The reference model for the customer switching supplier process, that is to say the change of supplier, consists of a set of reference procedures for access to data and regarding the required information exchanges between the relevant different roles performed by market parties.
The tables in this Annex reflect that set of information which constitutes the reference model. The procedural steps set out in this Annex may be combined or carried out in a different order when applied at national level.
Table I contains information on the national market structure and environment, serving as a valuable resource for electricity suppliers seeking to set up their operations in the territory of a Member State and offer services to final customers in that Member State.
Table I also lists information needed to enable final customers to choose a new supplier and electricity suppliers to register, on-board, or set up the necessary infrastructure to take part in the procedures described in Table III. Those procedures also facilitate communication and exchange of information with relevant market participants occupying the roles and undertaking the responsibilities set out in Table II.
Table I and Table II of this Annex should be read in conjunction with Table I ‘General information on Member State environments’ and Table II ‘Roles’ set out in the Annex to Implementing Regulation (EU) 2023/1162.
ID | Name | Description
I-s1 | Information about entity publishing list of active electricity suppliers operating in the Member State | Name of entity making the information publicly available | Name of the organisation, which is responsible for registering and publishing information about active electricity suppliers in a publicly available register in the Member State.
Website | If applicable, link to the website that is used to publish information about active electricity suppliers in the Member State.
Official contact | Contact details of the entity responsible for registering and publishing information about active electricity suppliers in the Member State.
I-s2 | Information about active electricity suppliers in the Member State | Link to a website or a document that is nationally published and kept up to date providing this information including name of electricity suppliers, their identification code (e.g. Legal Entity Identifier (LEI), European Article Number (EAN)) and official contact details.
I-s3 | Information about entity publishing list of active balance responsible parties in the Member State | Name | Name of the organisation, which is responsible for registering and publishing information about active balance responsible parties in a publicly available register in the Member State.
Website | If applicable, link to the website that is used to publish information about active balance responsible parties in the Member State.
Official contact | Contact details of the entity responsible for registering and publishing information about active balance responsible parties in the Member State.
I-s4 | Information about balance responsible parties in the Member State | Link to a website or a document that is nationally published kept up to date providing this information including name of balance responsible parties, their identification code (e.g. European Legal Entity Identifier (EUEI), European Article Number (EAN)) and official contact details.
[The market participants listed in this table are eligible parties, as defined in point (6) of Article 2 of Implementing Regulation (EU) 2023/1162, that perform a specific service for the accounting point involved in and impacted by the execution of the procedures set out in Table III. Each eligible party assumes full responsibility for the performance of its designated duties.]
Name | Type | Description
Roles | Balance responsible party | Business |
As defined in point (14) of Article 2 of Regulation (EU) 2019/943.
A ‘balance responsible party’ is a market participant or its chosen representative responsible for its imbalances in the electricity market.
Electricity supplier or supplier | Business | As defined in point (1) of Article 2 of the present Regulation.
Other
market participants
Affected party | Business |
As defined in point (14) of Article 2 of the present Regulation.
This market participant gains or loses responsibility for the accounting point concerned as a direct result of the switching supplier process or the cancellation of that process.
Note: ‘affected parties’ include the current and new electricity supplier, balance responsible party, metered data administrator and grid access provider.
Entitled party | Business |
As defined in point (13) of Article 2 of the present Regulation.
This market participant should be informed about changes made in the metering point register by the metering point administrator, or the delegated entity where Member States have so provided, as a result of the switching supplier process or the cancellation of that process.
Note: ‘entitled parties’ include the metered data aggregator, flexibility service provider, register of guarantees of origin of renewable energy sources and control area manager.
All roles classified as ‘Business’ are to operate in a secure, authenticated manner and through trusted communication channels. As such, the specific authentication steps used for such communication exchanges are not detailed in the procedures outlined in Table III but are instead considered essential prerequisites. That applies to both the ‘switching supplier’ procedure and the ‘cancellation of switching supplier’ procedure. For instance, for ‘switching supplier’, as soon as the final customer requests a change of supplier, the new supplier must authenticate and validate the customer’s credentials. To mitigate risks of fraud and identity theft, electricity suppliers should rely on solutions that preferably leverage at least two authentication factors to effectively verify a customer’s identity. In that context, the identity service provider can offer authentication services pursuant to Implementing Regulation (EU) 2023/1162, providing an additional layer of security and compliance.
