1.1. Unsweetened condensed high fat milk
Unsweetened condensed milk
Unsweetened condensed partly skimmed milk
Unsweetened condensed skimmed milk
Shake and invert the closed can. Open the can and slowly pour the milk into a second container which can be closed hermetically, mixing by repeated transfer. Ensure that all remaining fat and milk adhering to the wall and the ends of the can are mixed in with the sample. Close the container. If the contents are not homogeneous warm the container in a waterbath at 40 oC. Shake vigorously every 15 minutes. After two hours, remove the container from the water-bath and let it cool to room temperature. Remove the lid and thoroughly mix the contents of the container with a spoon or spatula (if the fat has separated the sample should not be tested). Store in a cool place.
1.2. Sweetened condensed milk
Sweetened condensed partly skimmed milk
Sweetened condensed skimmed milk
Cans: Warm the closed can in a waterbath at 30 to 40 oC for about 30 minutes. Open the can and thoroughly mix the contents with a spatula or a spoon by making upward, downward, and circular movements in order to obtain an intimate mixture of the top and bottom layers with all the contents. Ensure that the remaining milk adhering to the wall and end of the can is incorporated in the sample. As far as possible, pour the contents into a second container provided with an air-tight lid. Close the container and store in a cool place.
Tubes: Cut the end and pour the contents into a container provided with an air-tight lid. Next, cut the tube lengthwise. Scrape out all material adhering to the interior and mix it carefully with the rest of the contents. Store the container in a cool place.
1.3. Dried high fat milk or high fat milk powder
Dried whole milk or whole milk powder
Dried partly skimmed milk or partly skimmed-milk powder
Dried skimmed milk or skimmed-milk powder
Transfer the milk powder to a clean, dry container (with air-tight lid) of a capacity of twice the volume of the powder. Close the container immediately and thoroughly mix the milk powder by repeatedly shaking and inverting the container. During the preparation of the sample exposure of the milk powder to the atmosphere should be avoided as far as possible to minimize absorption of moisture.
2.1.1. Wherever mention is made of water for dissolution, dilution or washing purposes, distilled water, or demineralized water of at least equivalent purity shall be used.
2.1.2. Wherever reference is made to ‘dissolution’, ‘solution’ or ‘dilution’ without further indication, ‘dissolution in water’, ‘solution in water’ and ‘dilution in water’ is meant.
All chemicals used shall be of recognized analytical reagent quality except where otherwise specified.
The lists of equipment contain only those items with a specialized use and items with a particular specification.
Analytical balance means a balance capable of weighing to at least 0,1 mg.
Except where otherwise specified, the results shall be calculated as a percentage by mass of the sample as received by the laboratory.
The result shall not contain more significant figures than are justified by the precision of the method of analysis used.
The test report shall identify the method of analysis used as well as the results obtained. In addition, it shall mention all details of procedure not specified in the method of analysis, or which are optional, as well as any circumstances that may have influenced the results obtained.
The test report shall give all the information necessary for the complete identification of the sample.
This method determines the dry matter content of:
unsweetened condensed high fat milk,
unsweetened condensed milk,
unsweetened condensed partly skimmed milk,
unsweetened condensed skimmed milk,
sweetened condensed milk,
sweetened condensed partly skimmed milk,
sweetened condensed skimmed milk.
The dry matter content of condensed milks: dry matter content as determined by the method specified.
A known amount of the sample is diluted with water, mixed with sand and dried at a temperature of 99 oC ± 1 oC. The mass after drying is the mass of dry matter and is calculated as a percentage by mass of the sample.
Quartz sand or sea sand, treated with hydrochloric acid (size of the grains: 0,18 to 0,5 mm, that is passing through a 500 micron sieve and retained by a 180 micron sieve). It should meet the following control test:
Heat about 25 g of sand for two hours in the drying oven (5.3) as described in 6.1. to 6.3. Add 5 ml of water, heat again in the oven for two hours, cool and reweigh. The difference between the two masses should not exceed 0,5 mg.
If necessary treat the sand with a 25 % hydrochloric acid solution for three days, mixing occasionally. Wash with water until the acid reaction disappears or the wash water is chloride free. Dry at 160 oC and re-test as above.
5.1. Analytical balance.
5.2. Metal dishes, preferably of nickel, aluminium or stainless steel. The dishes must have lids which fit very well but which are readily removed. Suitable dimensions are: diameter 60 to 80 mm and depth about 25 mm.
