25 Appendix 4, Regulation (EU) 2017/1151

No longer in force

This Appendix describes the procedure to determine the instantaneous mass and particle number emissions [g/s; #/s] that shall be used for the subsequent evaluation of an RDE trip and the calculation of the final emission result as described in Appendix 6.

%per cent

<smaller than

#/snumber per second

αmolar hydrogen ratio (H/C)

βmolar carbon ratio (C/C)

γmolar sulphur ratio (S/C)

δmolar nitrogen ratio (N/C)

Δtt,itransformation time t of the analyser [s]

Δtt,mtransformation time t of the exhaust mass flow meter [s]

εmolar oxygen ratio (O/C)

ρedensity of the exhaust

ρgasdensity of the exhaust component ‘gas’

λexcess air ratio

λiinstantaneous excess air ratio

A/Fststoichiometric air-to-fuel ratio [kg/kg]

°Cdegrees centigrade

cCH4concentration of methane

cCOdry CO concentration [%]

cCO2dry CO2 concentration [%]

cdrydry concentration of a pollutant in ppm or per cent volume

cgas,iinstantaneous concentration of the exhaust component ‘gas’ [ppm]

cHCwwet HC concentration [ppm]

cHC(w/NMC)HC concentration with CH4 or C2H6 flowing through the NMC [ppmC1]

cHC(w/oNMC)HC concentration with CH4 or C2H6 bypassing the NMC [ppmC1]

ci,ctime-corrected concentration of component i [ppm]

ci,rconcentration of component i [ppm] in the exhaust

cNMHCconcentration of non-methane hydrocarbons

cwetwet concentration of a pollutant in ppm or per cent volume

EEethane efficiency

EMmethane efficiency

ggramme

g/sgramme per second

Haintake air humidity [g water per kg dry air]

inumber of the measurement

kgkilogramme

kg/hkilogramme per hour

kg/skilogramme per second

kwdry-wet correction factor

mmetre

mgas,imass of the exhaust component ‘gas’ [g/s]

qmaw,iinstantaneous intake air mass flow rate [kg/s]

qm,ctime-corrected exhaust mass flow rate [kg/s]

qmew,iinstantaneous exhaust mass flow rate [kg/s]

qmf,iinstantaneous fuel mass flow rate [kg/s]

qm,rraw exhaust mass flow rate [kg/s]

rcross-correlation coefficient

r2coefficient of determination

rhhydrocarbon response factor

rpmrevolutions per minute

ssecond

ugasu value of the exhaust component ‘gas’

For the correct calculation of distance-specific emissions, the recorded traces of component concentrations, exhaust mass flow rate, vehicle speed, and other vehicle data shall be time corrected. To facilitate the time correction, data which are subject to time alignment shall be recorded either in a single data recording device or with a synchronised timestamp following point 5.1 of Appendix 1. The time correction and alignment of parameters shall be carried out by following the sequence described in points 3.1 to 3.3.

The recorded traces of all component concentrations shall be time corrected by reverse shifting according to the transformation times of the respective analysers. The transformation time of analysers shall be determined according to point 4.4 of Appendix 2:

ci,c t Δtt,ici,r t

where:

ci,cis the time-corrected concentration of component i as function of time t

ci,ris the raw concentration of component i as function of time t

Δtt,iis the transformation time t of the analyser measuring component i

The exhaust mass flow rate measured with an exhaust flow meter shall be time corrected by reverse shifting according to the transformation time of the exhaust mass flow meter. The transformation time of the mass flow meter shall be determined according to point 4.4. of Appendix 2:

qm,c t Δtt,mqm,r t

where:

qm,cis the time-corrected exhaust mass flow rate as function of time t

qm,ris the raw exhaust mass flow rate as function of time t

Δtt,mis the transformation time t of the exhaust mass flow meter

In case the exhaust mass flow rate is determined by ECU data or a sensor, an additional transformation time shall be considered and obtained by cross-correlation between the calculated exhaust mass flow rate and the exhaust mass flow rate measured following point 4 of Appendix 3.

Other data obtained from a sensor or the ECU shall be time-aligned by cross-correlation with suitable emission data (e.g., component concentrations).

To time align vehicle speed with the exhaust mass flow rate, it is first necessary to establish one valid speed trace. In case vehicle speed is obtained from multiple sources (e.g., the GPS, a sensor or the ECU), the speed values shall be time aligned by cross-correlation.

Vehicle speed shall be time aligned with the exhaust mass flow rate by cross-correlation between the exhaust mass flow rate and the product of vehicle speed and positive acceleration.

The time alignment of signals whose values change slowly and within a small value range, e.g. ambient temperature, can be omitted.

Cold start for the purposes of RDE is the period from the test start until the point when the vehicle has run for 5 minutes. If the coolant temperature is determined, the cold start period ends once the coolant is at least 70 °C for the first time but no later than 5 minutes after test start.

Any instantaneous emissions or exhaust flow measurements obtained while the combustion engine is deactivated shall be recorded. In a separate step, the recorded values shall afterward be set to zero by the data post processing. The combustion engine shall be considered as deactivated if two of the following criteria apply: the recorded engine speed is < 50 rpm; the exhaust mass flow rate is measured at < 3 kg/h; the measured exhaust mass flow rate drops to < 15 % of the typical steady-state exhaust mass flow rate at idling.

In case well-reasoned doubts exist that a trip has been conducted above of the permissible altitude as specified in point 5.2 of this Annex and in case altitude has only been measured with a GPS, the GPS altitude data shall be checked for consistency and, if necessary, corrected. The consistency of data shall be checked by comparing the latitude, longitude and altitude data obtained from the GPS with the altitude indicated by a digital terrain model or a topographic map of suitable scale. Measurements that deviate by more than 40 m from the altitude depicted in the topographic map shall be manually corrected and marked.

