76 Sub-Annex 8 Appendix 3, Regulation (EU) 2017/1151

No longer in force

1.1. This Appendix defines the method and required instrumentation to determine the REESS current and the REESS voltage of NOVC-HEVs, OVC-HEVs, PEVs and NOVC-FCHVs.

1.2. Measurement of REESS current and REESS voltage shall start at the same time as the test starts and shall end immediately after the vehicle has finished the test.

1.3. The REESS current and the REESS voltage of each phase shall be determined.

1.4. A list of the instrumentation used by the manufacturer to measure REESS voltage and current (including instrument manufacturer, model number, serial number, last calibration dates (where applicable)) during:

(a)

the Type 1 test according to paragraph 3 of this Sub-Annex,

(b)

the procedure to determine the correction coefficients according to Appendix 2 of this Sub-Annex (where applicable),

(c)

the ATCT as specified in Sub-Annex 6a

shall be provided to the approval authority.

REESS depletion is considered as a negative current.

2.1.1. The REESS current(s) shall be measured during the tests using a clamp-on or closed type current transducer. The current measurement system shall fulfil the requirements specified in Table A8/1 of this Sub-Annex. The current transducer(s) shall be capable of handling the peak currents at engine starts and temperature conditions at the point of measurement.

In order to have an accurate measurement, zero adjustment and degaussing shall be performed before the test in accordance with the instrument manufacturer's instructions.

2.1.2. Current transducers shall be fitted to any of the REESS on one of the cables connected directly to the REESS and shall include the total REESS current.

In case of shielded wires, appropriate methods shall be applied in accordance with the approval authority.

In order to easily measure the REESS current using external measuring equipment, the manufacturer should provide appropriate, safe and accessible connection points in the vehicle. If that is not feasible, the manufacturer is obliged to support the approval authority in connecting a current transducer to one of the cables directly connected to the REESS in the manner described above in this paragraph.

2.1.3. The current transducer output shall be sampled with a minimum frequency of 20 Hz. The measured current shall be integrated over time, yielding the measured value of Q, expressed in ampere-hours Ah. The integration may be done in the current measurement system.

As an alternative to paragraph 2.1. of this Appendix, the manufacturer may use the on-board current measurement data. The accuracy of these data shall be demonstrated to the approval authority.

During the tests described in paragraph 3. of this Sub-Annex, the REESS voltage shall be measured with the equipment and accuracy requirements specified in paragraph 1.1. of this Sub-Annex. To measure the REESS voltage using external measuring equipment, the manufacturers shall support the approval authority by providing REESS voltage measurement points.

For NOVC-HEVs, NOVC-FCHVs and OVC-HEVs, instead of using the measured REESS voltage in accordance with paragraph 3.1. of this Appendix, the nominal voltage of the REESS determined in accordance with IEC 60050-482 may be used.

As an alternative to paragraph 3.1. and 3.2. of this Appendix, the manufacturer may use the on-board voltage measurement data. The accuracy of these data shall be demonstrated to the approval authority.

Changed on 1 Jan 2019

Upon request of the manufacturer, other measurement methods may be approved 1.1. This Appendix defines the method and required instrumentation to determine the REESS current and the REESS voltage of NOVC-HEVs, OVC-HEVs, PEVs and NOVC-FCHVs. 1.2. Measurement of REESS current and REESS voltage shall start at the same time as the test starts and shall end immediately after the vehicle has finished the test. 1.3. The REESS current and the REESS voltage of each phase shall be determined. 1.4. A list of the instrumentation used by the approval authority if they yield equivalent results in accordance with manufacturer to measure REESS voltage and current (including instrument manufacturer, model number, serial number, last calibration dates (where applicable)) during: (a) the Type 1 test according to paragraph 3 of this Sub-Annex, (b) the procedure to determine the correction coefficients according to Appendix 2 of this Sub-Annex (where applicable), (c) the ATCT as specified in Sub-Annex 6a shall be provided to the approval authority. REESS depletion is considered as a negative current. 2.1.1. The REESS current(s) shall be measured during the tests using a clamp-on or closed type current transducer. The current measurement system shall fulfil the requirements specified in Table A8/1 of this Sub-Annex. The equivalence of the candidate method current transducer(s) shall be capable of handling the peak currents at engine starts and temperature conditions at the point of measurement. In order to have an accurate measurement, zero adjustment and degaussing shall be demonstrated to the approval authority. A candidate methodperformed before the test in accordance with the instrument manufacturer's instructions. 2.1.2. Current transducers shall be considered equivalent if the accuracy and the precision is equal to or better than the reference method. The determination of method equivalency fitted to any of the REESS on one of the cables connected directly to the REESS and shall include the total REESS current. In case of shielded wires, appropriate methods shall be based on a correlation study between the candidate and the reference methods. The methods to be used for correlation testing applied in accordance with the approval authority. In order to easily measure the REESS current using external measuring equipment, the manufacturer should provide appropriate, safe and accessible connection points in the vehicle. If that is not feasible, the manufacturer is obliged to support the approval authority in connecting a current transducer to one of the cables directly connected to the REESS in the manner described above in this paragraph. 2.1.3. The current transducer output shall be sampled with a minimum frequency of 20 Hz. The measured current shall be subject to approval by the integrated over time, yielding the measured value of Q, expressed in ampere-hours Ah. The integration may be done in the current measurement system. As an alternative to paragraph 2.1. of this Appendix, the manufacturer may use the on-board current measurement data. The accuracy of these data shall be demonstrated to the approval authority. The basic principle for the determination of accuracy and precision of candidate and reference methods During the tests described in paragraph 3. of this Sub-Annex, the REESS voltage shall be measured with the equipment and accuracy requirements specified in paragraph 1.1. of this Sub-Annex. To measure the REESS voltage using external measuring equipment, the manufacturers shall follow the guidelines in ISO 5725 Part 6 Annex 8 ‘Comparison of alternative Measurement Methods’. Reservedsupport the approval authority by providing REESS voltage measurement points. For NOVC-HEVs, NOVC-FCHVs and OVC-HEVs, instead of using the measured REESS voltage in accordance with paragraph 3.1. of this Appendix, the nominal voltage of the REESS determined in accordance with IEC 60050-482 may be used. As an alternative to paragraph 3.1. and 3.2. of this Appendix, the manufacturer may use the on-board voltage measurement data. The accuracy of these data shall be demonstrated to the approval authority.

  1. 1 Jan 2019 – 1 Sep 2023earlier wording
  2. 1 Jun 2017 – 1 Jan 2019earlier wording