5.3. Atmospheric-pressure drying oven, well ventilated, thermostatically controlled with temperature regulated at 99 oC ± 1 oC. The temperature should be uniform throughout the oven.
5.4. Desiccator, containing freshly activated silica gel with a water content indicator or an equivalent desiccant.
5.5. Glass rods, flattened at one end of such a length that they can fit inside the metal dishes (5.2).
5.6. Waterbath, boiling.
6.1. Place about 25 g sand (4) and a short glass rod (5.5) in the dish (5.2).
6.2. Without covering the dish and contents with the lid, place the dish, contents and lid in the oven (5.3) and heat for two hours.
6.3. Replace lid and transfer the dish to the desiccator (5.4). Allow to cool to room temperature and accurately weigh to the nearest 0,1 mg (M0).
6.4. Tilt the sand to one side of the dish. Introduce into the clear space about 1,5 g of the sample of sweetened condensed milk and 3,0 g of unsweetened condensed milk. Replace the lid and accurately weigh to the nearest 0,1 mg (M1).
6.5. Remove the lid, add 5 ml of water and, with the aid of the glass rod, mix the liquids and then the sand and the liquid portion. Leave the rod in the mixture.
6.6. Place the dish on a boiling waterbath (5.6) until the water has evaporated; this usually takes 20 minutes. Stir the mixture from time to time with the rod to keep the mass well aerated so that the mass when dry does not form a cake. Lay the rod inside the dish.
6.7. Place the dish and lid in the oven for one and a half hours.
6.8. Replace the lid, transfer the dish to the desiccator (5.4), allow to cool to room temperature and accurately weigh to the nearest 0,1 mg.
6.9. Replace the dish and lid in the oven, uncover the dish and heat it with its lid for a further hour.
6.10. Repeat process 6.8.
6.11. Repeat the described processes 6.9 and 6.10 until the difference in mass of two successive weighings is less than 0.5 mg or until the mass increases. If an increase in mass occurs use the lowest mass obtained in the calculation (7.1). Let the final weight recorded be M2 g.
The content of dry matter, calculated as a percentage by mass of the sample, is given by:
M2 - M0M1 - M0×100
where:
M0mass, in g of the dish, lid and sand after process 6.3;
M1mass, in g of the dish, lid, sand and sample after process 6.4;
M2mass, in g of the dish, lid, sand and dried sample after process 6.11.
The difference between the results of two determinations carried out simultaneously or in rapid succession on the same sample, by the same analyst, under the same conditions, shall not exceed 0,2 g of dry matter per 100 g of the product.
8.1. The total milk solids content of the sweetened condensed milk is given by:
Total dry matter (obtained by method 1, Annex II) — sucrose (obtained by method 5, Annex II).
8.2. The milk solids not fat content of the sweetened condensed milks is given by:
Total dry matter (obtained by method 1, Annex II) — (sucrose content obtained by method 5, Annex II) and fat content (obtained by method 3, Annex II).
8.3. The milk solids not fat content of unsweetened condensed milks is given by:
Total dry matter (obtained by method 1, Annex II) — fat content (obtained by method 3, Annex II).
This method determines the loss of mass on drying of:
dried high fat milk or high fat milk powder,
dried whole milk or whole milk powder,
dried partly skimmed milk or partly skimmed-milk powder,
dried skimmed milk or skimmed-milk powder.
Moisture content: the loss of mass on drying as determined by the method specified.
The residual mass of a test portion is determined after drying at atmospheric pressure in an oven at 102 oC ± 1 oC to constant mass. The loss of mass is calculated as a percentage by mass of the sample.
4.1. Analytical balance.
4.2. Dishes, preferably of nickel, aluminium, stainless steel or glass. The dishes must have lids which fit very well but which can readily be removed. Suitable dimensions are: diameter 60 to 80 mm and depth about 25 mm.
4.3. Atmospheric-pressure drying oven, well ventilated, thermostatically controlled with temperature regulation (at 102 oC ± 1 oC). The temperature should be uniform throughout the oven.
4.4. Desiccator, containing freshly activated silica gel with a water content indicator or an equivalent desiccant.
5.1. Uncover the dish (4.2) and place it and its lid in the oven (4.3) and heat for about one hour.
5.2. Place the lid on the dish and transfer the covered dish to the desiccator (4.4). Allow it to cool to room temperature and accurately weigh to the nearest 0,1 mg (Mo).