The vehicle speed as determined by the GPS shall be checked for consistency by calculating and comparing the total trip distance with reference measurements obtained from either a sensor, the validated ECU or, alternatively, from a digital road network or topographic map. It is mandatory to correct GPS data for obvious errors, e.g., by applying a dead reckoning sensor, prior to the consistency check. The original and uncorrected data file shall be retained and any corrected data shall be marked. The corrected data shall not exceed an uninterrupted time period of 120 s or a total of 300 s. The total trip distance as calculated from the corrected GPS data shall deviate by no more than 4 % from the reference. If the GPS data do not meet these requirements and no other reliable speed source is available, the test results shall be voided.

If the emissions are measured on a dry basis, the measured concentrations shall be converted to a wet basis as:

where:

cwetkw cdry

cwetis the wet concentration of a pollutant in ppm or per cent volume

cdryis the dry concentration of a pollutant in ppm or per cent volume

kwis the dry-wet correction factor

The following equation shall be used to calculate kw:

kw11 α 0,005 cco2 cco kw1 1,008

where:

kw11,608 Ha

1000 1,608 Ha

where:

Hais the intake air humidity [g water per kg dry air]

cCO2is the dry CO2 concentration [%]

cCOis the dry CO concentration [%]

αis the molar hydrogen ratio

NOx emissions shall not be corrected for ambient temperature and humidity.

Negative intermediate results shall not be corrected. Negative final results shall be set to zero.

The second-by second emissions calculated in accordance with this Appendix may be divided by a value of 1,6 solely for the cases laid down in points 9.5 and 9.6.

The corrective factor of 1,6 shall be applied only once. The corrective factor of 1,6 applies to pollutant emissions but not to CO2.

The components in the raw exhaust shall be measured with the measurement and sampling analysers described in Appendix 2. The raw concentrations of relevant components shall be measured in accordance with Appendix 1. The data shall be time corrected and aligned in accordance with point 3.

For methane measurement using a NMC-FID, the calculation of NMHC depends on the calibration gas/method used for the zero/span calibration adjustment. When a FID is used for THC measurement without a NMC, it shall be calibrated with propane/air or propane/N2 in the normal manner. For the calibration of the FID in series with a NMC, the following methods are permitted:

(a)

the calibration gas consisting of propane/air bypasses the NMC;

(b)

the calibration gas consisting of methane/air passes through the NMC.

It is strongly recommended to calibrate the methane FID with methane/air through the NMC.

In method (a), the concentrations of CH4 and NMHC shall be calculated as follows:

cCH4cHCw oNMC 1 EM cHCwNMC

EE EM

cNMHCcHCw NMC cHCw oNMC 1 EErh EE EM

In method (b), the concentration of CH4 and NMHC shall be calculated as follows:

cCH4cHCw NMC rh 1 EM cHCw oNMC 1 EE

rh EE EM

cNMHCcHCw oNMC 1 EM cHCw NMC rh 1 EM

EE EM

where:

cHC(w/oNMC)is the HC concentration with CH4 or C2H6 bypassing the NMC [ppmC1]

cHC(w/NMC)is the HC concentration with CH4 or C2H6 flowing through the NMC [ppmC1]

rhis the hydrocarbon response factor as determined in point 4.3.3.(b) of Appendix 2

EMis the methane efficiency as determined in point 4.3.4.(a) of Appendix 2

EEis the ethane efficiency as determined in point 4.3.4(b) of Appendix 2

If the methane FID is calibrated through the cutter (method b), then the methane conversion efficiency as determined in point 4.3.4.(a) of Appendix 2 is zero. The density used for calculating the NMHC mass shall be equal to that of total hydrocarbons at 273,15 K and 101,325 kPa and is fuel-dependent.

The calculation of instantaneous mass emissions according to points 11 and 12 requires determining the exhaust mass flow rate. The exhaust mass flow rate shall be determined by one of the direct measurement methods specified in point 7.2 of Appendix 2. Alternatively, it is permissible to calculate the exhaust mass flow rate as described in points 10.2 to 10.4.

The instantaneous exhaust mass flow rate can be calculated from the air mass flow rate and the fuel mass flow rate as follows:

qmew,iqmaw,i qmf,i

where:

qmew,iis the instantaneous exhaust mass flow rate [kg/s]

qmaw,iis the instantaneous intake air mass flow rate [kg/s]

qmf,iis the instantaneous fuel mass flow rate [kg/s]

If the air mass flow rate and the fuel mass flow rate or the exhaust mass flow rate are determined from ECU recording, the calculated instantaneous exhaust mass flow rate shall meet the linearity requirements specified for the exhaust mass flow rate in point 3 of Appendix 2 and the validation requirements specified in point 4.3 of Appendix 3.

The instantaneous exhaust mass flow rate can be calculated from the air mass flow rate and the air-to-fuel ratio as follows:

qmew,i qmaw,i 1 1AFst λi

where:

AFst138,0 1 α4 ε2 γ12,011 1,008 α 15,9994 ε 14,0067 δ 32,0675 γλi

100 cCO 10 42 cHCw 10 4 α4 1 2 cCO 10 43,5 cCO21 cCO 10 43,5 cCO2 ε2 δ2 cCO2 cCO 10 4

4,764 1 α4 ε2 γ cCO2 cCO 10 4 cHCw 10 4

where:

qmaw,iis the instantaneous intake air mass flow rate [kg/s]

A/Fstis the stoichiometric air-to-fuel ratio [kg/kg]

λiis the instantaneous excess air ratio

cCO2is the dry CO2 concentration [%]

cCOis the dry CO concentration [ppm]

cHCwis the wet HC concentration [ppm]

αis the molar hydrogen ratio (H/C)

βis the molar carbon ratio (C/C)

γis the molar sulphur ratio (S/C)

δis the molar nitrogen ratio (N/C)

εis the molar oxygen ratio (O/C)

Coefficients refer to a fuel Cβ Hα Oε Nδ Sγ with β = 1 for carbon based fuels. The concentration of HC emissions is typically low and may be omitted when calculating λi.

