75 Sub-Annex 8 Appendix 2, Regulation (EU) 2017/1151

No longer in force

This Appendix describes the procedure to correct the charge-sustaining Type 1 test CO2 mass emission for NOVC-HEVs and OVC-HEVs, and the fuel consumption for NOVC-FCHVs as a function of the electric energy change of all REESSs.

1.1.1. The phase-specific fuel consumption for NOVC-FCHVs, and the CO2 mass emission for NOVC-HEVs and OVC-HEVs shall be corrected.

1.1.2. In the case that a correction of fuel consumption for NOVC-FCHVs or a correction of CO2 mass emission for NOVC-HEVs and OVC-HEVs measured over the whole cycle according to paragraph 1.1.3. or paragraph 1.1.4. of this Appendix is applied, paragraph 4.3. of this Sub-Annex shall be used to calculate the charge-sustaining REESS energy change ΔEREESS,CS of the charge-sustaining Type 1 test. The considered period j used in paragraph 4.3. of this Sub-Annex is defined by the charge-sustaining Type 1 test.

1.1.3. The correction shall be applied if ΔEREESS,CS is negative which corresponds to REESS discharging and the correction criterion c calculated in paragraph 1.2. of this Appendix is greater than the applicable threshold in accordance with Table A8.App2/1.

1.1.4. The correction may be omitted and uncorrected values may be used if:

(a)

ΔEREESS,CS is positive which corresponds to REESS charging and the correction criterion c calculated in paragraph 1.2. of this Appendix is greater than the applicable threshold in accordance with Table A8.App2/1;

(b)

The correction criterion c calculated in paragraph 1.2. of this Appendix is smaller than the applicable threshold in accordance with Table A8.App2/1;

(c)

The manufacturer can prove to the approval authority by measurement that there is no relation between ΔbREESS,CS and charge-sustaining CO2 mass emission and ΔmREESS,CS and fuel consumption respectively.

1.2.

The correction criterion c is the ratio between the absolute value of the REESS electric energy change ΔEREESS,CS and the fuel energy and shall be calculated as follows:

c

ΔEREESS,CS

Efuel,CS

where:

ΔEREESS,CSis the charge-sustaining REESS energy change according to paragraph 1.1.2. of this Appendix, Wh;

Efuel,CSis the charge-sustaining energy content of the consumed fuel in accordance with paragraph 1.2.1. of this Appendix in the case of NOVC-HEVs and OVC-HEVs, and in accordance with paragraph 1.2.2. of this Appendix in the case of NOVC-FCHVs, Wh.

The charge-sustaining energy content of the consumed fuel for NOVC-HEVs and OVC-HEVs shall be calculated using the following equation:

Efuel,CS10 HV FCCS,nb dCS

where:

Efuel,CSis the charge-sustaining energy content of the consumed fuel of the applicable WLTP test cycle of the charge-sustaining Type 1 test, Wh;

HVis the heating value according to Table A6.App2/1, kWh/l;

FCCS,nbis the non-balanced charge-sustaining fuel consumption of the charge-sustaining Type 1 test, not corrected for the energy balance, determined according to paragraph 6. of Sub-Annex 7, using the gaseous emission compound values according to Table A8/5, step no. 2, l/100 km;

dCSis the distance driven over the corresponding applicable WLTP test cycle, km;

10conversion factor to Wh.

The charge-sustaining energy content of the consumed fuel for NOVC-FCHVs shall be calculated using the following equation:

Efuel,CS10,36 121 FCCS,nb dCS

Efuel,CSis the charge-sustaining energy content of the consumed fuel of the applicable WLTP test cycle of the charge-sustaining Type 1 test, Wh;

121is the lower heating value of hydrogen, MJ/kg;

FCCS,nbis the non-balanced charge-sustaining fuel consumption of the charge-sustaining Type 1 test, not corrected for the energy balance, determined according to Table A8/7, step no.1, kg/100 km;

dCSis the distance driven over the corresponding applicable WLTP test cycle, km;

10,36conversion factor to Wh.

Applicable Type 1 test cycle | Low + Medium | Low + Medium + High | Low + Medium + High + Extra High

Thresholds for correction criterion c | 0,015 | 0,01 | 0,005

2.1.

The CO2 mass emission correction coefficient KCO2, the fuel consumption correction coefficients Kfuel,FCHV, as well as, if required by the manufacturer, the phase-specific correction coefficients KCO2,p and Kfuel,FCHV,p shall be developed based on the applicable charge-sustaining Type 1 test cycles.

In the case that vehicle H was tested for the development of the correction coefficient for CO2 mass emission for NOVC-HEVs and OVC-HEVs, the coefficient may be applied within the interpolation family.

