ANNEX III, Directive (EU) 2011/65

In forcesince 1 Jul 2026cited 44×

[Directive 97/68/EC of the European Parliament and of the Council of 16 December 1997 on the approximation of the laws of the Member States relating to measures against the emission of gaseous and particulate pollutants from internal combustion engines to be installed in non-road mobile machinery (OJ L 59, 27.2.1998, p. 1).] [Council Directive 69/493/EEC of 15 December 1969 on the approximation of the laws of the Member States relating to crystal glass (OJ L 326, 29.12.1969, p. 36).] [Regulation (EU) 2016/1628 of the European Parliament and of the Council of 14 September 2016 on requirements relating to gaseous and particulate pollutant emission limits and type-approval for internal combustion engines for non-road mobile machinery, amending Regulations (EU) No 1024/2012 and (EU) No 167/2013, and amending and repealing Directive 97/68/EC (OJ L 252, 16.9.2016, p. 53).] [The exemption shall not cover EEE for supply to the general public where the EEE or accessible part thereof may, during normal or foreseeable conditions of use, be placed in the mouth by children. However, the exemption shall apply where the following can be both demonstrated: the rate of lead release from such an EEE or any accessible part, whether coated or uncoated, does not exceed 0,05 μg/cm2 per hour (equivalent to 0,05 μg/g/h), for coated articles, that the coating is sufficient to ensure that this release rate is not exceeded for a period of at least two years of normal or reasonably foreseeable conditions of use of the EEE. For the purpose of this footnote, it is considered that an EEE or accessible part of an EEE may be placed in the mouth by children if it is smaller than 5 cm in one dimension or has a detachable or protruding part of that size.]

Exemption | Scope and dates of applicability

1 | Mercury in single capped (compact) fluorescent lamps not exceeding (per burner): |

1(a) | For general lighting purposes < 30 W: 2,5 mg | Expires on 24 February 2023

1(b) | For general lighting purposes ≥ 30 W and < 50 W: 3,5 mg | Expires on 24 February 2023

1(c) | For general lighting purposes ≥ 50 W and < 150 W: 5 mg | Expires on 24 February 2023

1(d) | For general lighting purposes ≥ 150 W: 15 mg | Expires on 24 February 2023

1(e) | For general lighting purposes with circular or square structural shape and tube diameter ≤ 17 mm: 5 mg | Expires on 24 February 2023

1(f) – I | For lamps designed to emit mainly light in the ultraviolet spectrum: 5 mg | Expires on 24 February 2027

1(f) – II | For special purposes: 5 mg | Expires on 24 February 2025

1(g) | For general lighting purposes < 30 W with a lifetime equal or above 20000 h: 3,5 mg | Expires on 24 August 2023

2(a) | Mercury in double-capped linear fluorescent lamps for general lighting purposes not exceeding (per lamp): |

2(a)(1) | Tri-band phosphor with normal lifetime and a tube diameter < 9 mm (e.g. T2): 4 mg | Expires on 24 February 2023

2(a)(2) | Tri-band phosphor with normal lifetime and a tube diameter ≥ 9 mm and ≤ 17 mm (e.g. T5): 3 mg | Expires on 24 August 2023

2(a)(3) | Tri-band phosphor with normal lifetime and a tube diameter > 17 mm and ≤ 28 mm (e.g. T8): 3,5 mg | Expires on 24 August 2023

2(a)(4) | Tri-band phosphor with normal lifetime and a tube diameter > 28 mm (e.g. T12): 3,5 mg | Expires on 24 February 2023

2(a)(5) | Tri-band phosphor with long lifetime (≥ 25000 h): 5 mg. | Expires on 24 February 2023

2(b) | Mercury in other fluorescent lamps not exceeding (per lamp): |

2(b)(1) | Linear halophosphate lamps with tube > 28 mm (e.g. T10 and T12): 10 mg | Expires on 13 April 2012

2(b)(2) | Non-linear halophosphate lamps (all diameters): 15 mg | Expires on 13 April 2016

2(b)(3) | Non-linear tri-band phosphor lamps with tube diameter > 17 mm (e.g. T9): 15 mg | Expires on 24 February 2023; 10 mg may be used per lamp from 25 February 2023 until 24 February 2025

2(b)(4)- I | Lamps for other general lighting and special purposes (e.g. induction lamps): 15 mg | Expires on 24 February 2025