If the air mass flow rate and air-to-fuel ratio are determined from ECU recording, the calculated instantaneous exhaust mass flow rate shall meet the linearity requirements specified for the exhaust mass flow rate in point 3 of Appendix 2 and the validation requirements specified in point 4.3 of Appendix 3.

The instantaneous exhaust mass flow rate can be calculated from the fuel flow and the air-to-fuel ratio (calculated with A/Fst and λi according to point 10.3) as follows:

qmew,i qmf,i 1 AFst λi

The calculated instantaneous exhaust mass flow rate shall meet the linearity requirements specified for the exhaust gas mass flow rate in point 3 of Appendix 2 and the validation requirements specified in point 4.3 of Appendix 3.

The instantaneous mass emissions [g/s] shall be determined by multiplying the instantaneous concentration of the pollutant under consideration [ppm] with the instantaneous exhaust mass flow rate [kg/s], both corrected and aligned for the transformation time, and the respective u value of Table 1. If measured on a dry basis, the dry-wet correction according to point 8.1 shall be applied to the instantaneous component concentrations before executing any further calculations. If occurring, negative instantaneous emission values shall enter all subsequent data evaluations. Parameter values shall enter the calculation of instantaneous emissions [g/s] as reported by the analyser, flow-measuring instrument, sensor or the ECU. The following equation shall be applied:

where:

mgas,iugas cgas,i qmew,i

mgas,iis the mass of the exhaust component ‘gas’ [g/s]

ugasis the ratio of the density of the exhaust component ‘gas’ and the overall density of the exhaust as listed in Table 1

cgas,iis the measured concentration of the exhaust component ‘gas’ in the exhaust [ppm]

qmew,iis the measured exhaust mass flow rate [kg/s]

gasis the respective component

inumber of the measurement

[depending on fuel] [at λ = 2, dry air, 273 K, 101.3 kPa] [u values accurate within 0,2 % for mass composition of: C=66-76 %; H=22-25 %; N=0-12 %] [NMHC on the basis of CH2.93 (for THC the ugas coefficient of CH4 shall be used)] [u accurate within 0,2 % for mass composition of: C3=70-90 %; C4=10-30 %] [ugas is a unitless parameter; the ugas values include unit conversions to ensure that the instantaneous emissions are obtained in the specified physical unit, i.e., g/s]

Fuel | ρe [kg/m3] | Component or pollutant i

NOx | CO | HC | CO2 | O2 | CH4

ρgas [kg/m3]

2,053 | 1,250 | | 1,9636 | 1,4277 | 0,716

ugas,

Diesel (B7) | 1,2943 | 0,001586 | 0,000966 | 0,000482 | 0,001517 | 0,001103 | 0,000553

Ethanol (ED95) | 1,2768 | 0,001609 | 0,000980 | 0,000780 | 0,001539 | 0,001119 | 0,000561

CNG | 1,2661 | 0,001621 | 0,000987 | 0,000528 | 0,001551 | 0,001128 | 0,000565

Propane | 1,2805 | 0,001603 | 0,000976 | 0,000512 | 0,001533 | 0,001115 | 0,000559

Butane | 1,2832 | 0,001600 | 0,000974 | 0,000505 | 0,001530 | 0,001113 | 0,000558

LPG | 1,2811 | 0,001602 | 0,000976 | 0,000510 | 0,001533 | 0,001115 | 0,000559

Petrol (E10) | 1,2931 | 0,001587 | 0,000966 | 0,000499 | 0,001518 | 0,001104 | 0,000553

Ethanol (E85) | 1,2797 | 0,001604 | 0,000977 | 0,000730 | 0,001534 | 0,001116 | 0,000559

The instantaneous particle number emissions [particles/s] shall be determined by multiplying the instantaneous concentration of the pollutant under consideration [particles/cm3] with the instantaneous exhaust mass flow rate [kg/s], both corrected and aligned for the transformation time. If applicable, negative instantaneous emission values shall enter all subsequent data evaluations. All significant digits of intermediate results shall enter the calculation of the instantaneous emissions. The following equation shall apply:

PN,icPN,iqmew,iρe

where:

PN,iis the particle number flux [particles/s]

cPN,iis the measured particle number concentration [#/m3] normalized at 0 °C

qmew,iis the measured exhaust mass flow rate [kg/s]

ρeis the density of the exhaust gas [kg/m3] at 0 °C (Table 1)

The data shall be exchanged between the measurement systems and the data evaluation software by a standardised reporting file as specified in point 2 of Appendix 8. Any pre-processing of data (e.g. time correction according to point 3 or the correction of the GPS vehicle speed signal according to point 7) shall be done with the control software of the measurement systems and shall be completed before the data reporting file is generated. If data are corrected or processed prior to entering the data reporting file, the original raw data shall be kept for quality assurance and control. Rounding of intermediate values is not permitted.