5.3. Introduce approximately 2 g of dried milk sample into the dish, cover the dish with the lid and accurately weigh to the nearest 0,1 mg the covered dish as quickly as possible (M1).
5.4. Uncover the dish and put it with its lid in the oven for two hours.
5.5. Replace the lid, transfer the covered dish to the desiccator, allow it to cool to room temperature and accurately weigh to the nearest 0,1 mg as quickly as possible.
5.6. Uncover the dish and heat it and its lid for one hour in the oven.
5.7. Repeat process 5.5.
5.8. Repeat processes 5.6 and 5.5 until the decrease in mass between the successive weighings does not exceed 0,5 mg or until the mass increases. If an increase in mass occurs use the lowest mass obtained in the calculation (6.1). Let the final weight recorded be M2 g.
Calculate the loss of mass on drying of the sample, expressed as a percentage by mass, by the formula:
M1 - M2M1 - M0×100
where:
M0mass, in g of the dish and its lid after process 5.2;
M1mass, in g of the dish, its lid and sample after process 5.3;
M2mass, in g of the dish, its lid and final sample after process 5.5.
The difference in results between two determinations carried out simultaneously or in rapid succession on the same sample, by the same analyst, under the same conditions, shall not exceed 0,1 g of moisture per 100 g of product.
This method determines the fat content of:
unsweetened condensed high fat milk,
unsweetened condensed milk,
unsweetened condensed partly skimmed milk,
unsweetened condensed skimmed milk,
sweetened condensed milk,
sweetened condensed partly skimmed milk,
sweetened condensed skimmed milk.
The fat content of condensed milks: fat content as determined by the method specified.
The fat content is determined by extraction of the fat from an ammoniacal alcoholic solution of the sample with diethyl ether and light petroleum followed by evaporation of the solvents and weighing of the residue and calculation as a percentage by mass of the sample, according to the principle of Rose-Gottlieb.
All reagents should conform to the requirements specified in the blank test (6.1). If necessary, reagents may be redistilled in the presence of about 1 g of butterfat for 100 ml of solvent.
4.1. Ammonia solution, approximately 25 % (m/m) NH3 (density at 20 oC approximately 0.91 g/ml), or a stronger solution of known concentration.
4.2. Ethanol, 96 ± 2 % (v/v) or, if not available, ethanol denatured with methanol, ethyl methyl ketone or light petroleum.
4.3. Diethyl ether, peroxide-free.
Note 1:
To test for peroxides, add to 10 ml of the ether in a small glass stoppered cylinder, previously rinsed with the ether, 1 ml freshly prepared 10 % potassium iodide solution. Shake and let stand for one minute. No yellow colour should be observed in either layer.
Note 2:
Diethyl ether may be maintained free from peroxides by adding wet zinc foil that has been completely immersed in dilute acidified copper sulphate solution for one minute and subsequently washed with water. Use per litre approximately 8000 mm2 zinc foil; cut in strips long enough to reach at least halfway up the container.
4.4. Light petroleum (petroleum ether), with any boiling range between 30 and 60 oC.
4.5. Mixed solvent, prepared shortly before use by mixing equal volume of diethyl ether (4.3) and light petroleum (4.4) (where the use of mixed solvent is indicated, it may be replaced by either diethyl ether or light petroleum alone).
5.1. Analytical balance.
5.2. Suitable extraction tubes or flasks, provided with ground glass stoppers or other closures un-. affected by the solvents used.
5.3. Flasks, thin-walled and flat-bottomed, 150 to 250 ml capacity.
5.4. Atmospheric pressure drying oven, well ventilated and thermostatically controlled (adjusted to operate at 102 oC ± 1 oC.
5.5. Anti-bumping granules, fat-free, non porous, non friable in use, e.g. glass beads or pieces of silicon carbide (the use of this material is optional; see clause 6.2.1.
5.6. Siphon, to fit extraction tubes.
5.7. Centrifuge (optional).
At the same time as the determination of the fat content of the sample, carry out a blank determination on 10 ml of water using the same type of extraction apparatus, the same reagents in the same amounts and the same procedure as described hereafter, excluding clause 6.2.2. If the blank exceeds 0.5 mg, the reagents should be checked and the impure reagent or reagents should be purified or replaced.
