Criteria for awarding the EU Ecolabel to wood-, cork- and bamboo- based floor covering products:
Criterion 1.Product description
Criterion 2.Wood-, cork- and bamboo-based materials
Criterion 3.General requirements for hazardous substances and mixtures
Criterion 4.Specific substance requirements
Criterion 5.Energy consumption in the production process
Criterion 6.Emissions of VOC from the floor coverings
Criterion 7.Emissions of formaldehyde from the floor coverings and the core board
Criterion 8.Fitness for use
Criterion 9.Reparability and extended guarantee
Criterion 10.Consumer information
Criterion 11.Information appearing on the EU Ecolabel
Appendix I.Guidance on the calculation of the quantity of VOC applied
Appendix II.Guidance for calculating the energy consumption in the production process
Appendix III.List of standards
The specific assessment and verification requirements are indicated within each criterion.
Where the applicant is required to provide declarations, documentation, analyses, test reports, or other evidence to show compliance with the criteria, these may originate from the applicant or its supplier(s), etc., as appropriate.
Competent bodies shall preferentially recognise attestations which are issued by bodies accredited according to the relevant harmonised standard for testing and calibration laboratories and verifications by bodies that are accredited according to the relevant harmonised standard for bodies certifying products, processes and services. Accreditation shall be carried out according to the provisions of the Regulation (EC) No 765/2008 of the European Parliament and of the Council [Regulation (EC) No 765/2008 of the European Parliament and of the Council of 9 July 2008 setting out the requirements for accreditation and market surveillance relating to the marketing of products and repealing Regulation (EEC) No 339/93 (OJ L 218, 13.8.2008, p. 30).].
Where appropriate, test methods other than those indicated for each criterion may be used if the competent body assessing the application accepts their equivalence.
Where appropriate, competent bodies may require supporting documentation and may carry out independent verifications or site visits.
As pre-requisite, the product shall meet all applicable legal requirements of the country or countries in which the product is intended to be placed on the market. The applicant shall declare the product's compliance with this requirement.
If a supplier prefers not to disclose the substances constituting a mixture to the applicant, that information can be sent directly to the competent body by the supplier.
A technical description of the floor covering including drawings that illustrate the parts or materials that form the final floor covering product, its dimensions and a description of the manufacturing process shall be provided to the competent body. That description shall be accompanied by the bill of materials for the product that shall state the total weight of the product and how this is split between the different materials used.
Compliance with the scope of the product group as defined in Article 1 shall be demonstrated.
The applicant shall provide to the competent body a declaration of compliance, supported by the following information about the floor covering:
brand/trade name [Trade name means all names under which the substance is marketed within the Union market.];
a description of the product including technical drawings that illustrate the parts or materials used in the final product;
the bill of materials: percentage composition of the raw materials, substances or mixtures in the final product in mass including any additive and surface treatment, when relevant;
a list of all the component parts [Component part means each of the layers the floor coverings consist of whose material, shape and form provide a specific function. It includes, for example, the wear or scratch resistant layer, the pattern or veneer layer, the substrate or stability layer and the backing layer.] of the product and the respective weight;
a description of the manufacturing process. Suppliers of raw materials or substances shall be described with the legal name, production site, contact details and description of the production step(s) they carried out or are part of.
The product data sheet, environmental product declaration or equivalent document can be accepted as evidence of compliance with this criterion provided that it includes the listed information.
This requirement is applied to wood, wood-based, cork, cork-based, bamboo, bamboo-based materials weighing more than 1 % of the finished product.
All wood, wood-based, cork, cork-based, bamboo, bamboo-based materials shall not originate from genetically modified organisms (GMO) and be covered by chain of custody certificates issued by an independent third party certification scheme such as the Forest Stewardship Council (FSC), the Programme for the Endorsement of Forest Certification (PEFC) or equivalent.
All virgin wood, cork and bamboo shall be covered by valid sustainable forest management certificates issued by an independent third party certification scheme such as FSC, PEFC or equivalent.
Where a certification scheme allows the mixing of uncertified material with certified and/or recycled materials in a product or production line, a minimum of 70 % of the wood, cork and/or bamboo shall be sustainable certified virgin materials and/or recycled material.
Uncertified material shall be covered by a verification system which ensures that it is legally sourced and meets any other requirement of the certification scheme with respect to uncertified material.
The certification bodies issuing forest and/or chain of custody certificates shall be accredited or recognised by that certification scheme.