2.2.

The correction coefficients shall be determined from a set of charge-sustaining Type 1 tests according to paragraph 3. of this Appendix. The number of tests performed by the manufacturer shall be equal to or greater than five.

The manufacturer may request to set the state of charge of the REESS prior to the test according to the manufacturer’s recommendation and as described in paragraph 3. of this Appendix. This practice shall only be used for the purpose of achieving a charge-sustaining Type 1 test with opposite sign of the ΔEREESS,CS and with approval of the approval authority.

The set of measurements shall fulfil the following criteria:

(a)

The set shall contain at least one test with ΔEREESS,CS,n ≤ 0 and at least one test with ΔEREESS,CS,n > 0. ΔEREESS,CS,n is the sum of electric energy changes of all REESSs of test n calculated in accordance with paragraph 4.3. of this Sub-Annex.

(b)

The difference in MCO2,CS between the test with the highest negative electric energy change and the test with the highest positive electric energy change shall be greater than or equal to 5 g/km. This criterion shall not be applied for the determination of Kfuel,FCHV.

In the case of the determination of KCO2, the required number of tests may be reduced to three tests if all of the following criteria are fulfilled in addition to (a) and (b):

(c)

the difference in MCO2,CS between any two adjacent measurements, related to the electric energy change during the test, shall be less than or equal to 10 g/km.

(d)

in addition to (b), the test with the highest negative electric energy change and the test with the highest positive electric energy change shall not be within the region that is defined by:

0,01ΔEREESSEfuel 0,01,

where:

Efuelis the energy content of the consumed fuel calculated according to paragraph 1.2. of this Appendix, Wh.

(e)

The difference in MCO2,CS between the test with the highest negative electric energy change and the mid-point, and the difference in MCO2,CS between the mid-point and the test with the highest positive electric energy change shall be similar. The mid-point should preferably be within the range defined by (d). If this requirement is not feasible, the approval authority shall decide if a retest is necessary.

The correction coefficients determined by the manufacturer shall be reviewed and approved by the approval authority prior to its application.

If the set of at least five tests does not fulfil criterion (a) or criterion (b) or both, the manufacturer shall provide evidence to the approval authority as to why the vehicle is not capable of meeting either or both criteria. If the approval authority is not satisfied with the evidence, it may require additional tests to be performed. If the criteria after additional tests are still not fulfilled, the approval authority shall determine a conservative correction coefficient, based on the measurements.

For NOVC-FCHVs, the fuel consumption correction coefficient Kfuel,FCHV, determined by driving a set of charge-sustaining Type 1 tests, is defined using the following equation:

Kfuel,FCHV

nCSn 1 ECDC,CS,n ECDC,CS,avg FCCS,nb,n FCCS,nb,avg

nCSn 1 ECDC,CS,n ECDC,CS,avg 2

where:

Kfuel,FCHVis the fuel consumption correction coefficient, (kg/100 km)/(Wh/km);

ECDC,CS,nis the charge-sustaining electric energy consumption of test n based on the REESS depletion according to the equation below, Wh/km

ECDC,CS,avgis the mean charge-sustaining electric energy consumption of ncs tests based on the REESS depletion according to the equation below, Wh/km;

FCCS,nb,nis the charge-sustaining fuel consumption of test n, not corrected for the energy balance, according to Table A8/7, step no. 1, kg/100 km;

FCCS,nb,avgis the arithmetic average of the charge-sustaining fuel consumption of ncs tests based on the fuel consumption, not corrected for the energy balance, according to the equation below, kg/100 km;

nis the index number of the considered test;

ncsis the total number of tests;

and:

ECDC,CS,avg1ncs

ncs n 1 ECDC,CS,n

and:

FCCS,nb,avg1ncs

ncs n 1 FCCS,nb,n

and:

ECDC,CS,nΔEREESS,CS,ndCS,n

where:

ΔEREESS,CS,nis the charge-sustaining REESS electric energy change of test n according to paragraph 1.1.2. of this Appendix, Wh;

dCS,nis the distance driven over the corresponding charge-sustaining Type 1 test n, km.

The fuel consumption correction coefficient shall be rounded to four significant figures. The statistical significance of the fuel consumption correction coefficient shall be evaluated by the approval authority.

2.3.1.1. It is permitted to apply the fuel consumption correction coefficient that was developed from tests over the whole applicable WLTP test cycle for the correction of each individual phase.

