Table 1a:
Containment measures for activities involving genetic modification of micro-organisms in laboratories
Containment Measures | Containment Levels
1 | 2 | 3 | 4
NOTES
In the Table above, “isolation” means, in relation to a laboratory, separation of the laboratory from other areas in the same building, or being in a separate building.
Entry must be through an airlock which is a chamber isolated from the laboratory. The clean side of the airlock must be separated from the restricted side by changing or showering facilities and preferably by interlocking doors.
Where viruses are not retained by the HEPA filters, extra requirements will be necessary for extract air.
Where the autoclave is outside the laboratory in which the activity involving genetic modification of micro-organisms is being undertaken, but within the laboratory suite, there shall be validated procedures for the safe transfer of material into that autoclave, which provide a level of protection equivalent to that which would be achieved by having an autoclave in that laboratory.
1 Laboratory suite: isolation (Note 1)
not required | not required | required | required
2 Laboratory: sealable for fumigation
not required | not required | required | required
Equipment
3 Surfaces impervious to water, resistant to acids, alkalis, solvents, disinfectants and decontamination agents and easy to clean
required for bench | required for bench | required for bench and floor | required for bench, floor ceiling and walls
4 Entry to lab via airlock (Note 2)
not required | not required | required where and to extent the risk assessment shows it is required | required
5 Negative pressure relative to the pressure of the immediate surroundings
not required | required where and to extent the risk assessment shows it is required | required | required
6 Extract and input air from the laboratory shall be HEPA filtered
not required | not required | HEPA filters required for extract air | HEPA filters required for input and extract air (Note 3)
7 Microbiological safety cabinet/enclosure
not required | required where and to extent the risk assessment shows it is required | required, and all procedures with infective materials required to be contained within a cabinet/ enclosure | Class III cabinet required
8 Autoclave
required on site | required in the building | required in the laboratory suite (Note 4) | double ended autoclave required in laboratory
System of work
9 Access restricted to authorised personnel only
not required | required | required | required (via airlock key procedure)
10 Specific measures to control aerosol dissemination
not required | required so as to minimise | required so as to prevent | required so as to prevent
11 Shower
not required | not required | required where and to extent the risk assessment shows it is required | required
12 Protective clothing
suitable protective clothing required | suitable protective clothing required | suitable protective clothing required; footwear required where and to extent the risk assessment shows it is required | complete change of clothing and footwear required before entry and exit
13 Gloves
not required | required where and to extent the risk assessment shows they are required | required | required
14 Efficient control of disease vectors (eg rodents and insects) which could disseminate GMMs
required where and to extent the risk assessment shows it is required | required | required | required
15 Specified disinfection procedures in place
required where and to extent the risk assessment shows they are required | required | required | required
Waste
16 Inactivation of GMMs in effluent from handwashing sinks and showers and similar effluents
not required | not required | required where and to extent the risk assessment shows it is required | required
17 Inactivation of GMMs in contaminated material and waste
required by validated means | required by validated means | required by validated means, with waste inactivated within the laboratory suite | required by validated means, with waste inactivated within the laboratory
Other measures
18 Laboratory to contain its own equipment
not required | not required | required, so far as is reasonably practicable | required
19 An observation window or alternative is to be present so that occupants can be seen
required where and to extent the risk assessment shows it is required | required where and to extent the risk assessment shows it is required | required | required
20 Safe storage of GMMs
required where and to extent the risk assessment shows it is required | required | required | secure storage required
21 Written records of staff training
not required | required where and to extent the risk assessment shows they are required | required | required
Table 1b:
Containment measures for activities involving genetic modification of micro-organisms in plant growth facilities (to be read with Table 1a as indicated in paragraph 3)
Containment Measures | Containment Levels | Additional/ modification
1 | 2 | 3 | 4 |
NOTE
A permanent structure refers to a fixed structure with walls, a roof and a floor. Where the permanent structure is a greenhouse, that structure shall also have a continuous waterproof covering and self-closing lockable outer doors, and be located on a site designed to prevent the entry of surface run-off water.
Building
1 Permanent structure (Note 1)
required where and to extent the risk assessment shows it is required | required | required | required | Modification
Equipment
2 Entry via a separate room with two interlocking doors
not required | required where and to extent the risk assessment shows it is required | required where and to extent the risk assessment shows it is required | required (via airlock key procedure) | Additional
3 Control of contaminated run-off water
required where and to extent the risk assessment shows it is required | required so as to minimise run-off | required so as to prevent run-off | required so as to prevent run-off | Additional
System of work
4 Effective control of disease vectors such as insects, rodents and arthropods which could disseminate GMMs
required | required | required | required | Additional
5 Effective control of pollen, seeds and other plant material which could disseminate GMMs
required where and to extent the risk assessment shows it is required | required so as to minimise dissemination | required so as to prevent dissemination | required so as to prevent dissemination | Additional
6 Procedures for transfer of living material between the plant growth facilities, protective structure and laboratory shall control dissemination of GMMs
required so as to minimise dissemination | required so as to minimise dissemination | required so as to prevent dissemination | required so as to prevent dissemination | Additional
Table 1c:
Containment measures for activities involving genetic modification of micro-organisms in animal units (to be read with Table 1a as indicated in paragraph 3)
Containment Measures | Containment Levels | Additional/modification
1 | 2 | 3 | 4 |
NOTES
In the Table above, “animal unit” means a building, or separate area within a building, containing an animal facility and other areas including changing rooms, showers, autoclaves and food storage areas.
