4 Appendix B, Decision_act (EU) 2009/489

In forcesince 16 Jun 2009

I.

Desktop, Integrated Desktop, Notebook Computers: Below is a sample TEC calculation intended to show how compliance levels are determined based on functional adders and operational mode measurements, for an example ETEC evaluation for a Category A Notebook Computer (integrated GPU, 8 GB Memory Installed, 1 HDD)

1.

Measure values using the Appendix A test procedure:

Off = 1 W,

Sleep = 1,7 W,

Idle = 10 W,

2.

Determine which Capability Adjustments apply:

Integrated Graphics? Does not apply for Premium Graphics,

8 GB Memory installed. Does meet memory adjustment level: 8 yields a 1,6 kWh adjustment (4 · 0, 4 kWh),

3.

Apply Weightings based on Table 2 to calculate TEC:

Table 2 (for conventional notebook):

(in %)

Toff | 60

Tsleep | 10

Tidle | 30

ETEC = (8760/1000) · (Poff · Toff + Psleep · Tsleep + Pidle · Tidle),

= (8760/1000) · (Poff · 0,60 + Psleep · 0,10 + Pidle · 0,30),

= (8760/1000) · (1 · 0,60 + 1,7 · 0,10 + 10 · 0,30),

= 33,03 kWh,

4.

Determine TEC Requirement for the computer by adding any capability adjustments (step 2) to the Base TEC requirement (Table 1).

Table 1 (for notebooks):

(in kWh)

Notebook Computers

Category A | 40

Category B | 53

Category C | 88,5

ENERGY STAR TEC Requirement = 40 kWh + 1,6 kWh = 41,6 kWh,

5.

Compare ETEC to the ENERGY STAR TEC Requirement (step 4) to ascertain whether the model qualifies.

Category A TEC requirement: 41,6 kWh,

ETEC: 33,03 kWh,

33,03 kWh < 41,6 kWh,

Notebook meets the ENERGY STAR requirements.

II.

Workstations: Below is a sample PTEC calculation for a Workstation with two hard drives.

1.

Measure values using the Appendix A test procedure.

Off = 2 W,

Sleep = 4 W,

Idle = 80 W,

Max Power = 180 W,

2.

Note number of Hard Drives installed.

Two hard drives installed during test,

3.

Apply Weightings based on Table 4 to calculate PTEC:

Table 4:

(in %)

Toff | 35

Tsleep | 10

Tidle | 55

PTEC = (0,35 · Poff + 0,10 · Psleep + 0,55 · Pidle),

= (0,35 · 2 + 0,10 · 4 + 0,55 · 80),

= 45,10 W,

4.

Calculate the PTEC requirement using the formula in Table 3.

PTEC = 0,28 · [Pmax + (# HDD · 5)],

PTEC = 0,28 · [180 + (2 · 5)],

PTEC = 53,2,

5.

Compare the adjusted PTEC to the ENERGY STAR levels to determine if the model qualifies.

45,10 < 53,2,

Workstation meets the ENERGY STAR requirements.