Changed on 1 Jan 2019

This Appendix describes the data evaluation according to the power binning method, named in this appendix ‘evaluation by normalisation to a standardised power frequency (SPF) distribution’ aref …Reference acceleration for Pdrive DWLTC…intercept procedure to determine the instantaneous mass and particle number emissions [g/s; #/s] that shall be used for the subsequent evaluation of an RDE trip and the calculation of the Veline from WLTC f0, f1, f2…Driving resistance coefficients [N], [N/(km/h)], [N/(km/h)2] i…Time step for instantaneous measurements, minimum resolution 1Hz j…Wheel power class, j=1 to 9 k…Time step for the 3 second moving average values kWLTC…Slopefinal emission result as described in Appendix 6. %per cent <smaller than #/snumber per second αmolar hydrogen ratio (H/C) βmolar carbon ratio (C/C) γmolar sulphur ratio (S/C) δmolar nitrogen ratio (N/C) Δtt,itransformation time t of the Veline from WLTC mgas, i…Instantaneous massanalyser [s] Δtt,mtransformation time t of the exhaust component ‘gas’ at time step i, [g/s]; for PN in [#/s] mgas, 3s, k…3 second moving average mass flow mass flow meter [s] εmolar oxygen ratio (O/C) ρedensity of the exhaust ρgasdensity of the exhaust gas component ‘gas’ in time step k given in 1 Hz resolution [g/s]; for PN in [#/s] mgas,j…Average emission value of an exhaust gas component in the wheel power class j, [g/s]; for PN in [#/s] mgas,U…Weighted emission value of an λexcess air ratio λiinstantaneous excess air ratio A/Fststoichiometric air-to-fuel ratio [kg/kg] °Cdegrees centigrade cCH4concentration of methane cCOdry CO concentration [%] cCO2dry CO2 concentration [%] cdrydry concentration of a pollutant in ppm or per cent volume cgas,iinstantaneous concentration of the exhaust gas component ‘gas’ for the subsample of all seconds i [ppm] cHCwwet HC concentration [ppm] cHC(w/NMC)HC concentration with vi < 60 km/h, [g/s]; for PN in [#/s] Mw gas,d…Weighted distance-specific emissions for the exhaust gas component ‘gas’ for the entire trip, [g/km]; for PN in [#/km] Mw PN,d…Weighted distance-specific emissions for the exhaust gas component ‘PN’ for the entire trip, [#/km] Mw,gas,d,U…Weighted distance-specific emissions for the exhaust gas component ‘gas’ for the subsample of all seconds i with vi < 60 km/h, [g/km] Mw,PN,d,U…Weighted distance-specific emissions for CH4 or C2H6 flowing through the NMC [ppmC1] cHC(w/oNMC)HC concentration with CH4 or C2H6 bypassing the NMC [ppmC1] ci,ctime-corrected concentration of component i [ppm] ci,rconcentration of component i [ppm] in the exhaust cNMHCconcentration of non-methane hydrocarbons cwetwet concentration of a pollutant in ppm or per cent volume EEethane efficiency EMmethane efficiency ggramme g/sgramme per second Haintake air humidity [g water per kg dry air] inumber of the measurement kgkilogramme kg/hkilogramme per hour kg/skilogramme per second kwdry-wet correction factor mmetre mgas,imass of the exhaust gas component ‘PN’ for the subsample of all seconds i with vi < 60 km/h, [#/km] p…Phase of WLTC (low, medium, high and extra-high), p=1-4 Pdrag…Engine drag power in the Veline approach where fuel injection is zero, [kW] Prated…Maximum rated engine power as declared by the manufacturer, [kW] Prequired,i…Power to overcome road load and inertia of a vehicle at time step i, [kW] Pr,,i…Same as Prequired,i defined above used in longer equations Pwot(nnorm)…Full load power curve, [kW] Pc,j…Wheel power class limits for class number j, [kW] (Pc,j, lower bound represents the lower limit Pc,j, upper bound the upper limit) Pc,norm, j…Wheel power class limits for class j as normalised power value, [-] Pr, i…Power demand at the vehicles wheel hubs to overcome driving resistances in time step i [kW] Pw,3s,k…3 second moving average power demand at the vehicles wheel hubs to overcome driving resistances in ingas’ [g/s] qmaw,iinstantaneous intake air mass flow rate [kg/s] qm,ctime-corrected exhaust mass flow rate [kg/s] qmew,iinstantaneous exhaust mass flow rate [kg/s] qmf,iinstantaneous fuel mass flow rate [kg/s] qm,rraw exhaust mass flow rate [kg/s] rcross-correlation coefficient r2coefficient of determination rhhydrocarbon response factor rpmrevolutions per minute ssecond ugasu value of the exhaust component ‘gas’ For the correct calculation of distance-specific emissions, the recorded traces of component concentrations, exhaust mass flow rate, vehicle speed, and other vehicle data shall be time corrected. To facilitate the time correction, data which are subject to time alignment shall be recorded either in a single data recording device or with a synchronised timestamp following point 5.1 of Appendix 1. The time step k in 1 Hz resolution [kW] Pdrive…Power demand at the wheel hubs for a vehicle at reference speed and acceleration [kW] Pnorm…Normalised power demand at the wheel hubs [-] ti…Total correction and alignment of parameters shall be carried out by following the sequence described in points 3.1 to 3.3. The recorded traces of all component concentrations shall be time in step i, [s] tc,j…Time share of the wheel power class j, [%] ts…Start time corrected by reverse shifting according to the transformation times of the WLTC phase p, [s] te…endrespective analysers. The transformation time of the WLTC phase p, [s] TM …Test mass of the vehicle SPF…Standardised Power Frequency distribution vi…Actual vehicle speed in time step i, [km/h] vj…Average vehicle speed in the wheel power class j, km/h vref …Reference velocity for Pdrive v3s,k…3 seconds moving average analysers shall be determined according to point 4.4 of Appendix 2: ci,c t Δtt,ici,r t where: ci,cis the time-corrected concentration of component i as function of time t ci,ris the raw concentration of component i as function of time t Δtt,iis the transformation time t of the vehicle velocity in time step k, [km/h] vU…Weighted vehicle speed in the wheel power class j, [km/h] The power binning method uses the instantaneous emissionsanalyser measuring component i The exhaust mass flow rate measured with an exhaust flow meter shall be time corrected by reverse shifting according to the transformation time of the pollutants, mgas, i (g/s) calculated