Add following new Regulations:
Such decks shall be fitted with an efficient drainage system having an appropriate drainage capacity to dispose of washing water and fish guts.
All openings necessary for fishing operations shall be provided with means for quick and efficient closure by one person.
Where the catch is brought on to such decks for handling or processing, the catch shall be placed in a pound. Such pounds shall comply with Regulation 11 of Chapter III. An efficient drainage system shall be fitted. Adequate protection against inadvertent influx of water to the working deck shall be provided.
At least two exits from such decks shall be provided.
The clear headroom in the working space shall at all points be not less than two metres.
A fixed ventilation system providing at least six changes of air per hour shall be provided.
All ships shall be provided with draught marks in decimetres on the stem and the stern on both sides.
Such marks shall be placed as close as practicable to the perpendiculars.
If RSW- or CSW-tanks or similar tank systems are used, such tanks shall be provided with a separate, permanently fitted arrangement for the filling and emptying of seawater.
If such tanks are to be used also for carrying dry cargo, the tanks shall be arranged with a bilge system and provided with adequate means to avoid ingress of water from the bilge system into the tanks.’
Add following new paragraph 4:
‘4. The inclining test and determination of conditions required by Regulation III/9(1) shall be performed at least every 10 years.’
Add following text to paragraph 10: ‘If this power source is electrical, the emergency source of electrical power shall be capable of serving the auxiliary means for activating the rudder for a period of at least 10 minutes.’
Add following paragraph 3:
‘3. Navigation lights, if solely electrical, shall be supplied through their own separate switchboard and adequate means for the monitoring of such lights shall be provided.’
Notwithstanding paragraph 2, for vessels of a length of 45 metres and over, the emergency source of electrical power shall be capable of serving the installations listed in that Regulation for a period of not less than eight hours.
Notwithstanding the provisions of this Regulation, all machinery spaces of category A shall be fitted with a fixed fire-extinguishing arrangement.
Notwithstanding the provisions of this Regulation, all machinery spaces of category A shall be fitted with a fixed fire-extinguishing arrangement.