2.3.1.2. Without prejudice to the requirements of paragraph 2.2. of this Appendix, at the manufacturer’s request and upon approval of the approval authority, separate fuel consumption correction coefficients Kfuel,FCHV,p for each individual phase may be developed. In this case, the same criteria as described in paragraph 2.2. of this Appendix shall be fulfilled in each individual phase and the procedure described in paragraph 2.3.1. of this Appendix shall be applied for each individual phase to determine each phase specific correction coefficient.

For OVC-HEVs and NOVC-HEVs, the CO2 mass emission correction coefficient KCO2, determined by driving a set of charge-sustaining Type 1 tests, is defined by the following equation:

KCO2

nCSn 1 ECDC,CS,n ECDC,CS,avg MCO2,CS,nb,n MCO2,CS,nb,avg

nCSn 1 ECDC,CS,n ECDC,CS,avg 2

where:

KCO2is the CO2 mass emission correction coefficient, (g/km)/(Wh/km);

ECDC,CS,nis the charge-sustaining electric energy consumption of test n based on the REESS depletion according to paragraph 2.3.1. of this Appendix, Wh/km;

ECDC,CS,avgis the arithmetic average of the charge-sustaining electric energy consumption of ncs tests based on the REESS depletion according to paragraph 2.3.1. of this Appendix, Wh/km;

MCO2,CS,nb,nis the charge-sustaining CO2 mass emission of test n, not corrected for the energy balance, calculated according Table A8/5, step no. 2, g/km;

MCO2,CS,nb,avgis the arithmetic average of the charge-sustaining CO2 mass emission of ncs tests based on the CO2 mass emission, not corrected for the energy balance, according to the equation below, g/km;

nis the index number of the considered test;

ncsis the total number of tests;

and:

MCO2,CS,nb,avg1nCS

ncs n 1 MCO2,CS,nb,n

The CO2 mass emission correction coefficient shall be rounded to four significant figures. The statistical significance of the CO2 mass emission correction coefficient shall be evaluated by the approval authority.

2.3.2.1. It is permitted to apply the CO2 mass emission correction coefficient developed from tests over the whole applicable WLTP test cycle for the correction of each individual phase.

2.3.2.2. Without prejudice to the requirements of paragraph 2.2. of this Appendix, at the request of the manufacturer upon approval of the approval authority, separate CO2 mass emission correction coefficients KCO2,p for each individual phase may be developed. In this case, the same criteria as described in paragraph 2.2. of this Appendix shall be fulfilled in each individual phase and the procedure described in paragraph 2.3.2. of this Appendix shall be applied for each individual phase to determine phase-specific correction coefficients.

For OVC-HEVs, one of the following test sequences according to Figure A8.App2/1 shall be used to measure all values that are necessary for the determination of the correction coefficients according to paragraph 2. of this Appendix.

Preconditioning and soaking shall be conducted according to paragraph 2.1. of Appendix 4. to this Sub-Annex.

Prior to the test procedure in accordance with paragraph 3.1.1.3. of this Appendix, the manufacturer may adjust the REESS. The manufacturer shall provide evidence that the requirements for the beginning of the test in accordance with paragraph 3.1.1.3. of this Appendix are fulfilled.

3.1.1.3.1. The driver-selectable mode for the applicable WLTP test cycle shall be selected according to paragraph 3. of Appendix 6 to this Sub-Annex.

3.1.1.3.2. For testing, the applicable WLTP test cycle according to paragraph 1.4.2. of this Sub-Annex shall be driven.

3.1.1.3.3. Unless stated otherwise in this Appendix, the vehicle shall be tested according to the Type 1 test procedure described in Sub-Annex 6.

3.1.1.3.4. To obtain a set of applicable WLTP test cycles required for the determination of the correction coefficients, the test may be followed by a number of consecutive sequences required according to paragraph 2.2 of this Appendix consisting of paragraph 3.1.1.1. to paragraph 3.1.1.3. inclusive of this Appendix.

The test vehicle shall be preconditioned according to paragraph 2.1.1. or paragraph 2.1.2. of Appendix 4 to this Sub-Annex.

After preconditioning, soaking according to paragraph 2.1.3. of Appendix 4 to this Sub-Annex shall be omitted and a break, during which the REESS is permitted to be adjusted, shall be set to a maximum duration of 60 minutes. A similar break shall be applied in advance of each test. Immediately after the end of this break, the requirements of paragraph 3.1.2.3. of this Appendix shall be applied.

Upon request of the manufacturer, an additional warm-up procedure may be conducted in advance of the REESS adjustment to ensure similar starting conditions for the correction coefficient determination. If the manufacturer requests this additional warm-up procedure, the identical warm-up procedure shall be applied repeatedly within the test sequence.