in accordance with Appendix 4. The mgas, i values exhaust mass flow meter. The transformation time of the mass flow meter shall be classified in accordance with the corresponding power at the wheels and the classified average emissions per power class shall be weighted to obtain the emission values for a test with a normal power distribution according to the following points. The actual wheel power Pr,i shall be the total power to overcome air resistance, rolling resistance, road gradients, longitudinal inertia of the vehicle and rotational inertia of the wheels. When measured and recorded, the wheel power signal shall use a torque signal meeting the linearity requirements laid down in determined according to point 4.4. of Appendix 2: qm,c t Δtt,mqm,r t where: qm,cis the time-corrected exhaust mass flow rate as function of time t qm,ris the raw exhaust mass flow rate as function of time t Δtt,mis the transformation time t of the exhaust mass flow meter In case the exhaust mass flow rate is determined by ECU data or a sensor, an additional transformation time shall be considered and obtained by cross-correlation between the calculated exhaust mass flow rate and the exhaust mass flow rate measured following point 4 of Appendix 2, point 3.2. The reference point for measurement are the wheel hubs of the driven wheels. As an alternative, the actual wheel power may be determined from the instantaneous CO2 emissions following the procedure laid down in point 4 of this Appendix. The provisions of this Appendix 6 shall only be applicable for NOVC-HEVs (as defined in point 1.2.40) if the power at the wheels has been determined by wheel hub torque measurements. Three second moving averages 3. Other data obtained from a sensor or the ECU shall be time-aligned by cross-correlation with suitable emission data (e.g., component concentrations). To time align vehicle speed with the exhaust mass flow rate, it is first necessary to establish one valid speed trace. In case vehicle speed is obtained from multiple sources (e.g., the GPS, a sensor or the ECU), the speed values shall be time aligned by cross-correlation. Vehicle speed shall be calculated from all relevant instantaneous test data to reduce influences of possibly imperfect time alignment between emission mass flow and wheel power. The moving average time aligned with the exhaust mass flow rate by cross-correlation between the exhaust mass flow rate and the product of vehicle speed and positive acceleration. The time alignment of signals whose values shall be computed in a 1 Hz frequency: mgas,3s,k k 2i kmgas,i3 Pw,3s,k k 2i kPw,i3 ν3s,k k 2i kνi3 Where ktime step for moving average values itime step change slowly and within a small value range, e.g. ambient temperature, can be omitted. Cold start for the purposes of RDE is the period from instantaneousthe test data The standard power frequencies are defined for urban driving and for the total trip (see paragraph 3.4) and a separate evaluation of the emissions shall be made for the total trip andstart until the point when the vehicle has run for 5 minutes. If the coolant temperature is determined, the cold start period ends once the coolant is at least 70 °C for the urban part. For thefirst time but no later evaluation of the urban part of the trip, the three second moving averages calculated according to paragraph 3.2 than 5 minutes after test start. Any instantaneous emissions or exhaust flow measurements obtained while the combustion engine is deactivated shall be allocated to urban driving conditions according to the three second moving average of the velocity signal (v3s,k) following the speed range defined in Table 1-1. The sample for the total trip evaluation shall cover allrecorded. In a separate step, the recorded values shall afterward be set to zero by the data post processing. The combustion engine shall be considered as deactivated if two of the following criteria apply: the recorded engine speed ranges including also the urban part. [not used in the actual regulatory evaluation of urban driving] Vehicle category | | Urban | Rural | Motorway M1, M2, N1 | vi [km/h] | 0 to ≤ 60 | > 60 to ≤ 90 | > 90 N2 | vi [km/h] | 0 to ≤ 60 | > 60 to ≤ 80 | > 80 3.4.1. The power classes and the corresponding time shares of the power classes in normal driving are defined for normalised power values to be representative for any LDV (Table 1-2). Power class No | Pc,norm,j [-] | Urban | Total trip From > | to ≤ | Time share, tC,j 1 | | – 0,1 | 21,9700 % | 18,5611 % 2 | – 0,1 | 0,1 | 28,7900 % | 21,8580 % 3 | 0,1 | 1 | 44,0000 % | 43,4582 % 4 | 1 | 1,9 | 4,7400 % | 13,2690 % 5 | 1,9 | 2,8 | 0,4500 % | 2,3767 % 6 | 2,8 | 3,7 | 0,0450 % | 0,4232 % 7 | 3,7 | 4,6 | 0,0040 % | 0,0511 % 8 | 4,6 | 5,5 | 0,0004 % | 0,0024 % 9 | 5,5 | | 0,0003 % | 0,0003 % The Pc,norm columns in Table 1-2is < 50 rpm; the exhaust mass flow rate is measured at < 3 kg/h; the measured exhaust mass flow rate drops to < 15 % of the typical steady-state exhaust mass flow rate at idling. In case well-reasoned doubts exist that a trip has been conducted above of the permissible altitude as specified in point 5.2 of this Annex and in case altitude has only been measured with a GPS, the GPS altitude data shall be checked for consistency and, if necessary, corrected. The consistency of data shall be checked by comparing the latitude, longitude and altitude data obtained from the GPS with the altitude indicated by a digital terrain model or a topographic map of suitable scale. Measurements that deviate by more than 40 m from the altitude depicted in the topographic map shall be manually corrected and marked. The vehicle speed as determined by the GPS shall be checked for consistency by calculating and comparing the total trip distance with reference measurements obtained from either a sensor, the validated ECU or, alternatively, from a digital road network or topographic map. It is mandatory to correct GPS data for obvious errors, e.g., by applying a dead reckoning sensor, prior to the consistency check. The original and uncorrected data file shall be de-normalised by multiplication with Pdrive, where Pdrive is the actual wheel power of the