No. | Procedure name | Primary actor | Pre-conditions
1 | Switching supplier | Final customer |
The new supplier is registered as an electricity supplier.
The new supplier has authenticated the final customer.
The new supplier has identified the accounting point concerned.
The new supplier has obtained permission from the final customer to perform preparatory activities; permission can be provided through the permission administrator.
2 | Cancellation of switching supplier | Final customer |
The final customer has a supply contract with the new supplier.
The supply of electricity based on the new contract has not yet started.
For the purposes of this Regulation, customer switching referred to in Article 23(1) of Directive (EU) 2019/944 is understood as the process by which a final customer switches their electricity supplier. The scope of the reference model in this Annex is limited to the core procedures for ‘switching supplier’ (Table III.1) and ‘cancellation of switching supplier’ (Table III.2). While customer switching may also involve changing an aggregator, in accordance with Article 12 of Directive (EU) 2019/944, or energy sharing organiser in accordance with Article 2 point (5) of Directive (EU) 2024/1711, this Regulation specifically addresses only the switching of electricity suppliers.
All procedures discussed in this Annex represent the ‘happy flow’, which refers to the standard or expected path where all conditions are met, and actions proceed smoothly without encountering issues such as data mismatches, errors, or deviations. The happy flow ensures the successful execution of the process and the achievement of the desired outcome.
The procedure ‘switching supplier’, as detailed in Table III.1, includes the registration of the new supplier at the accounting point according to the date specified in the supply contract. The actual registration of the new electricity supplier, initiated in the procedural step 1.13, after the conclusion of the contract, and performed as set out in procedural step 1.19 in Table III.1, is carried out by the metering point administrator, or the delegated entity where Member States have so provided, in the metering point register. That step is followed by notifying the change to all entitled and affected parties. The overall technical process for switching electricity supplier, that is the process of registering a new supplier at a metering point with the market operator, in accordance with Article 12(1) of Directive (EU) 2019/944, includes procedural steps 1.13 to 1.19 set out in Table III.1 and is to be completed within 24 hours by no later than 2026. The streamlined process in Table III.1 aligns with the right to switch electricity supplier, guaranteed by Directive (EU) 2019/944.
It is essential that the procedural steps set out in this Annex are understood as facilitating the switching process, minimising barriers, and respecting consumer choice. In accordance with Directive (EU) 2019/944, the current supplier must not obstruct or delay the switch. Provided they meet contractual conditions, customers are entitled to switch suppliers in a manner that is non-discriminatory for cost, effort, or time, thereby ensuring compliance with the principles of transparency, consumer empowerment, and market competition.
The procedure ‘cancellation of switching supplier’ allows for the revocation of a supplier switch notification initiated through the ‘switching supplier’ procedure. As set out in Table III.2, the implementation of that procedure is to a certain extent dependent on national rules governing the application of final customer’s right to cancel the new supply contract within the allowed withdrawal period. In national settings, a standard sub-procedure based on contractual law, and linked to the withdrawal period, may be used, which is applicable across all sectors, including the electricity sector, as well as for all services and goods. As a result, steps of the ‘cancellation of switching supplier’ procedure are to be understood and implemented without affecting the national rules and procedures for handling the allowed withdrawal period.
One of the key pre-conditions for performing the ‘cancellation of switching supplier’ procedure, set out in Table III.2, is that the electricity supply based on the new contract has not yet begun. In that scenario, the final customer will remain with their current supplier after completing the ‘cancellation of switching supplier’ procedure. However, if a final customer wishes to cancel their switch to a new supplier after the supply has started, they must instead initiate the ‘switching supplier’ procedure, or another equivalent procedure in accordance with national consumer protection law, since at that point the new supplier becomes the customer's current supplier, and the ‘cancellation of switching supplier’ procedure is no longer applicable.
The business partners identified in Table II and listed in the procedures set out therein are parties associated with the accounting point and are distinguished by their direct (‘affected parties’) or indirect interest (‘entitled parties’) in the change of supplier process.
The information objects exchanged in procedure 1 (Table III.1) and in procedure 2 (Table III.2) are identified with unique references under the column headed ‘Information exchanged (IDs)’ set out in Table III.1 and Table III.2. Table IV lists those information objects, along with their descriptions.