2(b)(4)- II | Lamps emitting mainly light in the ultraviolet spectrum: 15 mg | Expires on 24 February 2027

2(b)(4)- III | Emergency lamps: 15 mg | Expires on 24 February 2027

3 | Mercury in cold cathode fluorescent lamps and external electrode fluorescent lamps (CCFL and EEFL) for special purposes used in EEE placed on the market before 24 February 2022 not exceeding (per lamp): |

3(a) | Short length (≤ 500 mm): 3,5 mg | Expires on 24 February 2025

3(b) | Medium length (> 500 mm and ≤ 1500 mm): 5 mg | Expires on 24 February 2025

3(c) | Long length (> 1500 mm): 13 mg | Expires on 24 February 2025

4(a) | Mercury in other low pressure discharge lamps (per lamp): 15 mg | Expires on 24 February 2023

4(a)-I | Mercury in low pressure non-phosphor coated discharge lamps, where the application requires the main range of the lamp-spectral output to be in the ultraviolet spectrum: up to 15 mg mercury may be used per lamp | Expires on 24 February 2027

4(b) | Mercury in High Pressure Sodium (vapour) lamps for general lighting purposes not exceeding (per burner) in lamps with improved colour rendering index Ra > 80: P ≤ 105 W: 16 mg may be used per burner | Expires on 24 February 2027

4(b)-I | Mercury in High Pressure Sodium (vapour) lamps for general lighting purposes not exceeding (per burner) in lamps with improved colour rendering index Ra > 60: P ≤ 155 W: 30 mg may be used per burner | Expires on 24 February 2023

4(b)-II | Mercury in High Pressure Sodium (vapour) lamps for general lighting purposes not exceeding (per burner) in lamps with improved colour rendering index Ra > 60: 155 W < P ≤ 405 W: 40 mg may be used per burner | Expires on 24 February 2023

4(b)-III | Mercury in High Pressure Sodium (vapour) lamps for general lighting purposes not exceeding (per burner) in lamps with improved colour rendering index Ra > 60: P > 405 W: 40 mg may be used per burner | Expires on 24 February 2023

4(c) | Mercury in other High Pressure Sodium (vapour) lamps for general lighting purposes not exceeding (per burner): |

4(c)-I | P ≤ 155 W: 20 mg | Expires on 24 February 2027

4(c)-II | 155 W < P ≤ 405 W: 25 mg | Expires on 24 February 2027

4(c)-III | P > 405 W: 25 mg | Expires on 24 February 2027

4(d) | Mercury in High Pressure Mercury (vapour) lamps (HPMV) | Expires on 13 April 2015

4(e) | Mercury in metal halide lamps (MH) | Expires on 24 February 2027

4(f) -I | Mercury in other discharge lamps for special purposes not specifically mentioned in this Annex | Expires on 24 February 2025

4(f) -II | Mercury in high pressure mercury vapour lamps used in projectors where an output ≥ 2000 lumen ANSI is required | Expires on 24 February 2027

4(f) -III | Mercury in high pressure sodium vapour lamps used for horticulture lighting | Expires on 24 February 2027

4(f) -IV | Mercury in lamps emitting light in the ultraviolet spectrum | Expires on 24 February 2027

4(g) |

Mercury in hand crafted luminous discharge tubes used for signs, decorative or architectural and specialist lighting and light-artwork, where the mercury content shall be limited as follows:

(a)

20 mg per electrode pair + 0,3 mg per tube length in cm, but not more than 80 mg, for outdoor applications and indoor applications exposed to temperatures below 20 °C;

(b)

15 mg per electrode pair + 0,24 mg per tube length in cm, but not more than 80 mg, for all other indoor applications.

Expires on 31 December 2018

5(a) | Lead in glass of cathode ray tubes |

5(b) | Lead in glass of fluorescent tubes not exceeding 0,2 % by weight |

6(a) | Lead as an alloying element in steel for machining purposes and in galvanised steel containing up to 0,35 % lead by weight | Expires on 11 december 2026

6(a)-I | Lead as an alloying element in steel for machining purposes containing up to 0,35 % lead by weight | Expires on 30 June 2027 for all categories.

6(a)-II | Lead as an alloying element in batch hot-dip galvanised steel components containing up to 0,2 % lead by weight | Expires on 30 June 2027 for all categories.