The applicant shall provide to the competent body a declaration of compliance supported by a valid, independently certified chain of custody certificate of the manufacturer for all wood, wood-based, cork, cork-based, bamboo, bamboo-based material used in the product or production line and demonstrate that no virgin material is sourced from GMO. The applicant shall provide audited accounting documents that demonstrate that at least 70 % of the materials originate from forests or areas managed according to Sustainable Forestry Management principles and/or from recycled sources that meet the requirements set out by the relevant independent chain of custody scheme. FSC, PEFC or equivalent schemes shall be accepted as independent third party certification.
If the product or production line includes uncertified material, proof shall be provided that the content of uncertified virgin material does not exceed 30 % and is covered by a verification system which ensures that it is legally sourced and meets any other requirement of the certification scheme with respect to uncertified material.
The presence in the product and any component parts thereof, of substances that have been identified according to Article 59(1) of Regulation (EC) No 1907/2006 as substances of very high concern (SVHCs) or substances or mixtures that meet the criteria for classification, labelling and packaging (CLP) according to Regulation (EC) No 1272/2008 of the European Parliament and of the Council [Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006 (OJ L 353, 31.12.2008, p. 1).] for the hazards listed in Table 3.1 of this Decision, shall be restricted in accordance with points 3.a and 3.b. For the purpose of this criterion, Candidate List SVHCs and CLP hazard classifications are grouped in Table 3.1 according to their hazardous properties.
Hazards that identify a substance as being within Group 1:
substances that appear on the Candidate List for SVHCs
carcinogenic, mutagenic and/or toxic to reproduction (CMR) category 1A or 1B: H340, H350, H350i, H360, H360F, H360D, H360FD, H360Fd, H360Df
Hazards that identify a substance as being within Group 2:
category 2 CMR: H341, H351, H361f, H361d, H361df, H362
category 1 aquatic toxicity: H400, H410
category 1 and 2 acute toxicity: H300, H310, H330, H304
category 1 aspiration toxicity: H304
category 1 specific target organ toxicity (STOT): H370, H372
category 1 skin sensitiser: H317
Hazards that identify a substance as being within Group 3:
category 2, 3 and 4 aquatic toxicity: H411, H412, H413
category 3 acute toxicity: H301, H311, H331, EUH070
category 2 STOT: H371, H373
The product and any component parts thereof shall not contain SVHCs at concentrations greater than 0,10 % (weight by weight).
No derogation from this requirement shall be given to Candidate List SVHCs present in the product or any component parts thereof at concentrations greater than 0,10 % (weight by weight).
The applicant shall compile declarations of absence of SVHCs above the specified concentration limit for the product and any component parts used in the product. Declarations shall be with reference to the latest version of the Candidate List published by ECHA [ECHA, Candidate List of substances of very high concern for Authorisation, http://www.echa.europa.eu/candidate-list-table].
Substances or mixtures used by the floor covering manufacturer or his suppliers during the preparation of raw materials, manufacturing, assembly or any other treatment of the floor covering shall not be classified with any of the CLP hazards listed in Table 3.1. Restricted substances or mixtures shall include adhesives, paints, primers, varnishes, stains, resins, biocidal products, fillers, waxes, oils, joint fillers, dyes and sealants.
However, the use of such restricted substances shall be permitted if at least one of the following conditions applies:
the restricted substance or mixture was used in quantities that amount to less than 0,10 % of the total weight of the floor covering and any component part thereof;
the restricted substance changes its properties upon processing (e.g. becomes no longer bioavailable or undergoes chemical reaction) so that the restricted CLP hazards no longer apply and any unreacted residual content of the restricted substance is less than 0,10 % of the total weight of the floor covering and any component part thereof.
The applicant and/or its suppliers shall provide to the competent body a declaration of compliance with criterion 3.b. supported, where appropriate, by a list of relevant substances or mixtures used together with declarations about their hazard classification or non-classification, their added quantities and if appropriate, statements whether the substances or mixtures change their properties upon processing so that the restricted CLP hazards no longer apply. If so, the quantities of any unreacted residual content of the restricted substance shall be provided.
The following information shall be provided in relation to the hazard classification or non-classification for each of the substances:
the substance's Chemical Abstract Service (CAS) [CAS registry: https://www.cas.org/content/chemical-substances], European Community (EC) [EC inventory: http://echa.europa.eu/information-on-chemicals/ec-inventory] or other list number (where available for mixtures);
the physical form and state in which the substance or mixture is used;
harmonized CLP hazard classifications;
self-classification entries in ECHA's REACH registered substance database [ECHA, REACH registered substances database: http://www.echa.europa.eu/information-on-chemicals/registered-substances] (if no harmonized classification available);
mixture classifications according to the criteria laid down in Regulation (EC) No 1272/2008.
When considering self-classification entries in the REACH registered substance database, priority shall be given to entries from joint submissions.