3.1.2.3.1. The driver-selectable mode for the applicable WLTP test cycle shall be selected according to paragraph 3. of Appendix 6 to this Sub-Annex.

3.1.2.3.2. For testing, the applicable WLTP test cycle according to paragraph 1.4.2. of this Sub-Annex shall be driven.

3.1.2.3.3. Unless stated otherwise in this Appendix, the vehicle shall be tested according to the Type 1 test procedure described in Sub-Annex 6.

3.1.2.3.4. To obtain a set of applicable WLTP test cycles that are required for the determination of the correction coefficients, the test may be followed by a number of consecutive sequences required according to paragraph 2.2. of this Appendix consisting of paragraphs 3.1.2.2. and 3.1.2.3. of this Appendix.

For NOVC-HEVs and NOVC-FCHVs, one of the following test sequences according to Figure A8.App2/2 shall be used to measure all values that are necessary for the determination of the correction coefficients according to paragraph 2. of this Appendix.

The test vehicle shall be preconditioned and soaked according to paragraph 3.3.1. of this Sub-Annex.

Prior to the test procedure, according to paragraph 3.2.1.3., the manufacturer may adjust the REESS. The manufacturer shall provide evidence that the requirements for the beginning of the test according to paragraph 3.2.1.3. are fulfilled.

3.2.1.3.1. The driver-selectable mode shall be selected according to paragraph 3. of Appendix 6 to this Sub-Annex.

3.2.1.3.2. For testing, the applicable WLTP test cycle according to paragraph 1.4.2. of this Sub-Annex shall be driven.

3.2.1.3.3. Unless stated otherwise in this Appendix, the vehicle shall be tested according to the charge-sustaining Type 1 test procedure described in Sub-Annex 6.

3.2.1.3.4. To obtain a set of applicable WLTP test cycles that are required for the determination of the correction coefficients, the test can be followed by a number of consecutive sequences required according to paragraph 2.2. of this Appendix consisting of paragraph 3.2.1.1. to paragraph 3.2.1.3. inclusive of this Appendix.

The test vehicle shall be preconditioned according to paragraph 3.3.1.1. of this Sub-Annex.

After preconditioning, the soaking according to paragraph 3.3.1.2. of this Sub-Annex shall be omitted and a break, during which the REESS is permitted to be adjusted, shall be set to a maximum duration of 60 minutes. A similar break shall be applied in advance of each test. Immediately after the end of this break, the requirements of paragraph 3.2.2.3. of this Appendix shall be applied.

Upon request of the manufacturer, an additional warm-up procedure may be conducted in advance of the REESS adjustment to ensure similar starting conditions for the correction coefficient determination. If the manufacturer requests this additional warm-up procedure, the identical warm-up procedure shall be applied repeatedly within the test sequence.

3.2.2.3.1. The driver-selectable mode for the applicable WLTP test cycle shall be selected according to paragraph 3. of Appendix 6 to this Sub-Annex.

3.2.2.3.2. For testing, the applicable WLTP test cycle according to paragraph 1.4.2. of this Sub-Annex shall be driven.

3.2.2.3.3. Unless stated otherwise in this Appendix, the vehicle shall be tested according to the Type 1 test procedure described in Sub-Annex 6.

3.2.2.3.4. To get a set of applicable WLTP test cycles that are required for the determination of the correction coefficients, the test can be followed by a number of consecutive sequences required according to paragraph 2.2. of this Appendix consisting of paragraphs 3.2.2.2. and 3.2.2.3. of this Appendix.

