, The Environmental Authorisations (Scotland) Regulations 2018

In forcesince 1 Nov 2025

Table 1

Concentration of radionuclides: NORM industrial activities

Radionuclide | Solid or relevant liquid concentration in becquerels per gram (Bq/g) | Any other liquid concentration becquerels per litre (Bq/l) | Gaseous concentration in becquerels per cubic metre (Bq/m3)

U-238sec | 1 | 0.1 | 0.001

U-238+ | 5 | 10 | 0.01

U-234 | 5 | 10 | 0.01

Th-230 | 10 | 10 | 0.001

Ra-226+ | 1 | 1 | 0.01

Pb-210+ | 5 | 0.1 | 0.01

Po-210 | 5 | 0.1 | 0.01

U-235sec | 1 | 0.1 | 0.0001

U-235+ | 5 | 10 | 0.01

Pa-231 | 5 | 1 | 0.001

Ac-227+ | 1 | 0.1 | 0.001

Th-232sec | 1 | 0.1 | 0.001

Th-232 | 5 | 10 | 0.001

Ra-228+ | 1 | 0.1 | 0.01

Th-228+ | 1 | 1 | 0.001

Changed on 1 Nov 2025

Column 1 | Column 2 Activity | General Binding Rules 1. The management of a category 5 sealed source. | The radioactive substances common rules; a non-metallic category 5 sealed source must only be disposed of in normal refuse; the activity of an individual category 5 sealed source disposed of must not exceed 2 × 105 Table 1 Concentration of radionuclides: NORM industrial activities Radionuclide | Solid or relevant liquid concentration in becquerels per gram (Bq/g) | Any other liquid concentration becquerels; more than one source must not be disposed of in any 0.1 m3 of normal refuse; the total activity of category 5 sealed sources disposed of in normal refuse from premises in a year must not exceed 1 × 107 becquerels; a metallic category 5 sealed source must only be disposed of by landfill. 2. The management of a smoke detector. | The total number of smoke detectors kept on a premises, and not affixed to the premises, must not exceed 500. a smoke detector must be managed in a manner which prevents the dispersal of radionuclides; a smoke detector must only be disposed of in normal refuse; more than one smoke detector must not be disposed of in any 0.1 m3 of normal refuse. 3. The management of a tritium source. | The radioactive substances common rules; the total activity of tritium sources, other than Class B gaseous tritium light devices and Class C gaseous tritium light devices, on a premises must not exceed 5 × 1012 becquerels; the total activity of Class B gaseous tritium light devices and Class C gaseous tritium light devices on a premises must not exceed 3 × 1013 becquerels; a tritium source with an activity greater than 2 × 1010 becquerels must not be disposed of; a tritium source must only be disposed of in normal refuse; more than one tritium source must not be disposed of in any 0.1 m3 of normal refuse; the total activity of tritium sources disposed of in normal refuse from a premises in a year must not exceed 1 × 1013 becquerels. 4. The management (other than the disposal) of an electrodeposited source. | The radioactive substances common rules. 5. The management of a barium eluting source. | The radioactive substances common rules; the total activity of all barium eluting sources kept on a premises must not exceed 4 × 105 becquerels of Cs-137+; a waste barium eluting source must only be disposed of in normal refuse; more than one barium eluting source must not be disposed of in any 0.1 m3 of normal refuse; 6. The management of a thorium alloy. | The radioactive substances common rules; a thorium alloy must only be disposed of by landfill. 7. The management of a uranium or thorium compound. | The radioactive substances common rules; a uranium or thorium compound which is solid waste must only be disposed of in normal refuse; the total quantity of uranium or thorium in a uranium or thorium compound disposed of from a premises in normal refuse must not exceed 0.5 kilogrammes per week; a uranium or thorium compound which is aqueous waste must be disposed of to a relevant sewer; the total quantity of uranium or thorium in a uranium or thorium compound disposed of from a premises to a relevant sewer must not exceed 0.5 kilogrammes per year. 8. The management of a medical or veterinary radioactive substance. | The radioactive substances common rules; a medical or veterinary radioactive substance must only be— disposed of in normal refuse; or disposed into— a relevant sewer; a river, which at the time of any disposal into it of aqueous radioactive waste has a flow rate which is not less than 1m3s-1; or the sea; a single item of medical or veterinary radioactive waste must not be disposed of in normal refuse if its activity exceeds— 4 × 105 becquerels for tritium or