Containment measures | Containment levels
2 | 3 | 4
1 | Viable micro-organisms should be contained in a system which physically separates the process from the environment (closed system). | Yes | Yes | Yes
2 | Exhaust gases from the closed system should be treated so as to— | Minimise release | Prevent release | Prevent release
3 | Sample collection, addition of materials to a closed system and transfer of viable micro-organisms to another closed system, should be performed so as to— | Minimise release | Prevent release | Prevent release
4 | Bulk culture fluids should not be removed from the closed system unless the viable micro-organisms have been— | Inactivated by validated means | Inactivated by validated chemical or physical means | Inactivated by validated chemical or physical means
5 | Seals should be designed so as to— | Minimise release | Prevent release | Prevent release
6 | Closed systems should be located within a controlled area— | Optional | Optional | Yes, and purpose-built
(a)biohazard signs should be posted;
Optional | Yes | Yes
(b)access should be restricted to nominated personnel only;
Optional | Yes | Yes, via air-lock
(c)personnel should wear protective clothing;
Yes, work clothing | Yes | Yes, a complete change
(d)decontamination and washing facilities should be provided for personnel;
Yes | Yes | Yes
(e)personnel should shower before leaving the controlled area;
No | Optional | Yes
(f)effluent from sinks and showers should be collected and inactivated before release;
No | Optional | Yes
(g)the controlled area should be adequately ventilated to minimise air contamination;
Optional | Optional | Yes
(h)the controlled area should be maintained at an air pressure negative to atmosphere;
No | Optional | Yes
(i)input and extract air to the controlled area should be HEPA filtered;
No | Optional | Yes
(j)the controlled area should be designed to contain spillage of the entire contents of closed system;
Optional | Yes | Yes
(k)the controlled area should be sealable to permit fumigation.
No | Optional | Yes
7 | Effluent treatment before final discharge. | Inactivated by validated means | Inactivated by validated chemical or physical means | Inactivated by validated physical means