Where a classification is recorded as ‘data-lacking’ or ‘inconclusive’ according to the REACH registered substance database, or when the substance has not yet been registered under the REACH system, toxicological data meeting the requirements of Annex VII to Regulation (EC) No 1907/2006 shall be provided that are sufficient to support conclusive self-classification in accordance with Annex I to Regulation (EC) No 1272/2008 and ECHA's supporting guidance. In the case of ‘data lacking’ or ‘inconclusive’ database entries, self-classifications shall be verified. For that purpose, the following information sources shall be accepted:
toxicological studies and hazard assessments by ECHA peer regulatory agencies [ECHA, Cooperation with peer regulatory agencies, http://echa.europa.eu/about-us/partners-and-networks/international-cooperation/cooperation-with-peer-regulatory-agencies.], Member State regulatory bodies or intergovernmental bodies;
a Safety Data Sheet (SDS) fully completed in accordance with Annex II to Regulation (EC) No 1907/2006;
a documented expert judgment provided by a professional toxicologist, which shall be based on a review of scientific literature and existing testing data, where necessary supported by results from new testing carried out by independent laboratories using methods approved by ECHA;
an attestation, where appropriate based on expert judgment, issued by an accredited conformity assessment body that carries out hazard assessments according to the Globally Harmonized System (GHS) or CLP hazard classification systems.
Information on the hazardous properties of substances may, in accordance with Annex XI to Regulation (EC) No 1907/2006, be generated by means other than tests, for instance through the use of alternative methods such as in vitro methods, by quantitative structure activity models or by the use of grouping or read-across.
Any recycled fibres or chips used in the manufacture of the final floor covering product shall be tested in accordance with the European Panel Federation (EPF) standard for delivery conditions of recycled wood [‘EPF Standard for delivery conditions of recycled wood’, October 2002 at: http://europanels.org/site/upload/57d9467eac5f3.pdf] or with another equivalent standard that has equal or stricter limits, and shall comply with the limits for contaminants as listed in Table 4.1.
Contaminants | Limit values | Contaminants | Limit values
Arsenic (As) | 25 | Mercury (Hg) | 25
Cadmium (Cd) | 50 | Fluorine (F) | 100
Chromium (Cr) | 25 | Chlorine (Cl) | 1000
Copper (Cu) | 40 | Pentachlorophenol (PCP) | 5
Lead (Pb) | 90 | Tar oils (benzo(a)pyrene) | 0,5
The applicant shall provide to the competent body:
a declaration from the manufacturer or the panel supplier, as appropriate, that no recycled wood, cork, bamboo or their fibres or chips were used in the floor covering, or
a declaration from the manufacturer or the panel supplier, as appropriate, that all recycled wood, cork, bamboo or their fibres or chips used have been representatively tested in accordance with the EPF standard for delivery conditions of recycled wood or with another equivalent standard that has equal or stricter limits, supported by test reports that demonstrate compliance of the recycled samples with the limits specified in Table 4.1.
The treatment of wood, cork and/or bamboo of the floor coverings with biocidal products shall not be permitted.
The following active substances shall not be permitted for in-can preservation of water-based mixtures such as adhesives or lacquers:
blend (3:1) of chloromethylisothiazolinone and methylisothiazolinone (CMIT/MIT CAS No 55965-84-9) at a concentration above 15 ppm;
methylisothiazolinone at a concentration above 200 ppm;
other isothiazolinones at a concentration above 500 ppm.
The applicant shall provide to the competent body a declaration of non-use of biocidal products or, if applicable, a declaration supported by an SDS from the water-based mixtures' suppliers stating what active substances have been used as in-can preservatives for the water-based mixtures.
Any paints, primers or varnishes used on wood, wood-based, cork, cork-based, bamboo or bamboo-based materials shall not contain substances based on the following metals: cadmium, lead, chromium VI, mercury, arsenic or selenium at concentrations exceeding 0,010 % (weight by weight) for each individual metal in the in-can paint, primer or varnish formulation.
The applicant or his supplier, as appropriate, shall provide to the competent body a declaration of compliance with this criterion and provide the respective SDS from the suppliers of the paints, primers and varnished used.
Surface treatment products used on wood, wood-based, cork, cork-based, bamboo or bamboo-based materials shall have either of the following:
a total VOC content of less than or equal to 5 % weight by weight (in-can substance concentration);
a total VOC content greater than 5 % weight by weight provided that they are shown to be applied in quantities that amount to less than 10 g/m2 of treated surface area.
The criterion relates to the total VOC in the surface treatment products with the chemical composition they have in wet form. If the products require dilution before use, the calculation is to be based on the content in the diluted product.