Changed on 1 Jan 2019

1.1. Fuel consumption shall be measured using the gravimetric method in accordance with paragraph 2. of this Appendix. At the request of the manufacturer and with approvalThis Appendix describes the procedure to correct the charge-sustaining Type 1 test CO2 mass emission for NOVC-HEVs and OVC-HEVs, and the fuel consumption for NOVC-FCHVs as a function of the approval authority, fuel consumption may be measured using either the pressure method or the flow method. In this case, the manufacturerelectric energy change of all REESSs. 1.1.1. The phase-specific fuel consumption for NOVC-FCHVs, and the CO2 mass emission for NOVC-HEVs and OVC-HEVs shall provide technical evidence that the method yields equivalent results. The pressure and flow methods are described in ISO23828. Fuel consumption shall be calculated by measuring the mass of the fuel tank before and after the test. 2.be corrected. 1.1.2. In the case that a correction of fuel consumption for NOVC-FCHVs or a correction of CO2 mass emission for NOVC-HEVs and OVC-HEVs measured over the whole cycle according to paragraph 1.1.3. or paragraph 1.1. An example of the instrumentation is shown in Figure A8.App7/1. One or more off-vehicle tanks 4. of this Appendix is applied, paragraph 4.3. of this Sub-Annex shall be used to measure the fuel consumption. The off-vehicle tank(s) shall be connected to the vehicle fuel line between the original fuel tank and the fuel cell system. 2.1.2. For preconditioning, the originally installed tank or an external source of hydrogen may be used. 2calculate the charge-sustaining REESS energy change ΔEREESS,CS of the charge-sustaining Type 1 test. The considered period j used in paragraph 4.3. of this Sub-Annex is defined by the charge-sustaining Type 1 test. 1.1.3. The refuelling pressure The correction shall be adjusted to the manufacturer’s recommended value. 2.1.4. Difference of the gas supply pressures in lines shall be minimized when the lines are switched. In the case that influence of pressure difference is expected, the manufacturer and approval authority shall agree whether applied if ΔEREESS,CS is negative which corresponds to REESS discharging and the correction criterion c calculated in paragraph 1.2. of this Appendix is greater than the applicable threshold in accordance with Table A8.App2/1. 1.1.4. The correction may be omitted and uncorrected values may be used if: (a) ΔEREESS,CS is positive which corresponds to REESS charging and the correction is necessary or not. 2.1.5.1. The precision balance used for fuel consumption measurement shall meet the specification of criterion c calculated in paragraph 1.2. of this Appendix is greater than the applicable threshold in accordance with Table A8.App7/1. [Fuel consumption (REESS charge balance = 0) during the test, in mass, standard deviation.] Measurement | Resolution (readability) | Precision (repeatability) Precision balance | 0,1 g maximum | 0,02 maximum 2.1.5.2. The precision balance shall be calibrated in accordance with the specifications provided by the balance manufacturer or at least as often as specified in Table A8.App7/2. Instrument checks | Interval Precision (Repeatability) | Yearly and at major maintenance 2.1.5.3. Appropriate means for reducing the effects of vibration and convection, such as a damping table or a wind barrier, App2/1; (b) The correction criterion c calculated in paragraph 1.2. of this Appendix is smaller than the applicable threshold in accordance with Table A8.App2/1; (c) The manufacturer can prove to the approval authority by measurement that there is no relation between ΔbREESS,CS and charge-sustaining CO2 mass emission and ΔmREESS,CS and fuel consumption respectively. 1.2. The correction criterion c is the ratio between the absolute value of the REESS electric energy change ΔEREESS,CS and the fuel energy and shall be provided.calculated as follows: c ΔEREESS,CS Efuel,CS

1 is the external fuel supply for preconditioning 2 is the pressure regulator 3 is the original tank 4 is the fuel cell system 5 is the precision balance 6 is/are off-vehicle tank(s) for fuel consumption measurement 2.2.1. The mass of the off-vehicle tank shall be measured before the test. 2.2.2. The off-vehicle tank shall be connected to the vehicleΔEREESS,CSis the charge-sustaining REESS energy change according to paragraph 1.1.2. of this Appendix, Wh; Efuel,CSis the charge-sustaining energy content of the consumed fuel line as shown in Figure A8.App7/1. 2.2.3. The test shall be conducted by fuelling from the off-vehicle tank. 2.2.4. The off-vehicle tank shall be removed from the line. in accordance with paragraph 1.2.1. of this Appendix in the case of NOVC-HEVs and OVC-HEVs, and in accordance with paragraph 1.2.2.5. The mass of the tank after the test shall be measured. 2.2.6. The non-balanced of this Appendix in the case of NOVC-FCHVs, Wh. The charge-sustaining fuel consumption FCCS,nb from the measured mass before and after the test energy content of the consumed fuel for NOVC-HEVs and OVC-HEVs shall be calculated using the following equation: FCCS,nbg1 g2d 100Efuel,CS10 HV FCCS,nb dCS