6(b) | Lead as an alloying element in aluminium containing up to 0,4 % lead by weight | Expires on 11 June 2027

6(b)-I | Lead as an alloying element in aluminium containing up to 0,4 % lead by weight, provided it stems from lead-bearing aluminium scrap recycling |

Expires on 11 december 2026 for categories 1-7, 10.

Expires on 30 June 2027 for categories 9 industrial monitoring and control instruments, and 11.

6(b)-II | Lead as an alloying element in aluminium for machining purposes with a lead content up to 0,4 % by weight |

Expires on 11 June 2027 for categories 1-7, 10.

Expires on 30 June 2027 for categories 9 industrial monitoring and control instruments and 11.

6(b)-III | Lead as an alloying element in aluminium casting alloys containing up to 0,3 % lead by weight provided it stems from lead-bearing aluminium scrap recycling | Expires on 30 June 2027 for categories 1-8, 9 other than industrial monitoring and control instruments, and 10.

6(c) | Copper alloy containing up to 4 % lead by weight | Expires on 30 June 2027.

7(a) | Lead in high melting temperature type solders (i.e. lead-based alloys containing 85 % by weight or more lead) | Applies to all categories (except applications covered by point 24 of this Annex) and expires on 30 June 2027.

7(a)-I |

Lead in high melting temperature type solders (i.e. lead-based alloys containing 85 % by weight or more lead)

for internal interconnections for attaching die, or other components along with a die in semiconductor assembly with steady state or transient/impulse currents of 0,1 A or greater or blocking voltages beyond 10 V, or die edge sizes larger than 0,3 mm × 0,3 mm

Applies to all categories (except applications covered by point 24 of this Annex) and expires on 31 December 2027.

7(a)-II |

Lead in high melting temperature type solders (i.e. lead-based alloys containing 85 % by weight or more lead)

for integral (meaning internal and external) connections of die attach in electrical and electronic components, if all the following conditions are met:

the thermal conductivity of the cured/sintered die-attach material is > 35 W/(m × K),

the electrical conductivity of the cured/sintered die-attach material is > 4,7 MS/m,

solidus melting temperature is higher than 260 °C

Applies to all categories (except applications covered by point 24 of this Annex) and expires on 31 December 2027.

7(a)-III |

Lead in high melting temperature type solders (i.e. lead-based alloys containing 85 % by weight or more lead)

in first level solder joints (internal or integral connections – meaning internal and external) for manufacturing components so that subsequent mounting of electronic components onto subassemblies (i.e. modules, sub-circuit boards, substrates, or point-to-point soldering) with a secondary solder does not reflow the first level solder. This sub-entry excludes die attach applications and hermetic sealings

Applies to all categories (except applications covered by point 24 of this Annex) and expires on 31 December 2027.

7(a)-IV |

Lead in high melting temperature type solders (i.e. lead-based alloys containing 85 % by weight or more lead)

in second level solder joints for the attachment of components to printed circuit board or lead frames:

(1)

in solder balls for the attachment of ceramic ball-grid-array (BGA);

(2)

in high temperature plastic overmouldings (> 220 °C)

Applies to all categories (except applications covered by point 24 of this Annex) and expires on 31 December 2027.

7(a)-V |

Lead in high melting temperature type solders (i.e. lead-based alloys containing 85 % by weight or more lead)

as a hermetic sealing material between:

(1)

a ceramic package or plug and a metal case;

(2)

component terminations and an internal sub-part

Applies to all categories (except applications covered by point 24 of this Annex) and expires on 31 December 2027.

7(a)-VI |

Lead in high melting temperature type solders (i.e. lead-based alloys containing 85 % by weight or more lead)

for establishing electrical connections between lamp components in incandescent reflector lamps for infrared heating, high intensity discharge lamps, or oven lamps

Applies to all categories (except applications covered by point 24 of this Annex) and expires on 31 December 2027.

7(a)-VII |

Lead in high melting temperature type solders (i.e. lead-based alloys containing 85 % by weight or more lead)

for audio transducers where the peak operating temperature exceeds 200 °C

Applies to all categories (except applications covered by point 24 of this Annex) and expires on 31 December 2027.

7(b) | Lead in solders for servers, storage and storage array systems, network infrastructure equipment for switching, signalling, transmission, and network management for telecommunications |

7(c)-I | Electrical and electronic components containing lead in a glass or ceramic other than dielectric ceramic in capacitors, e.g. piezoelectronic devices, or in a glass or ceramic matrix compound | Applies to all categories and expires on 30 June 2027.