tested car in the type approval settings at the chassis dynamometer at vref and aref. Pc,j [kW] = Pc,norm, j * Pdrive Pdrive νref 3,6f0f1νreff2νref2TMWLTPαref0,001 Where: j is the power class index according to Table 1 νref = 66 km/h αref = 0,44 m/s2 The driving resistance coefficients f0, f1, f2 are the target WLTP road load values for the individual vehicle to be PEMS tested, as defined in point 2.4 of sub-Annex 4 of Annex XXI TMWLTP is the WLTP test mass of the individual vehicle to be PEMS tested, as defined in point 3.2.25 of Annex XXI. The maximum wheel power class to be considered is the highest class in Table 1 which includes (Prated × 0,9). The time shares of all excluded classesretained and any corrected data shall be marked. The corrected data shall not exceed an uninterrupted time period of 120 s or a total of 300 s. The total trip distance as calculated from the corrected GPS data shall deviate by no more than 4 % from the reference. If the GPS data do not meet these requirements and no other reliable speed source is available, the test results shall be voided. If the emissions are measured on a dry basis, the measured concentrations shall be converted to a wet basis as: where: cwetkw cdry cwetis the wet concentration of a pollutant in ppm or per cent volume cdryis the dry concentration of a pollutant in ppm or per cent volume kwis the dry-wet correction factor The following equation shall be added to the highest remaining class. From each Pc,norm,j the corresponding Pc,j shall be calculated to define the upper and lower bounds in kW per wheel power class for the tested vehicle as shown in Figure 1. An example for this de-normalisation is given below. Example for input data: Parameter | Value f0 [N] | 86 f1 [N/(km/h)] | 0,8 f2 [N/(km/h)2] | 0,036 TM [kg] | 1590 Prated [kW] | 120 (Example 1) Prated [kW] | 75 (Example 2) Corresponding results: Pdrive = 66[km/h]/3,6 * (86 + 0,8[N/(km/h)] * 66[km/h] + 0,036[N/(km/h)] * (66[km/h])2 + 1590[kg] * 0,44[m/s2]) * 0,001 Pdrive = 18,25 kW (1) The highest wheel power class to be considered is the one containing 0,9 × Prated. Here 0,9 × 120 = 108. Power class No | Pc,j [kW] | Urban | Total trip From > | to ≤ | Time share, tC,j [%] 1 | | – 1,825 | 21,97 % | 18,5611 % 2 | – 1,825 | 1,825 | 28,79 % | 21,8580 % 3 | 1,825 | 18,246 | 44,00 % | 43,4583 % 4 | 18,246 | 34,667 | 4,74 % | 13,2690 % 5 | 34,667 | 51,088 | 0,45 % | 2,3767 % 6 | 51,088 | 67,509 | 0,045 % | 0,4232 % 7 | 67,509 | 83,930 | 0,004 % | 0,0511 % 8 | 83,930 | 100,351 | 0,0004 % | 0,0024 % 9 | 100,351 | | 0,00025 % | 0,0003 % [The highest class wheel power class to be considered is the one containing 0,9 × Prated. Here 0,9 × 75 = 67,5.] Power class No | Pc,j [kW] | Urban | Total trip From > | to ≤ | Time share, tC,j [%] 1 | All < – 1,825 | – 1,825 | 21,97 % | 18,5611 % 2 | – 1,825 | 1,825 | 28,79 % | 21,8580 % 3 | 1,825 | 18,246 | 44,00 % | 43,4583 % 4 | 18,246 | 34,667 | 4,74 % | 13,2690 % 5 | 34,667 | 51,088 | 0,45 % | 2,3767 % 6 | 51,088 | All > 51,088 | 0,04965 % | 0,4770 % 7 | 67,509 | 83,930 | — | — 8 | 83,930 | 100,351 | — | — 9 | 100,351 | All > 100,375 | — | — The cold start emissions, defined according to Appendix 4, used to calculate kw: kw11 α 0,005 cco2 cco kw1 1,008 where: kw11,608 Ha 1000 1,608 Ha where: Hais the intake air humidity [g water per kg dry air] cCO2is the dry CO2 concentration [%] cCOis the dry CO concentration [%] αis the molar hydrogen ratio NOx emissions shall not be corrected for ambient temperature and humidity. Negative intermediate results shall not be corrected. Negative final results shall be set to zero. The second-by second emissions calculated in accordance with this Appendix may be divided by a value of 1,6 solely for the cases laid down in points 9.5 and 9.6. The corrective factor of 1,6 shall be applied only once. The corrective factor of 1,6 applies to pollutant emissions but not to CO2. The components in the raw exhaust shall be measured with the measurement and sampling analysers described in Appendix 2. The raw concentrations of relevant components shall be measured in accordance with Appendix 1. The data shall be time corrected and aligned in accordance with point 3. For methane measurement using a NMC-FID, the calculation of NMHC depends on the calibration gas/method used for the zero/span calibration adjustment. When a FID is used for THC measurement without a NMC, it shall be calibrated with propane/air or propane/N2 in the normal manner. For the calibration of the FID in series with a NMC, the following methods are permitted: (a) the calibration gas consisting of propane/air bypasses the NMC; (b) the calibration gas consisting of methane/air passes through the NMC. It is strongly recommended to calibrate the methane FID with methane/air through the NMC. In method (a), the concentrations of CH4 and NMHC shall be calculated as follows: cCH4cHCw oNMC 1 EM cHCwNMC EE EM cNMHCcHCw NMC cHCw oNMC 1 EErh EE EM In method (b), the concentration of CH4 and NMHC shall be calculated as follows: cCH4cHCw NMC rh 1 EM cHCw oNMC 1 EE rh EE EM cNMHCcHCw oNMC 1 EM cHCw NMC rh 1 EM EE EM where: cHC(w/oNMC)is the HC concentration with CH4 or C2H6 bypassing the NMC [ppmC1] cHC(w/NMC)is the HC concentration with CH4 or C2H6 flowing through the NMC [ppmC1] rhis the hydrocarbon response factor as determined in point 4.3.3.(b) of Appendix 2 EMis the methane efficiency as determined in point 4.3.4.(a) of Appendix 2 EEis the ethane efficiency as determined in point 4.3.4(b) of Appendix 2 If the methane FID is calibrated through the cutter (method b), then the methane conversion efficiency as determined in point 4.4, shall be excluded from the following evaluation. Each moving average value calculated according to point 3.23.4.