C-14; or 4 × 104 becquerels for any other radionuclide; the total activity of medical or veterinary radioactive waste disposed of per 0.1 m3 of normal refuse must not exceed— 4 × 106 becquerels for tritium or C-14; or 4 × 105 becquerels for any other radionuclide; the total activity of medical or veterinary waste disposed of in normal refuse from a premises in a year must not exceed— 2 × 109 becquerels for tritium or C-14; or 2 x 108 becquerels for any other radionuclide; if the medical or veterinary waste consists of human excreta, the total activity of liquid aqueous waste disposed of from a premises to a relevant sewer in a year must not exceed— 1 x 1010 becquerels for Tc-99m; or 5 x 109 becquerels for the sum of all other radionuclides; if the medical or veterinary waste does not consist of human excreta, the total activity of liquid aqueous waste disposed of from a premises to a relevant sewer in a year must not exceed— 1 x 108 becquerels for the sum of the following radionuclides: H-3, C-11, C-14, F-18, P-32, P-33, S-35, Ca-45, Cr-51, Fe-55, Ga-67, Sr-89, Y-90, Tc-99m, In-111, I-123, I-125, I-131, Sm-153, Tl-201; or 1 x 106 becquerels for the sum of all other radionuclides; if the waste does not consist of human excreta, the concentration of liquid aqueous waste disposed of from a premises to a relevant sewer must not exceed 100 becquerels per millilitre. 9. The management (other than disposal) of a NORM containing substance. | The radioactive substances common rules; the total activity of NORM containing substances transferred from a premises in a year to a person for disposal in a landfill must not exceed the value specified in column 3 of Table 1; the total activity of NORM containing substances transferred from a premises in a year to a person for incineration must not exceed the value specified in column 4 of Table 1. 10. The disposal of gaseous radioactive waste which— | The total amount of gaseous Kr-85 waste disposed of from premises in a year must not exceed 1 × 1011 becquerels; gaseous Kr-85 waste must be adequately dispersed from the building in which it arose so that it does not enter, or re-enter, a building. contains no radionuclides other than Kr-85; and arises from lamps containing Kr-85. 11. Any other radioactive substances activity, not falling within any other activity description in this schedule, where— | The radioactive substances common rules; the total activity of a radionuclide does not exceed the value specified in column 2 of Table 2; or a solid radioactive substance must only be disposed of in normal refuse; the concentration of radioactivity of a radionuclide does not exceed the value specified in column 3 of Table 2. a single item of radioactive waste must not be disposed of in normal refuse if it exceeds— 4 × 105 becquerels for tritium or C-14; or 4 × 104 becquerels for any other radionuclide; the total activity of radioactive substances disposed of per 0.1 m3 of normal refuse must not exceed— 4 × 106 becquerels for tritium or C-14; or 4 × 105 becquerels for any other radionuclide; an aqueous liquid radioactive substance must only be disposed of into— a relevant sewer; a river, which at the time of any disposal into it of aqueous radioactive waste has a flow rate which is not less than 1m3s-1; or the sea; the total activity of liquid aqueous radioactive waste disposed of from a premises in a year must not exceed— 1 x 108 becquerels for the sum of the following radionuclides: H-3, C-11, C-14, F-18, P-32, P-33, S-35, Ca-45, Cr-51, Fe-55, Ga-67, Sr-89, Y-90, Tc-99m, In-111, I-123, I-125, I-131, Sm-153, T1-201; or 1 x 106 becquerels for the sum of all other radionuclides; the concentration of liquid aqueous radioactive waste disposed of from a premises must not exceed 100 becquerels per millilitre; gaseous waste must not be disposed of unless— it consists of fugitive releases from a container; and it is dispersed from a building in such a way that it does not enter or re-enter a building. per litre (Bq/l) | Gaseous concentration in becquerels per cubic metre (Bq/m3) U-238sec | 1 | 0.1 | 0.001 U-238+ | 5 | 10 | 0.01 U-234 | 5 | 10 | 0.01 Th-230 | 10 | 10 | 0.001 Ra-226+ | 1 | 1 | 0.01 Pb-210+ | 5 | 0.1 | 0.01 Po-210 | 5 | 0.1 | 0.01 U-235sec | 1 | 0.1 | 0.0001 U-235+ | 5 | 10 | 0.01 Pa-231 | 5 | 1 | 0.001 Ac-227+ | 1 | 0.1 | 0.001 Th-232sec | 1 | 0.1 | 0.001 Th-232 | 5 | 10 | 0.001 Ra-228+ | 1 | 0.1 | 0.01 Th-228+ | 1 | 1 | 0.001

  1. 1 Nov 2025 – todayin force
  2. 28 Jun 2018 – 1 Nov 2025earlier wording