7(c)-II | Lead in dielectric ceramic in capacitors for a rated voltage of 125 V AC or 250 V DC or higher | Applies to all categories (except applications covered by point 7(c)-I or 7(c)-IV) and expires on 31 December 2027.

7(c)-III | Lead in dielectric ceramic in capacitors for a rated voltage of less than 125 V AC or 250 V DC | Expires on 1 January 2013 and after that date may be used in spare parts for EEE placed on the market before 1 January 2013

7(c)-IV | Lead in PZT based dielectric ceramic materials for capacitors which are part of integrated circuits or discrete semiconductors |

Expires on:

21 July 2021 for categories 1-7 and 10;

21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

21 July 2023 for category 8 in vitro diagnostic medical devices;

21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

7(c)-V |

Electrical and electronic components containing lead in a glass or glass matrix compound that fulfils any of the following functions:

(1)

for protection and electrical insulation in glass beads of high-voltage diodes and glass layers for wafers;

(2)

for hermetic sealing between ceramic, metal and/or glass parts;

(3)

for bonding purposes in a process parameter window for < 500 °C combined with a viscosity of 1013,3 dPas (‘glass-transition temperature’);

(4)

for use as a resistive material such as ink, with a resistivity range from 1 ohm/square to 100 megohm/square, excluding trimmer potentiometers;

(5)

for use in chemically modified glass surfaces for microchannel plates (MCPs), channel electron multipliers (CEMs) and resistive glass products (RGPs).

Applies to all categories and expires on 31 December 2027.

7(c)-VI |

Electrical and electronic components containing lead in a ceramic that fulfils any of the following functions:

(1)

for use in piezoelectric lead zirconium titanate (PZT) ceramics;

(2)

for providing ceramics with a positive temperature coefficient (PTC).

Applies to all categories (except applications covered by points 7(c)-II, 7(c)-III and 7(c)-IV of this Annex as well as point 14 of Annex IV) and expires on 31 December 2027.

8(a) | Cadmium and its compounds in one shot pellet type thermal cut-offs | Expires on 1 January 2012 and after that date may be used in spare parts for EEE placed on the market before 1 January 2012

8(b) | Cadmium and its compounds in electrical contacts |

Applies to categories 8, 9 and 11 and expires on:

21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

21 July 2023 for category 8 in vitro diagnostic medical devices;

21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

8(b)-I |

Cadmium and its compounds in electrical contacts used in:

circuit breakers,

thermal sensing controls,

thermal motor protectors (excluding hermetic thermal motor protectors),

AC switches rated at:

6 A and more at 250 V AC and more, or

12 A and more at 125 V AC and more,

DC switches rated at 20 A and more at 18 V DC and more, and

switches for use at voltage supply frequency ≥ 200 Hz.

Applies to categories 1 to 7 and 10 and expires on 21 July 2021.

9 | Hexavalent chromium as an anticorrosion agent of the carbon steel cooling system in absorption refrigerators up to 0,75 % by weight in the cooling solution |

Applies to categories 8, 9 and 11 and expires on:

21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments,

21 July 2023 for category 8 in vitro diagnostic medical devices,

21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

9(a)-I | Up to 0,75 % hexavalent chromium by weight, used as an anticorrosion agent in the cooling solution of carbon steel cooling systems of absorption refrigerators (including minibars) designed to operate fully or partly with electrical heater, having an average utilised power input < 75 W at constant running conditions | Applies to categories 1-7 and 10 and expires on 5 March 2021.

9(a)-II |

Up to 0,75 % hexavalent chromium by weight, used as an anticorrosion agent in the cooling solution of carbon steel cooling systems of absorption refrigerators:

designed to operate fully or partly with electrical heater, having an average utilised power input ≥ 75 W at constant running conditions,

designed to fully operate with non-electrical heater.

Applies to categories 1-7 and 10 and expires on 21 July 2021.

9(a)-III | Up to 0,7 % hexavalent chromium by weight, used as an anticorrosion agent in the working fluid of the carbon steel sealed circuit of gas absorption heat pumps for space and water heating | Applies to category 1 and expires on 31 December 2026.

