Directive 97/23/EC requires in point 3.1.5 of Annex I (traceability) the application of suitable procedures in order to identify, by suitable means, the material making up of the components which contribute to the pressure resistance of the equipment, from their receipt and production, up to the final test of the manufactured pressure equipment. The objective of this requirement is to avoid any doubt about the material specifications used for the equipment. Manufacturers may apply different procedures, according to the characteristics and methods of manufacture. The notified body that performs the conformity assessment procedure of the equipment must assess, on a case by case basis, whether these procedures meet the requirement of point 3.1.5 of Annex I to the Directive. However, although Section 7.3.1 should be improved, it would not be proportionate not to publish the reference numbers of the standard on this ground.