Efuel,CSis the charge-sustaining energy content of the consumed fuel of the applicable WLTP test cycle of the charge-sustaining Type 1 test, Wh; HVis the heating value according to Table A6.App2/1, kWh/l; FCCS,nbis the non-balanced charge-sustaining fuel consumption measured during the of the charge-sustaining Type 1 test, not corrected for the energy balance, determined according to paragraph 6. of Sub-Annex 7, using the gaseous emission compound values according to Table A8/5, step no. 2, l/100 km; dCSis the distance driven over the corresponding applicable WLTP test, kg/100km; g1is the cycle, km; 10conversion factor to Wh. The charge-sustaining energy content of the consumed fuel for NOVC-FCHVs shall be calculated using the following equation: Efuel,CS10,36 121 FCCS,nb dCS Efuel,CSis the charge-sustaining energy content of the consumed fuel of the applicable WLTP test cycle of the charge-sustaining Type 1 test, Wh; 121is the lower heating value of hydrogen, MJ/kg; FCCS,nbis the non-balanced charge-sustaining fuel consumption of the charge-sustaining Type 1 test, not corrected for the energy balance, determined according to Table A8/7, step no.1, kg/100 km; dCSis the distance driven over the corresponding applicable WLTP test cycle, km; 10,36conversion factor to Wh. Applicable Type 1 test cycle | Low + Medium | Low + Medium + High | Low + Medium + High + Extra High Thresholds for correction criterion c | 0,015 | 0,01 | 0,005 2.1. The CO2 mass emission correction coefficient KCO2, the fuel consumption correction coefficients Kfuel,FCHV, as well as, if required by the manufacturer, the phase-specific correction coefficients KCO2,p and Kfuel,FCHV,p shall be developed based on the applicable charge-sustaining Type 1 test cycles. In the case that vehicle H was tested for the development of the tank at the start of correction coefficient for CO2 mass emission for NOVC-HEVs and OVC-HEVs, the coefficient may be applied within the interpolation family. 2.2. The correction coefficients shall be determined from a set of charge-sustaining Type 1 tests according to paragraph 3. of this Appendix. The number of tests performed by the manufacturer shall be equal to or greater than five. The manufacturer may request to set the state of charge of the REESS prior to the test according to the manufacturer’s recommendation and as described in paragraph 3. of this Appendix. This practice shall only be used for the purpose of achieving a charge-sustaining Type 1 test with opposite sign of the ΔEREESS,CS and with approval of the approval authority. The set of measurements shall fulfil the following criteria: (a) The set shall contain at least one test with ΔEREESS,CS,n ≤ 0 and at least one test with ΔEREESS,CS,n > 0. ΔEREESS,CS,n is the sum of electric energy changes of all REESSs of test n calculated in accordance with paragraph 4.3. of this Sub-Annex. (b) The difference in MCO2,CS between the test, kg; g2is the mass of the tank at the end of the with the highest negative electric energy change and the test with the highest positive electric energy change shall be greater than or equal to 5 g/km. This criterion shall not be applied for the determination of Kfuel,FCHV. In the case of the determination of KCO2, the required number of tests may be reduced to three tests if all of the following criteria are fulfilled in addition to (a) and (b): (c) the difference in MCO2,CS between any two adjacent measurements, related to the electric energy change during the test, shall be less than or equal to 10 g/km. (d) in addition to (b), the test with the highest negative electric energy change and the test with the highest positive electric energy change shall not be within the region that is defined by: 0,01ΔEREESSEfuel 0,01, where: Efuelis the energy content of the consumed fuel calculated according to paragraph 1.2. of this Appendix, Wh. (e) The difference in MCO2,CS between the test with the highest negative electric energy change and the mid-point, and the difference in MCO2,CS between the mid-point and the test with the highest positive electric energy change shall be similar. The mid-point should preferably be within the range defined by (d). If this requirement is not feasible, the approval authority shall decide if a retest is necessary. The correction coefficients determined by the manufacturer shall be reviewed and approved by the approval authority prior to its application. If the set of at least five tests does not fulfil criterion (a) or criterion (b) or both, the manufacturer shall provide evidence to the approval authority as to why the vehicle is not capable of meeting either or both criteria. If the approval authority is not satisfied with the evidence, it may require additional tests to be performed. If the criteria after additional tests are still not fulfilled, the approval authority shall determine a conservative correction coefficient, based on the measurements. For NOVC-FCHVs, the fuel consumption correction coefficient Kfuel,FCHV, determined by driving a set of charge-sustaining Type 1 tests, is defined using the following equation: Kfuel,FCHV nCSn 1 ECDC,CS,n