Diagram 1 and Diagram 2 illustrate the procedures described in Table III.1 and Table III.2 and follow the Object Management Group Business Process Model and Notation 2.0 [Object Management Group Business Process Model and Notation 2.0, https://www.omg.org/spec/BPMN/2.0.2/PDF.].
Procedure name | Switching supplier
Step No | Step | Step description | Information producer | Information receiver | Information exchanged (IDs)
1.1 | Contact between final customer and new supplier | The final customer (or the potential new supplier) makes contact to request (or provide) an offer, which may lead to a new electricity supply contract and the ending of the existing contract with the current supplier. | Final customer (or new supplier) | New supplier (or final customer) | A
1.1a Request supplier change
The final customer triggers the switching. | Final customer | New supplier
1.1b Notify on supplier change
The new supplier triggers the switching. | New supplier | Final customer
1.2 |
[Optional step depending on national arrangements]
Check for possible contractual constraints
Depending on national rules, the new supplier checks for any potential contractual constraints in the current supply contract that could impact the activation of the new supply contract.
Note: This verification process involving steps 1.2 to 1.4, must not impede or delay the switching process and must respect the final customer’s right to switch suppliers without undue barriers or discrimination.
New supplier | New supplier | [Not relevant]
1.3 |
[Conditional – if step 1.2 is implemented]
Resolve issues with current supplier
The new supplier provides – upon any required permission from the final customer – the necessary information to resolve any identified contractual constraints with the current supplier for the activation of the new supply contract.
Note: The resolution process must be conducted transparently and must not hinder or obstruct the customer’s ability to switch suppliers in a timely and non-discriminatory manner, as guaranteed under Directive (EU) 2019/944.
New supplier | Current supplier | [Not relevant]
1.4 |
[Conditional – if step 1.2 is implemented]
Communicate resolution results
The current supplier informs the new supplier of the resolution results.
Note: This communication is purely procedural and does not grant the current supplier the authority to veto or delay the switching process, ensuring that the customer’s right to switch suppliers is upheld without undue cost, effort, or time.
Current supplier | New supplier | [Not relevant]
1.5 |
[Conditional – if step 1.2 is implemented]
Notify final customer of issue resolution results
The new supplier informs the final customer of the issue resolution result.
Note: If no go, then final customer remains with current supplier; otherwise proceeds to 1.6.
New supplier | Final customer | B
1.6 | Validate need for accounting point characteristics |
The new supplier decides whether accounting point characteristics are required in advance.
Note: If steps 1.7 to 1.10 do not apply, then flow moves to step 1.11.
New supplier | New supplier | [Not relevant]
1.7 |
[Optional]
Request upfront accounting point characteristics
The new supplier, with the final customer’s permission, requests in advance the accounting point characteristics from the metering point administrator, or delegated entity. | New supplier | Metering point administrator, or delegated entity | C
1.8 |
[Conditional – if step 1.7 is implemented]
Validate upfront accounting point characteristics’ request
The metering point administrator, or delegated entity, validates the accounting point characteristics’ request. | Metering point administrator, or delegated entity | Metering point administrator, or delegated entity | [Not relevant]
1.9 |
[Conditional – if step 1.7 is implemented]
Provide accounting point characteristics
The metering point administrator, or delegated entity, sends the requested accounting point characteristics to the new supplier or provides a meaningful indication in case of an invalid request. | Metering point administrator, or delegated entity | New supplier | D
1.10 |
[Conditional – if step 1.7 is implemented]
Notify final customer of accounting point validation results
The new supplier informs the final customer about the accounting point validation result. | New supplier | Final customer | B
1.11 | Request contract conclusion | The new supplier invites the final customer to conclude the new contract, for supply of electricity at the requested date. | New Supplier | Final customer | O
1.12 | Conclude contract | The final customer concludes the contract for supply of electricity at the requested date. | Final customer | New supplier | O
Technical Switching: steps 1.13 to 1.19
1.13 | Request switch of supplier | The new supplier submits a request to the metering point administrator, or delegated entity, to be registered as the new supplier (alongside the balance responsible party) in the metering point register for the accounting point on the specified date. | New supplier | Metering point administrator, or delegated entity | E
1.14 | Validate switch of supplier request | The metering point administrator, or delegated entity, validates the specified switch supplier request. | Metering point administrator, or delegated entity | Metering point administrator, or delegated entity | [Not relevant]
1.15 | Communicate validation results for switch of supplier request | The metering point administrator, or delegated entity, informs the new supplier of the validation results for the requested change of supplier at the accounting point. In case of an invalid request, a meaningful response is provided. | Metering point administrator, or delegated entity | New supplier | F