6.2.1. Dry a flask (5.3) (together with, if required, some anti-bumping granules (5.5) to promote gentle boiling during the subsequent removal of the solvents) in the oven (5.4) for half to one hour. Allow the flask to cool to the temperature of the balance room and accurately weigh the cooled flask to the nearest 0,1 mg.
6.2.2. Stir the prepared sample and immediately weigh, to the nearest 1 mg, 2 to 2,5 g of the sample if sweetened or 4 to 5 g of the sample if unsweetened directly in, or by difference into, the extraction apparatus (5.2). Add water to 10,5 ml and shake gently with slight warming (40 to 50 oC) until the product is completely dispersed. The sample must be dispersed completely otherwise the determination should be repeated.
6.2.3. Add 1,5 ml ammonia (25 %) (4.1) or a corresponding volume of a stronger solution, and mix well.
6.2.4. Add 10 ml ethanol (4.2) and mix the liquids gently but thoroughly in the unclosed apparatus.
6.2.5. Add 25 ml diethyl ether (4.3). Cool under running water. Close the apparatus and shake vigorously and invert repeatedly for one minute.
6.2.6. Remove the stopper carefully and add 25 ml light petroleum (4.4) using the first few millilitres to rinse the stopper and inside of the neck of the apparatus, allowing the rinsings to run into the apparatus. Close by replacing the stopper and shake and invert repeatedly for 30 seconds. Do not shake too vigorously if centrifuging is not to be used in 6.2.7.
6.2.7. Allow the apparatus to stand until the upper liquid layer has become clear and has distinctly separated from the lower aqueous layer. Alternatively carry out the separation using a suitable centrifuge (5.7).
Note:
When a centrifuge which is not driven by a three-phase motor, is used, sparks may occur and care must therefore be taken to avoid an explosion or fire from any ether vapours, coming, for example, from a broken tube.
6.2.8. Remove the stopper, rinse it and the inside of the neck of the apparatus with a few millilitres of mixed solvent (4.5) and allow the rinsings to run into the apparatus. Carefully transfer as much as possible of the supernatant layer by decantation or by means of a siphon (5.6) into the pre pared flask (6.2.1).
Note:
If the transfer is not made using a siphon, it may be necessary to add a little water in order to raise the interface between the two layers thus aiding decantation.
6.2.9. Rinse the outside and the inside of the neck of the apparatus or the tip and the lower part of the siphon with a few millilitres of mixed solvent (4.5). Allow the rinsings from the outside of the apparatus to run into the flask and the rinsings from the inside of the neck and from the siphon to run into the extraction apparatus.
6.2.10. Make a second extraction by repeating the procedure of 6.2.5 to 6.2.9 inclusive but using only 15 ml diethyl ether and 15 ml light petroleum.
6.2.11. Make a third extraction by repeating the procedure of 6.2.10 but omit the final rinsing (6.2.9).
Note:
It is not mandatory to carry out this third extraction when analysing skimmed unsweetened condensed milk and skimmed sweetened condensed milk samples.
6.2.12. Carefully evaporate or distil off as much solvent (including the ethanol) as possible. If the flask is of small capacity, it will be necessary to remove some of the solvent as above after each extraction.
6.2.13. When there is no appreciable odour of solvent place the flask on its side in the oven and heat for one hour.
6.2.14. Remove the flask from the oven, allow to cool to the temperature of the balance room and accurately weigh to the nearest 0,1 mg.
6.2.15. Repeat 6.2.13 and 6.2.14 for heating periods of 30 to 60 minutes until the difference in mass of two successive weighings is less than 0.5 mg or until the mass increases. If an increase in mass occurs use the lowest mass obtained in the calculation (7.1). Let the final weight recorded be M1 g.
6.2.16. Add 15 to 25 ml light petroleum in order to confirm that the extracted matter is wholly soluble. Warm gently and swirl the solvent until all the fat is dissolved.
6.2.16.1. If the extracted matter is wholly soluble in the light petroleum, the mass of fat is the difference between the weights determined at stages 6.2.1 and 6.2.15.