(a) of Appendix 2 is zero. The density used for calculating the NMHC mass shall be sorted into the de-normalized wheel power class into which the actual 3 second moving average wheel power Pw,3s,k fits. The de-normalised wheel power class limits have to be calculated according to point 3.3. The classification shall be done for all three second moving averages equal to that of total hydrocarbons at 273,15 K and 101,325 kPa and is fuel-dependent. The calculation of instantaneous mass emissions according to points 11 and 12 requires determining the exhaust mass flow rate. The exhaust mass flow rate shall be determined by one of the entire valid trip data including also all urban trip parts. Additionally all moving averages classified to urban according to the velocity limits defined in table 1-1 shall be classified into one set of urban power classes independently of the time when the moving average appeared in the trip. Then the average of all three second moving average values within a wheel power class shall be calculated for each wheel power class per parameter. The equations are described below and shall be applied once for the urban data set and once for the total data set. Classification of the 3-second moving average values into power class j (j = 1 to 9): if PC,j lower bound Pw,3s,k PC,j upper bound then: class index for emissions and velocity = j The number of 3-second moving average values shall be counted for each power class: if PC,j lower bound Pw,3s,k PC,j upper bound then: countsj = n + 1 (countsj is counting the number of 3 second moving average emission values in a power class to check later the minimum coverage demands) For a valid test a sufficient number of measured emission values have to be allocated to the relevant power classes. This demand is checked by the number of 3 second average values (counts) allocated to each power class: a minimum coverage of 5 counts is demanded for the total trip in each wheel power class up to class No 6 or up to the class containing 90 % of the rated power whatever gives the lower class number. If the counts in a wheel power class above number 6 are less than 5, the average class emission value (mgas,3s,k) and the average class velocity (v3s,k) shall be set to zero. a minimum coverage of 5 counts is required for the urban part of the trip in each wheel power class up to class No 5 or up to the class containing 90 % of the rated power whatever gives the lower class number. If the counts in the urban part of the trip in a wheel power class above number 5 are less than 5, the average class emission value (mgas,3s,k) and the average class velocity (v3s,k) shall be set to zero. The moving averages sorted in each wheel power class shall be averaged direct measurement methods specified in point 7.2 of Appendix 2. Alternatively, it is permissible to calculate the exhaust mass flow rate as described in points 10.2 to 10.4. The instantaneous exhaust mass flow rate can be calculated from the air mass flow rate and the fuel mass flow rate as follows: qmew,iqmaw,i qmf,i where: qmew,iis the instantaneous exhaust mass flow rate [kg/s] qmaw,iis the instantaneous intake air mass flow rate [kg/s] qmf,iis the instantaneous fuel mass flow rate [kg/s] If the air mass flow rate and the fuel mass flow rate or the exhaust mass flow rate are determined from ECU recording, the calculated instantaneous exhaust mass flow rate shall meet the linearity requirements specified for the exhaust mass flow rate in point 3 of Appendix 2 and the validation requirements specified in point 4.3 of Appendix 3. The instantaneous exhaust mass flow rate can be calculated from the air mass flow rate and the air-to-fuel ratio as follows: qmew,i qmaw,i 1 1AFst λi where: AFst138,0 1 α4 ε2 γ12,011 1,008 α 15,9994 ε 14,0067 δ 32,0675 γλi 100 cCO 10 42 cHCw 10 4 α4 1 2 cCO 10 43,5 cCO21 cCO 10 43,5 cCO2 ε2 δ2 cCO2 cCO 10 4 4,764 1 α4 ε2 γ cCO2 cCO 10 4 cHCw 10 4 where: qmaw,iis the instantaneous intake air mass flow rate [kg/s] A/Fstis the stoichiometric air-to-fuel ratio [kg/kg] λiis the instantaneous excess air ratio cCO2is the dry CO2 concentration [%] cCOis the dry CO concentration [ppm] cHCwis the wet HC concentration [ppm] αis the molar hydrogen ratio (H/C) βis the molar carbon ratio (C/C) γis the molar sulphur ratio (S/C) δis the molar nitrogen ratio (N/C) εis the molar oxygen ratio (O/C) Coefficients refer to a fuel Cβ Hα Oε Nδ Sγ with β = 1 for carbon based fuels. The concentration of HC emissions is typically low and may be omitted when calculating λi. If the air mass flow rate and air-to-fuel ratio are determined from ECU recording, the calculated instantaneous exhaust mass flow rate shall meet the linearity requirements specified for the exhaust mass flow rate in point 3 of Appendix 2 and the validation requirements specified in point 4.3 of Appendix 3. The instantaneous exhaust mass flow rate can be calculated from the fuel flow and the air-to-fuel ratio (calculated with A/Fst and λi according to point 10.3) as follows: m gas,j all k in classj mgas,3s,k countsjv j all k in classj v3s,k countsj Where j …wheel power class 1 to 9 according to Table 1 mgas,j…average emission value of anqmew,i qmf,i 1 AFst λi The calculated instantaneous exhaust mass flow rate shall meet the linearity requirements specified for the exhaust gas component in a wheel power class (separate value for total trip data and for the urban parts of the trip), mass flow rate in point 3 of Appendix 2 and the validation requirements specified in point 4.3 of Appendix 3. The instantaneous mass emissions [g/s] vj…average velocity in a wheel power class (separate value for total trip data and for the urban parts of the trip), [km/h] k …time step for moving average values The average values of each wheel power class shall be multiplied with the time share, tC,j per class shall be determined by multiplying the instantaneous concentration of the pollutant under consideration [ppm] with the instantaneous exhaust mass flow rate [kg/s], both corrected and aligned for the transformation time, and the respective u value of Table 1. If measured on a dry basis, the dry-wet correction according to Table 1 and summed up to produce the weighted average value for each parameter. This value represents the weighted result for a trip with the standardised power frequencies. The weighted averages point 8.1 shall be applied to the instantaneous component concentrations before executing any further calculations. If occurring, negative instantaneous emission values shall enter all subsequent data evaluations. Parameter values shall be computed for the urban part of the