9(b) | Lead in bearing shells and bushes for refrigerant-containing compressors for heating, ventilation, air conditioning and refrigeration (HVACR) applications |

Applies to categories 8, 9 and 11; expires on:

21 July 2023 for category 8 in vitro diagnostic medical devices,

21 July 2024 for category 9 industrial monitoring and control instruments and for category 11,

21 July 2021 for other subcategories of categories 8 and 9.

9(b)-(I) | Lead in bearing shells and bushes for refrigerant-containing hermetic scroll compressors with a stated electrical power input equal or below 9 kW for heating, ventilation, air conditioning and refrigeration (HVACR) applications | Applies to category 1; expires on 21 July 2019.

11(a) | Lead used in C-press compliant pin connector systems | May be used in spare parts for EEE placed on the market before 24 September 2010

11(b) | Lead used in other than C-press compliant pin connector systems | Expires on 1 January 2013 and after that date may be used in spare parts for EEE placed on the market before 1 January 2013

12 | Lead as a coating material for the thermal conduction module C-ring | May be used in spare parts for EEE placed on the market before 24 September 2010

13(a) | Lead in white glasses used for optical applications |

Applies to all categories; expires on:

21 July 2023 for category 8 in vitro diagnostic medical devices;

21 July 2024 for category 9 industrial monitoring and control instruments and for category 11;

21 July 2021 for all other categories and subcategories

13(b) | Cadmium and lead in filter glasses and glasses used for reflectance standards |

Applies to categories 8, 9 and 11; expires on:

21 July 2023 for category 8 in vitro diagnostic medical devices;

21 July 2024 for category 9 industrial monitoring and control instruments and for category 11;

21 July 2021 for other subcategories of categories 8 and 9

13(b)-(I) | Lead in ion coloured optical filter glass types | Applies to categories 1 to 7 and 10; expires on 21 July 2021 for categories 1 to 7 and 10

13(b)-(II) | Cadmium in striking optical filter glass types; excluding applications falling under point 39 of this Annex

13(b)-(III) | Cadmium and lead in glazes used for reflectance standards

14 | Lead in solders consisting of more than two elements for the connection between the pins and the package of microprocessors with a lead content of more than 80 % and less than 85 % by weight | Expired on 1 January 2011 and after that date may be used in spare parts for EEE placed on the market before 1 January 2011

15 | Lead in solders to complete a viable electrical connection between semiconductor die and carrier within integrated circuit flip chip packages |

Applies to categories 8, 9 and 11 and expires on:

21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

21 July 2023 for category 8 in vitro diagnostic medical devices;

21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

15(a) |

Lead in solders to complete a viable electrical connection between the semiconductor die and carrier within integrated circuit flip chip packages where at least one of the following criteria applies:

a semiconductor technology node of 90 nm or larger;

a single die of 300 mm2 or larger in any semiconductor technology node;

stacked die packages with die of 300 mm2 or larger, or silicon interposers of 300 mm2 or larger.

Applies to categories 1 to 7 and 10 and expires on 21 July 2021.

16 | Lead in linear incandescent lamps with silicate coated tubes | Expires on 1 September 2013

17 | Lead halide as radiant agent in high intensity discharge (HID) lamps used for professional reprography applications |

18(a) | Lead as activator in the fluorescent powder (1 % lead by weight or less) of discharge lamps when used as speciality lamps for diazoprinting reprography, lithography, insect traps, photochemical and curing processes containing phosphors such as SMS ((Sr,Ba)2MgSi2O7:Pb) | Expired on 1 January 2011

18(b) | Lead as activator in the fluorescent powder (1 % lead by weight or less) of discharge lamps when used as sun tanning lamps containing phosphors such as BSP (BaSi2O5:Pb) |

Expires on:

21 July 2021 for categories 1-7 and 10;

21 July 2021 for categories 8 and 9 other than in vitro diagnostic medical devices and industrial monitoring and control instruments;

21 July 2023 for category 8 in vitro diagnostic medical devices;

21 July 2024 for category 9 industrial monitoring and control instruments, and for category 11.

18(b)-I | Lead as activator in the fluorescent powder (1 % lead by weight or less) of discharge lamps containing phosphors such as BSP (BaSi2O5:Pb) when used in medical phototherapy equipment | Applies to categories 5 and 8, excluding applications covered by entry 34 of Annex IV, and expires on 21 July 2021.

This article is long: the rest is at the official publication.