In the Table above and in Note 1 above, “animal facility” means a facility normally used to house stock, breeding or experimental animals or one which is used for the performance of minor surgical procedures on animals.
In the Table above, “isolators” means transparent boxes where small animals are contained within or outside a cage; for large animals, isolated rooms may be more appropriate.
Facilities
1 Isolation of animal unit (Note 1)
required where and to extent the risk assessment shows it is required | required | required | required | Modification
2 Animal facilities (Note 2) separatedwhere and by lockable doors
required to extent the risk assessment shows they are required | required | required | required | Additional
3 Animal facilities (cages, etc) designed to facilitate decontamination (waterproof and easily washable material)
required where and to extent the risk assessment shows they are required | required where and to extent the risk assesment shows they are required | required | required | Additional
4 Floor, walls and ceiling easily washable
required where and to extent the risk assessment shows they are required | required for floor | required for floor and walls | required for floor, walls and ceiling | Modification
5 Appropriate filters on isolators or isolated rooms (Note 3)
not required | required where and to extent the risk assessment shows they are required | required | required | Additional
6 Incinerator for disposal of animal carcasses
required to be accessible | required to be accessible | required to be accessible | required to be on site | Additional
7 Appropriate barriers at the room exit, and at drains or ventilation duct work
required | required | required | required | Additional
8 Animals kept in appropriate containment facilities, such as cages, pens or tanks but not isolators
required where and to the extent the risk assessment shows it is required | required where and to the extent the risk assessment shows it is required | required where and to the extent the risk assessment shows it is required | required where and to the extent the risk assessment shows it is required | Additional
(9) Animals kept in isolators
required where and to the extent the risk assessment shows it is required | required where and to the extent the risk assessment shows it is required | required | required | Additional
Table 2:
Containment measures for activities involving genetic modification of micro-organisms in premises other than those referred to in Tables 1a, 1b and 1c
Containment Measures | Containment Levels
1 | 2 | 3 | 4
General
1 Viable micro-organisms shall be contained in a system which separates the process from the workplace and wider environment (closed system)
required where and to extent the risk assessment shows it is required | required | required | required
2 Closed systems located within a controlled area
not required | required where and to extent the risk assessment shows they are required | required | required and required to be purpose built
3 Control of exhaust gases from the closed system
not required | required so as to minimise release | required so as to prevent release | required so as to prevent release
4 Control of aerosols during sample collection, addition of material to a closed system or transfer of material to another closed system
required where and to extent the risk assessment shows it is required | required so as to minimise release | required so as to prevent release | required so as to prevent release
5 Inactivation of bulk culture fluids before removal from the closed system
required where and to extent the risk assessment shows it is required | required by validated means | required by validated means | required by validated means
6 Seals shall be designed so as to minimise or prevent release
not required | required so as to minimise release | required so as to prevent release | required so as to prevent release
7 The controlled area designed to contain spillage of the entire contents of the closed system
required where and to extent the risk assessment shows it is | required where and to extent the risk assessment shows it is required | required required | required
8 The controlled area sealable to permit fumigation
not required | required where and to extent the risk assessment shows it is required | required where and to extent the risk assessment shows it is required | required
9 Biohazard signs posted
required where and to extent the risk assessment shows it is required | required | required | required
Equipment
10 Entry via airlock
not required | not required | required where and to extent the risk assessment shows it is required | required
11 Surfaces resistant to water, acids, alkalis, solvents, disinfectants and decontamination agents and easy to clean
required for any bench | required for any bench | required for floor and any bench | required for bench, floor, ceiling and walls
12 Specific measures to adequately ventilate the controlled areas in order to minimise air contamination
required where and to extent the risk assessment shows they are required | required where and to extent the risk assessment shows they are required | required where and to extent the risk assessment shows they are required | required
13 The controlled area maintained at an air pressure negative to the immediate surroundings
not required | not required | required where and to extent the risk assessment shows it is required | required
14 Extract and input air from the controlled area shall be HEPA filtered
not required | not required | required for extract air, optional for input air | required for input and extract air
System of work
15 Access restricted to authorised personnel only
not required | required | required | required
16 Decontamination and washing facilities provided for personnel
required | required | required | required
17 Personnel shall shower before leaving the controlled area
not required | not required | required where and to extent the risk assessment shows it is required | required
18 Personnel shall wear protective clothing
work clothing required | work clothing required | required | complete change required before exit and entry
19 Written procedures and records of staff training
not required | not required | required | required
Waste
20 Inactivation of GMMs in effluent from handwashing sinks and showers or similar effluents
not required | not required | required where and to extent the risk assessment shows it is required | required
21 Inactivation of GMMs in contaminated material and waste including those in process effluent before final discharge
required by validated means | required by validated means | required by validated means | required by validated means…