test data using the time shares for urban power distribution as well as for the total trip using the time shares for the total. The equations are described below and shall be applied once for the urban data set and once for the total data set. m gas 9 j 1m gas,j tc,jv 9j 1 v j tc,j The time based weighted averages enter the calculation of instantaneous emissions [g/s] as reported by the analyser, flow-measuring instrument, sensor or the ECU. The following equation shall be applied: where: mgas,iugas cgas,i qmew,i mgas,iis the mass of the exhaust component ‘gas’ [g/s] ugasis the ratio of the density of the exhaust component ‘gas’ and the overall density of the exhaust as listed in Table 1 cgas,iis the measured concentration of the emissions exhaust component ‘gas’ in the test shall be converted into distance based emissions once for the urban data set and once for the total data set as follows: For the total tripMw,gas,d mgas3600 v For the urban part of the tripMw,gas,d,U mgas,U3600 vU For particle number the same method as for gaseous pollutants shall be applied but the unit [#/s] shall be used for mPN and [#/km] exhaust [ppm] qmew,iis the measured exhaust mass flow rate [kg/s] gasis the respective component inumber of the measurement [depending on fuel] [at λ = 2, dry air, 273 K, 101.3 kPa] [u values accurate within 0,2 % for mass composition of: C=66-76 %; H=22-25 %; N=0-12 %] [NMHC on the basis of CH2.93 (for THC the ugas coefficient of CH4 shall be used for Mw,PN: For the total tripMw,PN,d mPN3600 v For the urban part of the tripMw,PN,d,U mPN3600 vU The power at the wheels (Pw,i) can be computed from the measured CO2 mass flow in 1 Hz. For this calculation the vehicle specific CO2 line (‘Veline’) shall be used. The Veline shall be calculated from the vehicle type approval test in the WLTC according to the test procedure described in UNECE Global Technical Regulation No. 15 - Worldwide harmonized Light vehicles Test Procedure (ECE/TRANS/180/Add.15). The average wheel power per WLTC phase shall be calculated in 1 Hz from the driven velocity and from the chassis dynamometer settings. For all wheel power values below the drag power shall be set to the drag power value. Pw,ivi3,6 f 0 f 1 vi f 2 vi2 TM ai 0,001 With f0, f1, f2…road load coefficients used in in the WLTP test performed with the vehicle TM…test mass of the vehicle in the WLTP test performed with the vehicle in [kg] Pdrag 0,04 Pratedif Pw,iPdrag then Pw,i Pdrag The average power per WLTC phase is calculated from the 1 Hz wheel power according to: Pw,p te j tsPw,i te ts With pphase of WLTC (low, medium, high and extra-high) tsStart time of the WLTC phase p, [s] teend time of the WLTC phase p, [s] Then a linear regression shall be made )] [u accurate within 0,2 % for mass composition of: C3=70-90 %; C4=10-30 %] [ugas is a unitless parameter; the ugas values include unit conversions to ensure that the instantaneous emissions are obtained in the specified physical unit, i.e., g/s] Fuel | ρe [kg/m3] | Component or pollutant i NOx | CO | HC | CO2 | O2 | CH4 ρgas [kg/m3] 2,053 | 1,250 | | 1,9636 | 1,4277 | 0,716 ugas, Diesel (B7) | 1,2943 | 0,001586 | 0,000966 | 0,000482 | 0,001517 | 0,001103 | 0,000553 Ethanol (ED95) | 1,2768 | 0,001609 | 0,000980 | 0,000780 | 0,001539 | 0,001119 | 0,000561 CNG | 1,2661 | 0,001621 | 0,000987 | 0,000528 | 0,001551 | 0,001128 | 0,000565 Propane | 1,2805 | 0,001603 | 0,000976 | 0,000512 | 0,001533 | 0,001115 | 0,000559 Butane | 1,2832 | 0,001600 | 0,000974 | 0,000505 | 0,001530 | 0,001113 | 0,000558 LPG | 1,2811 | 0,001602 | 0,000976 | 0,000510 | 0,001533 | 0,001115 | 0,000559 Petrol (E10) | 1,2931 | 0,001587 | 0,000966 | 0,000499 | 0,001518 | 0,001104 | 0,000553 Ethanol (E85) | 1,2797 | 0,001604 | 0,000977 | 0,000730 | 0,001534 | 0,001116 | 0,000559 The instantaneous particle number emissions [particles/s] shall be determined by multiplying the instantaneous concentration of the pollutant under consideration [particles/cm3] with the CO2 instantaneous exhaust mass flow from the bag values of the WLTC on the y-axis and from the average wheel power Pw,p per phase on the x-axis as illustrated in Figure 2. The resulting Veline equation defines the CO2 mass flow as function of the wheel power: CO 2 ikWLTC X Pw,i DWLTC CO 2 in gh Where kWLTC … slope of the Veline from WLTC, [g/kWh] DWLTC … interceptrate [kg/s], both corrected and aligned for the transformation time. If applicable, negative instantaneous emission values shall enter all subsequent data evaluations. All significant digits of intermediate results shall enter the calculation of the instantaneous emissions. The following equation shall apply: PN,icPN,iqmew,iρe where: PN,iis the particle number flux [particles/s] cPN,iis the measured particle number concentration [#/m3] normalized at 0 °C qmew,iis the measured exhaust mass flow rate [kg/s] ρeis the density of the Veline from WLTC, [g/h] The actual wheel power exhaust gas [kg/m3] at 0 °C (Table 1) The data shall be calculated from the measured CO2 mass flow as follows: Pw,iCO2i DWLTCkWLTC With CO2 in [g/h] Pw,j in [kW] The above equation can be used to provide PWi for the classificationexchanged between the measurement systems and the data evaluation software by a standardised reporting file as specified in point 2 of Appendix 8. Any pre-processing of data (e.g. time correction according to point 3 or the correction of the measured emissions as described in GPS vehicle speed signal according to point 3 7) shall be done with following additional conditions in the calculation: (I) if vi ≤ 1 km/h and if CO2i ≤ DWLTC then Pw,i = 0 (II) if vi > 1 km/h and if CO2i < 0,5 X DWLTC then Pw,i = Pdrag In time steps where (I) and (II) are valid, condition (II) shall be appliedthe control software of the measurement systems and shall be completed before the data reporting file is generated. If data are corrected or processed prior to entering the data reporting file, the original raw data shall be kept for quality assurance and control. Rounding of intermediate values is not permitted.

  1. 1 Jan 2019 – 1 Sep 2023earlier wording
  2. 27 Jul 2017 – 1 Jan 2019earlier wording
  3. 1 Jun 2017 – 27 Jul 2017earlier wording