniques or chemical reduction by fuel techniques are applied for NOX emissions reductions or partial combustion may occur.
Regular periodic measurements of emissions of HCl, HF, CO and metals, in particular when raw materials containing such substances are used or partial combustion may occur
The techniques are generally applicable
Continuous monitoring of surrogate parameters to ensure that the waste gas treatment system is working properly and that the emission levels are maintained between discontinuous measurements. The monitoring of surrogate parameters includes: reagent feed, temperature, water feed, voltage, dust removal, fan speed, etc.
8.
BAT is to operate the waste gas treatment systems during normal operating conditions at optimal capacity and availability in order to prevent or reduce emissions
Special procedures can be defined for specific operating conditions, in particular:
during start-up and shutdown operations
during other special operations which could affect the proper functioning of the systems (e.g. regular and extraordinary maintenance work and cleaning operations of the furnace and/or of the waste gas treatment system, or severe production change)
in the case of insufficient waste gas flow or temperature which prevents the use of the system at full capacity.
9.
BAT is to limit carbon monoxide (CO) emissions from the melting furnace, when applying primary techniques or chemical reduction by fuel, for the reduction of NOX emissions
Technique | Applicability
Primary techniques for the reduction of NOX emissions are based on combustion modifications (e.g. reduction of air/fuel ratio, staged combustion low-NOX burners, etc.). Chemical reduction by fuel consists of the addition of hydrocarbon fuel to the waste gas stream to reduce the NOX formed in the furnace.
The increase in CO emissions due to the application of these techniques can be limited by a careful control of the operational parameters
Applicable to conventional air/fuel fired furnaces.
Parameter | BAT-AEL
Carbon monoxide, expressed as CO | < 100 mg/Nm3
10.
BAT is to limit ammonia (NH3) emissions, when applying selective catalytic reduction (SCR) or selective non-catalytic reduction (SNCR) techniques for a high efficiency NOX emissions reduction
Technique | Applicability
The technique consists of adopting and maintaining suitable operating conditions of the SCR or SNCR waste gas treatment systems, with the aim of limiting emissions of unreacted ammonia | Applicable to melting furnaces fitted with SCR or SNCR
[The higher levels are associated with higher inlet NOX concentrations, higher reduction rates and the ageing of the catalyst.]
Parameter | BAT-AELs
Ammonia, expressed as NH3 | < 5 – 30 mg/Nm3
11.
BAT is to reduce boron emissions from the melting furnace, when boron compounds are used in the batch formulation, by using one or a combination of the following techniques:
[A description of the techniques is given in Sections 1.10.1, 1.10.4 and 1.10.6.]
Technique | Applicability
Operation of a filtration system at a suitable temperature for enhancing the separation of boron compounds in the solid state, taking into account that some boric acid species may be present in the flue-gas as gaseous compounds at temperatures below 200 °C, but also as low as 60 °C
The applicability to existing plants may be limited by technical constraints associated with the position and characteristics of the existing filter system
Use of dry or semi-dry scrubbing in combination with a filtration system
The applicability may be limited by a decreased removal efficiency of other gaseous pollutants (SOX, HCl, HF) caused by the deposition of boron compounds on the surface of the dry alkaline reagent
Use of wet scrubbing
The applicability to existing plants may be limited by the need of a specific waste water treatment
The monitoring of boron emissions should be carried out according to a specific methodology which allows measurement of both solid and gaseous forms and to determine the effective removal of these species from the flue gases.
12.
BAT is to reduce water consumption by using one or a combination of the following techniques:
Technique | Applicability
Minimisation of spillages and leaks
The technique is generally applicable
Reuse of cooling and cleaning waters after purging
The technique is generally applicable.
Recirculation of scrubbing water is applicable to most scrubbing systems; however, periodic discharge and replacement of the scrubbing medium may be necessary
Operate a quasi-closed loop water system as far as technically and economically feasible
The applicability of this technique may be limited by the constraints associated with the safety management of the production process. In particular:
open circuit cooling may be used when safety issues require for it (e.g. incidents when large quantities of glass need to be cooled)
water used in some specific process (e.g. downstream activities in the continuous filament glass fibre sector, acid polishing in the domestic and special glass sectors, etc.) may have to be discharged in total or in part to the waste water treatment system
13.
BAT is to reduce the emission load of pollutants in the waste water discharges by using one or a combination of the following waste water treatment systems:
Technique | Applicability
Standard pollution control techniques, such as settlement, screening, skimming, neutralisation, filtration, aeration, precipitation, coagulation and flocculation, etc.
Standard good practice techniques to control emissions from storage of liquid raw materials and intermediates, such as containments, inspection/testing of tanks, overfill protection, etc.
The techniques are generally applicable