Lead and its inorganic compounds
1.1. Biological monitoring must include measuring the blood lead level (PbB) using absorption spectrometry or a method giving equivalent results.
1.1.1. Until 31 December 2028, the binding biological limit value is:
30 μg Pb/100 ml blood
For workers whose blood lead level exceeds the biological limit value of 30 μg Pb/100 ml blood due to exposure which has occurred before 9 April 2026, but is below 70 μg Pb/100 ml blood, medical surveillance is carried out on a regular basis. If a declining trend towards the limit value of 30 μg Pb/100 ml blood is established in those workers, they may be allowed to continue with work involving exposure to lead.
1.1.2. From 1 January 2029, the binding biological limit value is:
15 μg Pb/100 ml blood [It is recommended that the blood lead level in women of childbearing age does not exceed the reference values of the general population not occupationally exposed to lead in the respective EU Member State. When national reference levels are not available, it is recommended that blood lead levels in women of childbearing age do not exceed the Biological Guidance Value of 4,5 μg/100 ml.]
For workers whose blood lead level exceeds the biological limit value of 15 μg Pb/100 ml blood due to exposure which has occurred before 9 April 2026, but is below 30 μg Pb/100 ml blood, medical surveillance is carried out on a regular basis. If a declining trend towards the limit value of 15 μg Pb/100 ml blood is established in those workers, they may be allowed to continue with work involving exposure to lead.
1.2. Medical surveillance is carried out if exposure to a concentration of lead in air is greater than 0,015 mg/m3, calculated as a time-weighted average over 40 hours per week, or a blood lead level greater than 9 μg Pb/100 ml blood is measured in individual workers. Medical surveillance is also carried out with regard to female workers of childbearing age whose blood lead level exceeds 4,5 μg Pb/100 ml blood or the national reference value of the general population not occupationally exposed to lead, if such a value exists.