Containment measures | Containment levels
2 | 3 | 4
The workplace is to be separated from any other activities in the same building.
No. | Yes. | Yes.
Input air and extract air to the workplace are to be filtered using HEPA or equivalent.
No. | Yes, on extract air. | Yes, on input and double on extract air.
Access is to be restricted to authorised persons only.
Yes. | Yes. | Yes, via air-lock key procedure.
The workplace is to be sealable to permit disinfection.
No. | Yes. | Yes.
Specified disinfection procedures.
Yes. | Yes. | Yes.
The workplace is to be maintained at an air pressure negative to atmosphere.
No. | Yes. | Yes.
Efficient vector control e.g. rodents and insects.
Yes, for animal containment. | Yes, for animal containment. | Yes.
Surfaces impervious to water and easy to clean.
Yes, for bench. | Yes, for bench and floor (and walls for animal containment). | Yes for bench, floor, walls and ceiling.
Surfaces resistant to acids, alkalis, solvents, disinfectants.
Yes, for bench. | Yes, for bench and floor (and walls for animal containment). | Yes, for bench, floor, walls and ceiling.
Safe storage of biological agents.
Yes. | Yes. | Yes, secure storage.
An observation window, or alternative, is to be present, so that occupants can be seen.
No. | Yes. | Yes.
A laboratory is to contain its own equipment.
No. | Yes, so far as is reasonably practicable. | Yes.
Infected material, including any animal, is to be handled in a safety cabinet or isolator or other suitable containment.
Yes, where aerosol produced. | Yes, where aerosol produced. | Yes.
Incinerator for disposal of animal carcases.
Accessible. | Accessible. | Yes, on site.