Art. 4 Commission Recommendation of 27 May 2005 concerning authentication of euro coins and han…

The tests for controlling the sorting machines

In force

The control of the functioning of sorting machines should be carried out by means of a detection test, preceded, if applicable, by a check for sorting, as follows:

1.

The purpose of the sorting test is to check that the machine is capable of correctly sorting all the euro coin denominations. This is applicable in the absence of national rules governing the sorting capacity.

The sorting test requires at least one hundred genuine euro coins of each of the denominations to be tested. These coins of all denominations are mixed together and passed through the machine three times.

The acceptance ratio should be at least 98 % in each of the trials. In cases where the genuine euro coins used for the sorting and detection tests are at the border of euro specified tolerance ranges, a lower acceptance ratio may be considered.

Any genuine coins rejected by a machine should be re-tested. After three consecutive trials, all genuine coins should be accepted.

2.

The purpose of the detection test is to check that the machine is capable of rejecting euro coin-like objects that are not in conformity with the specifications of the euro coins, in particular counterfeit coins.

The detection test requires samples of counterfeit coins for all denominations concerned, with a definition also covering materials used for producing coin-like objects and non-euro coins. For that purpose, a number of representative families should be used, coming from the stocks deposited with the Coin National Analysis Centres (CNACs) or the European Technical and Scientific Centre (ETSC). The ETSC, in collaboration with the CNACs defines and updates these families.

These counterfeits are mixed with an appropriate number of genuine coins, defined in collaboration with the ETSC and passed through the machine three times. All counterfeits should be rejected on each of the trials.

3.

In the respect of national rules, the tests provided for in this Article should be performed at least once a year on each of the sorting machines at the sites where the authentication takes place, at the establishments selected in line with Article 3.