ECDC,CS,avg FCCS,nb,n FCCS,nb,avg nCSn 1 ECDC,CS,n ECDC,CS,avg 2 where: Kfuel,FCHVis the fuel consumption correction coefficient, (kg/100 km)/(Wh/km); ECDC,CS,nis the charge-sustaining electric energy consumption of test n based on the REESS depletion according to the equation below, Wh/km ECDC,CS,avgis the mean charge-sustaining electric energy consumption of ncs tests based on the REESS depletion according to the equation below, Wh/km; FCCS,nb,nis the charge-sustaining fuel consumption of test, kg; dis the n, not corrected for the energy balance, according to Table A8/7, step no. 1, kg/100 km; FCCS,nb,avgis the arithmetic average of the charge-sustaining fuel consumption of ncs tests based on the fuel consumption, not corrected for the energy balance, according to the equation below, kg/100 km; nis the index number of the considered test; ncsis the total number of tests; and: ECDC,CS,avg1ncs ncs n 1 ECDC,CS,n and: FCCS,nb,avg1ncs ncs n 1 FCCS,nb,n and: ECDC,CS,nΔEREESS,CS,ndCS,n where: ΔEREESS,CS,nis the charge-sustaining REESS electric energy change of test n according to paragraph 1.1.2. of this Appendix, Wh; dCS,nis the distance driven during the over the corresponding charge-sustaining Type 1 test n, km. FCCS,nb,pThe fuel consumption correction coefficient shall be rounded to four significant figures. The statistical significance of the fuel consumption correction coefficient shall be evaluated by the approval authority. 2.3.1.1. It is permitted to apply the fuel consumption correction coefficient that was developed from tests over the whole applicable WLTP test cycle for the correction of each individual phase. 2.3.1.2. Without prejudice to the requirements of paragraph 2.2. of this Appendix, at the manufacturer’s request and upon approval of the approval authority, separate fuel consumption correction coefficients Kfuel,FCHV,p for each individual phase may be developed. In this case, the same criteria as described in paragraph 2.2. of this Appendix shall be fulfilled in each individual phase and the procedure described in paragraph 2.3.1. of this Appendix shall be applied for each individual phase to determine each phase specific correction coefficient. For OVC-HEVs and NOVC-HEVs, the CO2 mass emission correction coefficient KCO2, determined by driving a set of charge-sustaining Type 1 tests, is defined by the following equation: KCO2 nCSn 1 ECDC,CS,n ECDC,CS,avg MCO2,CS,nb,n MCO2,CS,nb,avg nCSn 1 ECDC,CS,n ECDC,CS,avg 2 where: KCO2is the CO2 mass emission correction coefficient, (g/km)/(Wh/km); ECDC,CS,nis the charge-sustaining electric energy consumption of test n based on the REESS depletion according to paragraph 2.3.1. of this Appendix, Wh/km; ECDC,CS,avgis the arithmetic average of the charge-sustaining electric energy consumption of ncs tests based on the REESS depletion according to paragraph 2.3.1. of this Appendix, Wh/km; MCO2,CS,nb,nis the charge-sustaining CO2 mass emission of test n, not corrected for the energy balance, calculated according Table A8/5, step no. 2, g/km; MCO2,CS,nb,avgis the arithmetic average of the charge-sustaining CO2 mass emission of ncs tests based on the CO2 mass emission, not corrected for the energy balance, according to the equation below, g/km; nis the index number of the considered test; ncsis the total number of tests; and: MCO2,CS,nb,avg1nCS ncs n 1 MCO2,CS,nb,n The CO2 mass emission correction coefficient shall be rounded to four significant figures. The statistical significance of the CO2 mass emission correction coefficient shall be evaluated by the approval authority. 2.3.2.1. It is permitted to apply the CO2 mass emission correction coefficient developed from tests over the whole applicable WLTP test cycle for the correction of each individual phase. 2.3.2.2. Without prejudice to the requirements of paragraph 2.2. of this Appendix, at the request of the manufacturer upon approval of the approval authority, separate CO2 mass emission correction coefficients KCO2,p for each individual phase may be developed. In this case, the same criteria as described in paragraph 2.2. of this Appendix shall be fulfilled in each individual phase and the procedure described in paragraph 2.3.2. of this Appendix shall be applied for each individual phase to determine phase-specific correction coefficients. For OVC-HEVs, one of the following test sequences according to Figure A8.App2/1 shall be used to measure all values that are necessary for the determination of the correction coefficients according to paragraph 2. of this Appendix. Preconditioning and soaking shall be conducted according to paragraph 2.1. of Appendix 4. to this Sub-Annex. Prior to the test procedure in accordance with paragraph 3.1.1.3. of this Appendix, the manufacturer may adjust the REESS. The manufacturer shall provide evidence that the requirements for the beginning of the test in accordance with paragraph 3.1.1.3. of this Appendix are fulfilled. 3.1.1.3.1. The driver-selectable mode for the applicable WLTP test cycle shall be selected according to paragraph 3. of Appendix 6 to this Sub-Annex. 