Systems of attestation of conformity
For the product(s) and intended use(s) listed below, CEN/Cenelec are requested to specify the following system(s) of attestation of conformity in the relevant harmonized standard(s):
Product(s) | Intended use(s) | Level(s) or class(es) | Attestation of conformity system(s)
Masonry units category I (1) | in walls, columns and partitions | — | 2+
Factory-made, designed masonry mortars (2)
Masonry units category II | in walls, columns and partitions | — | 4
Factory-made, prescribed, masonry mortars (3)
Factory-made rendering/plastering mortars | in wall, column, partition and ceiling finishes
Units with a specified mean compressive strength with a probability of failure to reach it not exceeding 5 %.
Mortars designed and manufactured to achieve specific performance requirements.
Mortars manufactured from specific proportion of constituents which may be assumed to achieve associated performance requirements.
System 2+: See Annex III (2) (ii) to Directive 89/106/EEC, first possibility, including certification of the factory production control by an approved body.
System 4: See Annex III (2) (ii) to Directive 89/106/EEC, third possibility.
The specification for the system should be such that it can be implemented even where performance does not need to be determined for a certain characteristic, because at least one Member State has no legal requirement at all for such characteristic (see Article 2 (1) of Directive 89/106/EEC and, where applicable, clause 1.2.3 of the interpretative documents). In those cases the verification of such a characteristic must not be imposed on the manufacturer if he does not wish to declare the performance of the product in that respect.
PRODUCT FAMILY
MASONRY AND RELATED PRODUCTS (2/3)
Systems of attestation of conformity
For the product(s) and intended use(s) listed below, CEN/Cenelec are requested to specify the following system(s) of attestation of conformity in the relevant harmonized standard(s):
Product(s) | Intended use(s) | Level(s) or class(es) | Attestation of conformity system(s)
Ties, tension straps, joist hangers, brackets, support angles, bed joint reinforcement and lintels | in walls and partitions | — | 3
System 3: See Annex III 2 (ii) Directive 89/106/EEC, second possibility.
The specification for the system should be such that it can be implemented even where performance does not need to be determined for a certain characteristic, because at least one Member State has no legal requirement at all for such characteristic (see Article 2 (1) of Directive 89/106/EEC and, where applicable, clause 1.2.3 of the interpretative documents). In those cases the verification of such a characteristic must not be imposed on the manufacturer if he does not wish to declare the performance of the product in that respect.
PRODUCT FAMILY
MANSONRY AND RELATED PRODUCTS (3/3)
Systems of attestation of conformity
For the product(s) and intended use(s) listed below, CEN/Cenelec are requested to specify the following system(s) of attestation of conformity in the relevant harmonized standard(s)
Product(s) | Intended use(s) | Level(s) or class(es)
(Reaction to fire) (1) | Attestation of conformity system(s)
Masonry units incorporating thermal insulating materials placed on a face susceptible to be exposed to fire | in walls and partitions subject to reaction to fire regulations | A1 (2), A2 (2), B (2), C (2) | 1
A1 (3), A2 (3), B (3), C (3), D, E | 3
(A1 to E) (4), F | 4
For reaction to fire, see Commission Decision 2000/147/EC (OJ L 50, 23.2.2000, p. 14).
Products/materials for which a clearly identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of organic material) .
Products/materials not covered by footnote 2 .
Products/materials that do not require to be tested for reaction to fire (e.g. Products/materials of Classes A1 according to Commission Decision 96/603/EC).
System 1: See Annex III (2) (i) to Directive 89/106/EEC, without audit-testing of samples.
System 3: See Annex III (2) (ii) to Directive 89/106/EEC, second possibility.
System 4: See Annex III (2) (ii) to Directive 89/106/EEC, third possibility.
The specification for the system should be such that it can be implemented even where performance does not need to be determined for a certain characteristic, because at least one Member State has no legal requirement at all for such characteristic (see Article 2 (1) of Directive 89/106/EEC and, where applicable, clause 1.2.3 of the interpretative documents). In those cases the verification of such a characteristic must not be imposed on the manufacturer if he does not wish to declare the performance of the product in that respect.
( 1 ) OJ L 40, 11. 2. 1989, p. 12.
( 2 ) OJ L 220, 30. 8. 1993, p. 1.
( 3 ) Products/materials for which a cleary identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of organic material).
( 4 ) Products/materials for which a cleary identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of organic material).
( 5 ) Products/materials for which a cleary identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of organic material).
( 6 ) Products/materials for which a cleary identifiable stage in the production process results in an improvement of the reaction to fire classification (e.g. an addition of fire retardants or a limiting of organic material).