1.16 | Notify final customer of supplier switch results | The new supplier notifies the final customer of the supplier switch results as soon as available. This can take place, where technically feasible, within the 24 hours window of technical switching. | New supplier | Final customer | B
1.17 | Notify affected parties of supplier switch | The metering point administrator, or delegated entity notifies all affected parties directly after successfully validating the switch of supplier request. | Metering point administrator, or delegated entity | Affected party | H
1.18 | Registration of new supplier in metering point register | The metering point administrator, or delegated entity registers the new supplier (along with the balance responsible party) in the metering point register as the supplier for the accounting point, effective as of the specified date. The metering point administrator, or delegated entity, also makes all necessary updates to complete the switch of supplier. | Metering point administrator, or delegated entity | Metering point administrator, or delegated entity | [Not relevant]
1.19 | Notify accounting point characteristics to entitled parties and affected parties | Entitled parties and affected parties receive updated accounting point characteristics resulting from the switch of supplier registration process at the specified date of the change of supplier. | Metering point administrator, or delegated entity |
Entitled party
Affected party
G
1.20 | Request metering data | The current and new supplier request the metering data for the effective date of the change of supplier at the accounting point to ensure accurate billing. | Current and new supplier | Metered data administrator, or delegated entity | Implementing Regulation (EU) 2023/1162 – Annex – Table IV (Information Exchanged ID – C)
1.21 | Validate metering data | The metered data administrator, or delegated entity, validates the metering data request. | Metered data administrator, or delegated entity | Metered data administrator, or delegated entity | [Not relevant]
1.22 | Send metering data | The metered data administrator, or delegated entity, sends the requested metering data to the current and new supplier and provides a meaningful response in case of an invalid request. | Metered data administrator, or delegated entity | New supplier | Implementing Regulation (EU) 2023/1162 – Annex – Table IV (Information Exchanged ID – E)
[In case of a failed validation, the sequence of steps 2.7 and 2.10 applies. The metering point administrator, or delegated entity, informs the new supplier of the failed validation, who subsequently informs the final customer, as illustrated in Diagram 2 (red dotted lines).]
Procedure name | Cancellation of switching supplier
Step No | Step | Step description | Information producer | Information receiver |
Information
exchanged (IDs)
2.1 | Request cancellation of new supply contract | Final customer submits request to cancel the new supply contract to the newly contracted supplier. | Final customer | New supplier | J
2.2 | Validate cancellation request |
The new supplier verifies:
the existence of a contract with the final customer for the specified accounting point;
that the cancellation request was made before the start date of supply specified in the new contract;
that the cancellation falls within the withdrawal period.
New supplier | New supplier | [Not relevant]
2.3 | (Conditional of unsuccessful outcome of step 2.2) Notify final customer of validation failure | If the validation (under step 2.2) fails, the new supplier notifies the final customer with a meaningful indication, explanation of the failure, and that the cancellation request is ended. | New supplier | Final customer | B
2.4 | Validate registration of new supplier at accounting point | The new supplier validates the registration of the switch of supplier request in the metering point register in accordance with the new contract. | New supplier | New Supplier | [Not relevant]
2.5 | Request cancellation of new contract in the metering point register | The new supplier submits a request to the metering point administrator, or delegated entity, to cancel the pending switch of supplier in the metering point register due to cancellation of the new supply contract. | New supplier | Metering point administrator, or delegated entity | K
2.6 | Validate cancellation request | The metering point administrator, or delegated entity, checks if the new supplier is registered at the accounting point for supply on the start date specified in the request for cancellation of the new contract (submitted according to step 2.5). | Metering point administrator, or delegated entity | Metering point administrator, or delegated entity | [Not relevant]
2.7 | Notify new supplier of validation result | The metering point administrator, or delegated entity, informs the new supplier of the validation result. In the case of an invalid request, they provide a meaningful indication/explanation. | Metering point administrator, or delegated entity | New supplier | M
2.8 | Cancel the pending switch of supplier |
The metering point administrator, or delegated entity, cancels the pending switch of supplier registration.
Note: final customer stays with their current (before the switch) supplier.
Metering point administrator, or delegated entity | Metering point administrator, or delegated entity | [Not relevant]