3.1.1.3.2. For testing, the applicable WLTP test cycle according to paragraph 1.4.2. of this Sub-Annex shall be driven. 3.1.1.3.3. Unless stated otherwise in this Appendix, the vehicle shall be tested according to the Type 1 test procedure described in Sub-Annex 6. 3.1.1.3.4. To obtain a set of applicable WLTP test cycles required for the determination of the correction coefficients, the test may be followed by a number of consecutive sequences required according to paragraph 2.2 of this Appendix consisting of paragraph 3.1.1.1. to paragraph 3.1.1.3. inclusive of this Appendix. The test vehicle shall be preconditioned according to paragraph 2.1.1. or paragraph 2.1.2. of Appendix 4 to this Sub-Annex. After preconditioning, soaking according to paragraph 2.1.3. of Appendix 4 to this Sub-Annex shall be omitted and a break, during which the REESS is permitted to be adjusted, shall be set to a maximum duration of 60 minutes. A similar break shall be applied in advance of each test. Immediately after the end of this break, the requirements of paragraph 3.1.2.3. of this Appendix shall be applied. Upon request of the manufacturer, an additional warm-up procedure may be conducted in advance of the REESS adjustment to ensure similar starting conditions for the correction coefficient determination. If the manufacturer requests this additional warm-up procedure, the identical warm-up procedure shall be applied repeatedly within the test sequence. 3.1.2.3.1. The driver-selectable mode for the applicable WLTP test cycle shall be selected according to paragraph 3. of Appendix 6 to this Sub-Annex. 3.1.2.3.2. For testing, the applicable WLTP test cycle according to paragraph 1.4.2. of this Sub-Annex shall be driven. 3.1.2.3.3. Unless stated otherwise in this Appendix, the vehicle shall be tested according to the Type 1 test procedure described in Sub-Annex 6. 3.1.2.3.4. To obtain a set of applicable WLTP test cycles that are required for the determination of the correction coefficients, the test may be followed by a number of consecutive sequences required according to paragraph 2.2. of this Appendix consisting of paragraphs 3.1.2.2. and 3.1.2.3. of this Appendix. For NOVC-HEVs and NOVC-FCHVs, one of the following test sequences according to Figure A8.App2/2 shall be used to measure all values that are necessary for the determination of the correction coefficients according to paragraph 2. of this Appendix. The test vehicle shall be preconditioned and soaked according to paragraph 3.3.1. of this Sub-Annex. Prior to the test procedure, according to paragraph 3.2.1.3., the manufacturer may adjust the REESS. The manufacturer shall provide evidence that the requirements for the beginning of the test according to paragraph 3.2.1.3. are fulfilled. 3.2.1.3.1. The driver-selectable mode shall be selected according to paragraph 3. of Appendix 6 to this Sub-Annex. 3.2.1.3.2. For testing, the applicable WLTP test cycle according to paragraph 1.4.2. of this Sub-Annex shall be driven. 3.2.1.3.3. Unless stated otherwise in this Appendix, the vehicle shall be tested according to the charge-sustaining Type 1 test procedure described in Sub-Annex 6. 3.2.1.3.4. To obtain a set of applicable WLTP test cycles that are required for the determination of the correction coefficients, the test can be followed by a number of consecutive sequences required according to paragraph 2.2. of this Appendix consisting of paragraph 3.2.1.1. to paragraph 3.2.1.3. inclusive of this Appendix. The test vehicle shall be preconditioned according to paragraph 3.3.1.1. of this Sub-Annex. After preconditioning, the soaking according to paragraph 3.3.1.2. of this Sub-Annex shall be omitted and a break, during which the REESS is permitted to be adjusted, shall be set to a maximum duration of 60 minutes. A similar break shall be applied in advance of each test. Immediately after the end of this break, the requirements of paragraph 3.2.2.3. of this Appendix shall be applied. Upon request of the manufacturer, an additional warm-up procedure may be conducted in advance of the REESS adjustment to ensure similar starting conditions for the correction coefficient determination. If the manufacturer requests this additional warm-up procedure, the identical warm-up procedure shall be applied repeatedly within the test sequence. 3.2.2.3.1. The driver-selectable mode for the applicable WLTP test cycle shall be selected according to paragraph 3. of Appendix 6 to this Sub-Annex. 3.2.2.3.2. For testing, the applicable WLTP test cycle according to paragraph 1.4.2. of this Sub-Annex shall be driven. 3.2.2.3.3. Unless stated otherwise in this Appendix, the vehicle shall be tested according to the Type 1 test procedure described in Sub-Annex 6. 3.2.2.3.4. To get a set of applicable WLTP test cycles that are required for the determination of the correction coefficients, the test can be followed by a number of consecutive sequences required according to paragraph 2.2. of this Appendix consisting of paragraphs 3.2.2.2. and 3.2.2.3. of this Appendix.

  1. 1 Jan 2019 – 1 Sep 2023earlier wording
  2. 27 Jul 2017 – 1 Jan 2019earlier wording
  3. 1 Jun 2017 – 27 Jul 2017earlier wording