6.2.16.2. If any insoluble matter is present, or in case of doubt, completely extract the fat from the flasks by repeated washing with warm light petroleum, allowing the undissolved material to settle before each decantation. Rinse the outside of the neck of the flask three times. Heat the flask, placed on its side, for one hour in the oven, allow to cool to the temperature of the balance room as before (6.2.1) and weigh to the nearest 0,1 mg. The mass of fat is the difference between the mass obtained at 6.2.15 and this final mass.
The mass, in g of fat extracted is:
(M1 — M2) — (B1 — B2)
and the fat content of the sample, expressed as a percentage is:
M1 - M2- B1 - B2S×100
where:
M1mass, in g of flask M with fat after stage 6.2.15;
M2mass, in g of flask M after stage 6.2.1 or, in the case of undissolved material or doubt, stage 6.2.16.2;
B1mass, in g of flask B of the blank after stage 6.2.15;
B2mass, in g of flask B after stage 6.2.1 or, in the case of undissolved material or doubt, stage 6.2.16.2;
Smass, in g of sample used.
The difference between results of two determinations carried out obtained simultaneously or in rapid succession on the same sample, by the same analyst, under the same conditions, shall not exceed 0,05 g fat per 100 g of the product.
This method determines the fat content of:
dried high fat milk or high fat milk powder,
dried whole milk or whole milk powder,
dried partly skimmed milk or partly skimmed-milk powder,
dried skimmed milk or skimmed-milk powder.
The fat content of dried milks: fat content as determined by the method specified.
The fat content is determined by extraction of the fat from an ammoniacal alcoholic solution of sample with diethyl ether and light petroleum, followed by evaporation of the solvents and weighing of the residue and calculation as a percentage by mass of the sample, according to the principle of Rose-Gottlieb.
All reagents should conform to the requirements specified in the blank test (6.1). If necessary, reagents may be redistilled in the presence of about 1 g of butterfat per 100 ml of solvent.
4.1. Ammonia solution, approximately 25 % (m/m) NH3 (density at 20 oC approximately 0.91 g/ml), or stronger solution of known concentration.
4.2. Ethanol, 96 ± 2 % (v/v) or, if not available, ethanol denatured with methanol, ethyl methyl ketone or light petroleum.
4.3. Diethyl ether, peroxide-free
Note 1:
To test for peroxide, add to 10 ml of the ether in a small glass stoppered cylinder, previously rinsed with the ether, 1 ml freshly prepared 10 % potassium iodide solution. Shake and let stand for one minute. No yellow colour should be observed in either layer.
Note 2:
Diethyl ether may be maintained free from peroxides by adding wet zinc foil that has been completely immersed in dilute acidified copper sulphate solution for one minute and subsequently washed with water. Use per litre approximately 8000 mm2 zinc foil cut in strips long enough to reach at least halfway up the container.
4.4. Light petroleum (petroleum ether), with any boiling range between 30 and 60 oC.
4.5. Mixed solvent, prepared shortly before use by mixing equal volumes of diethyl ether (4.3) and light petroleum (4.4) (when the use of mixed solvent is indicated, it may be replaced by either diethyl ether or light petroleum alone).
5.1. Analytical balance.
5.2. Suitable extraction tubes or flasks, provided with ground glass stoppers or other closures unaffected by the solvents used.
5.3. Flasks, thin-walled, flat-bottomed, of 150 to 250 ml capacity.
5.4. Atmospheric pressure drying oven, well ventilated and thermostatically controlled (adjusted to operate at 102 oC ± 1 oC).
5.5. Anti-bumping granules, fat-free, non porous, non friable in use, e.g. glass beads or pieces of silicon carbide (the use of this material is optional: see clause 6.2.1).
5.6. Waterbath, at 60 to 70 oC.
5.7. Siphon to fit extraction tubes.
5.8. Centrifuge (optional).
At the same time as the determination of the fat content of the sample, carry out a blank determination on 10 ml of water using the same type of extraction apparatus, the same reagents in the same amounts and the same procedure as described hereafter, excluding clause 6.2.2. If blank exceeds 0.5 mg, the reagents should be checked and the impure reagent or reagents should be purified or replaced.
6.2.1. Dry the flask (5.3) together with, if required, some anti-bumping granules (5.5) to promote gentle boiling during the subsequent removal of the solvents) in the oven (5.4) for half to one hour. Allow the flask to cool to the temperature of the balance room and accurately, weigh the cooled flask to the nearest 0,1 mg.