, Control of Substances Hazardous to Health Regulations (Northern Ireland) 2003

In forcesince 28 Feb 2003

Containment measures | Containment levels

2 | 3 | 4

1.

Viable micro-organisms should be contained in a system which physically separates the process from the environment (closed system).

Yes. | Yes. | Yes.

2.

Exhaust gases from the closed system should be treated so as to–

minimise release. | prevent release. | prevent release.

3.

Sample collection, addition of materials to a closed system and transfer of viable micro-organisms to another closed system, should be performed so as to–

minimise release. | prevent release. | prevent release.

4.

Bulk culture fluids should not be removed from the closed system unless the viable micro-organisms have been–

inactivated by validated means. | inactivated by validated chemical or physical means. | inactivated by validated chemical or physical means.

5.

Seals should be designed so as to–

minimise release. | prevent release. | prevent release.

6.

Closed systems should be located within a controlled area–

Optional. | Optional. | Yes and purpose built.

(a)

biohazard signs should be posted;

Optional. | Yes. | Yes.

(b)

access should be restricted to nominated personnel only;

Optional. | Yes. | Yes, via air-lock.

(c)

personnel should wear protective clothing;

Yes, work clothing. | Yes. | Yes, a complete change.

(d)

decontamination and washing facilities should be provided for personnel;

Yes. | Yes. | Yes.

(e)

personnel should shower before leaving the controlled area;

No. | Optional. | Yes.

(f)

effluent from sinks and showers should be collected and inactivated before release;

No. | Optional. | Yes.

(g)

the controlled area should be adequately ventilated to minimise air contamination;

Optional. | Optional. | Yes.

(h)

the controlled area should be maintained at an air pressure negative to atmosphere;

No. | Optional. | Yes.

(i)

input and extract air to the controlled area should be HEPA filtered;

No. | Optional. | Yes.

(j)

the controlled area should be designed to contain spillage of the entire contents of closed system;

Optional. | Yes. | Yes.

(k)

the controlled area should be sealable to permit fumigation.

No. | Optional. | Yes.

7.

Effluent treatment before final discharge.

Inactivated by validated means. | Inactivated by validated chemical or physical means. | Inactivated by validated physical means.