For the purpose of this criterion, VOC means volatile organic compound as defined in Article 2(5) of Directive 2004/42/EC.
This criterion does not apply to mixtures used for repairing (e.g. knots, checks, dents, etc.) during the manufacturing process.
The applicant shall provide to the competent body a declaration of compliance with this criterion supported by the SDS of any surface treatment substances or mixtures used on wood, wood-based, cork, cork-based, bamboo or/and bamboo-based materials. If the SDS states that the VOC content of the surface treatment substances or mixtures used is less than or equal to 5 % weight by weight, no further verification shall be necessary.
Should the VOC content information not be included in the SDS, the VOC content shall be calculated from the list of substances in the surface treatment mixture. The concentration of each VOC ingredient shall be stated as a percentage by weight.
Alternatively, if the VOC content is higher than 5 % weight by weight, the applicant shall provide a calculation demonstrating that the effective quantity of VOC applied per m2 of the treated surface area of the floor covering is less than 10 g/m2, in accordance with the guidance provided in Appendix I.
VOC content shall be less than:
3 % weight by weight in both in-can adhesives and resins used in manufacturing of the floor coverings;
1 % weight by weight in other substances apart from in-can adhesives, resins and surface treatment (criterion 4.d) used in manufacturing of the floor coverings.
Free-formaldehyde of liquid aminoplast resins used in the manufacturing of the floor coverings shall be less than 0,2 % weight by weight.
The criterion relates to the total VOC in the substances with the chemical composition they have in wet form. If the mixtures require dilution prior to use, the calculation is to be based on the content in the diluted product.
For the purpose of this criterion, VOC means volatile organic compound as defined in Article 2(5) of Directive 2004/42/EC.
This criterion does not apply to mixtures used for repairing (e.g. knots, checks, dents, etc.) during the manufacturing process.
The applicant shall provide to the competent body a declaration of compliance with the criterion supported by the SDS of any in-can adhesive, resin or other substances used or equivalent documentation that supports the declaration of compliance, together with a complete recipe with designation of quantities and CAS numbers.
If the SDS states that the VOC content is less than 3 % weight by weight of the in-can adhesive and resin used or less than 1 % weight by weight of other substances used, no further verification shall be necessary.
Should the VOC content information not be included in the SDS, the VOC content shall be calculated from the list of substances. The concentration of each VOC ingredient shall be stated as a percentage by weight.
The applicant shall provide test reports demonstrating that the free-formaldehyde content in the liquid aminoplast resins is less than 0,2 % weight by weight in accordance with standard EN1243.
Any adhesive, resin or surface treatment substance or mixture shall not contain any phthalate plasticisers that are referred to in Article 57 of Regulation (EC) No 1907/2006. The non-presence of these phthalates shall be considered as the total sum of the listed phthalates amounting to less than 0,10 % of the adhesive, resin or surface treatment substance or mixture weight (1000 mg/kg).
The applicant shall provide to the competent body either:
a declaration of compliance with the criterion from the supplier or the floor covering manufacturer stating that phthalate plasticisers were not used, or
a declaration of compliance with the criterion from the supplier or the floor covering manufacturer stating that phthalate plasticisers were used and that none of the phthalates meeting the criteria of Article 57 of Regulation (EC) No 1907/2006 have been used in the adhesive, resin or surface treatment substance or mixture. In the absence of a suitable declaration, adhesive, resin or surface treatment substance or mixture materials shall be tested for the presence of these phthalates according to the ISO 8214-6 standard.
Halogenated organic compounds shall not be permitted in the substances used in the manufacture of floor coverings (e.g. as binders, adhesives, coatings, etc.).
The applicant shall provide to the competent body a declaration of compliance supported by a declaration of non-use of halogenated organic compounds from the manufacturer of the substances. In addition, the respective SDS of the substances shall be provided.
Flame retardants shall not be permitted in the substances used in the manufacture of floor coverings.
The applicant shall provide to the competent body a declaration of compliance supported by a declaration of non-use of flame retardants from the manufacturer of the substances. In addition, the respective SDS of the substances shall be provided.
Aziridine and polyaziridine shall not be permitted in the substances used in the manufacture of floor coverings (e.g. as surface treatment, coatings, etc.).
The applicant shall provide to the competent body a declaration of compliance supported by a declaration of non-use of aziridine and polyaziridine from the manufacturer of the substances. In addition, the respective SDS of the substances shall be provided.
The average annual energy consumed during the production of the floor coverings shall be calculated as indicated in Table 5.1 and Appendix II and shall exceed the following limits (E score):
Product | E score
Solid wood floorings | > 11,0
Multi-layer wood floorings
Wood veneer floor covering