To describe the precision of the method the repeatability standard deviation as defined in ISO 5725-1 [ISO5725-1: Accuracy (trueness and precision) of measurement methods and results — Part 1: General principles and definitions. 1994: Geneva.] is required. It should be estimated using data from a single-laboratory validation exercise giving Si as described in the Harmonized Guidelines for Single-Laboratory Validation of Methods of Analysis [Thompson, M., S.L.R. Ellison, and R. Wood, Harmonized Guidelines for Single-Laboratory Validation of Methods of Analysis. Pure and Applied Chemistry, 2002. 74(5): pp. 835-855.] or a collaborative trial giving Sr and SR as described in the Protocol for the design, conduct and interpretation of method-performance studies [Horwitz, W., Protocol for the design, conduct and interpretation of method-performance studies. Pure and Applied Chemistry, 1995. 67(2): pp. 331-343.].
Recital 9, Commission Regulation (EC) No 627/2006 of 21 April 2006 implementing Regulation (EC) No…
In forcesince 21 Apr 2006