Criteria for awarding the EU Ecolabel to tourist accommodation:
Criterion 1. Basis of an Environmental Management System
Criterion 2. Staff training
Criterion 3. Information to guests
Criterion 4. General maintenance
Criterion 5. Consumption monitoring
Criterion 6. Energy efficient space heating and water heating appliances
Criterion 7. Energy efficient air conditioning and air-based heat pumps appliances
Criterion 8. Energy efficient lighting
Criterion 9. Thermoregulation
Criterion 10. Automatic switching off of HVAC and lighting
Criterion 11. Outside heating and air conditioning appliances
Criterion 12. Procurement of electricity from a renewable electricity supplier
Criterion 13. Coal and heating oils
Criterion 14. Efficient water fittings: Bathroom taps and showers
Criterion 15. Efficient water fittings: Toilets and urinals
Criterion 16. Reduction in laundry achieved through reuse of towels and bedclothes
Criterion 17. Waste prevention: Food service waste reduction plan
Criterion 18. Waste prevention: Disposable items
Criterion 19. Waste sorting and sending for recycling
Criterion 20. No smoking in common areas
Criterion 21. Promotion of environmentally preferable means of transport
Criterion 22. Information appearing on the EU Ecolabel
Criterion 23. EMAS registration, ISO certification of the tourist accommodation (up to 5 points)
Criterion 24. EMAS registration or ISO certification of suppliers (up to 5 points)
Criterion 25. Ecolabelled services (up to 4 points)
Criterion 26. Environmental and social communication and education (up to 2 points)
Criterion 27 Consumption monitoring: Energy and water sub-metering (up to 2 points)
Criterion 28. Energy efficient space heating and water heating appliances (up to 3 points)
Criterion 29. Energy efficient air conditioning and air-based heat pumps appliances (up to 3,5 points)
Criterion 30. Air-based heat pumps up to 100 kW heat output (3 points)
Criterion 31. Energy efficient household appliances and lighting (up to 4 points)
Criterion 32. Heat recovery (up to 3 points)
Criterion 33. Thermoregulation and window insulation (up to 4 points)
Criterion 34. Automatic switch off appliances/devices (up to 4,5 points)
Criterion 35. District heating/cooling and cooling from cogeneration (up to 4 points)
Criterion 36. Electric hand driers with proximity sensor (1 point)
Criterion 37. Space Heater emissions (1,5 points)
Criterion 38. Procurement of electricity from a renewable electricity supplier (up to 4 points)
Criterion 39. On site self-generation of electricity through renewable energy sources (up to 5 points)
Criterion 40. Heating energy from renewable energy sources (up to 3,5 points)
Criterion 41. Swimming pool heating (up to 1,5 points)
Criterion 42. Efficient water fittings: Bathroom taps and showers (up to 4 points)
Criterion 43. Efficient water fittings: Toilets and urinals (up to 4,5 points)
Criterion 44. Dishwasher water consumption (2,5 points)
Criterion 45. Washing machine water consumption (3 points)
Criterion 46. Indications on water hardness (up to 1,5 points)
Criterion 47. Optimised pool management (up to 2,5 points)
Criterion 48. Rainwater and grey water recycling (up to 3 points)
Criterion 49. Efficient irrigation (1,5 points)
Criterion 50. Native or non-invasive alien species used in outdoor planting (up to 2 points)
Criterion 51. Paper Products (up to 2 points)
Criterion 52. Durable goods (up to 4 points)
Criterion 53. Beverages provision (2 points)
Criterion 54. Detergents and toiletries procurement (up to 2 points)
Criterion 55. Minimisation of the use of cleaning products (1,5 point)
Criterion 56. De-icing (1 point)
Criterion 57. Used textiles and furniture (up to 2 points)
Criterion 58. Composting (up to 2 points)
Criterion 59. Waste water treatment (up to 3 points)
Criterion 60. No smoking in rooms (1 point)
Criterion 61. Social policy (up to 2 points)
Criterion 62. Maintenance vehicles (1 point)
Criterion 63. Environmentally preferable means of transport offer (up to 2,5 points)
Criterion 64. Unsealed surfaces (1 point)
Criterion 65. Local and organic products (up to 4 points)
Criterion 66. Pesticide avoidance (2 points)
Criterion 67. Additional environmental and social actions (up to 3 points)
The specific assessment and verification requirements are indicated within each criterion set out in Sections A and B.
Where the applicant is required to provide declarations, documentation, analyses, test reports, or other evidence to show compliance with the criteria, these may originate from the applicant or its supplier(s), etc., as appropriate.
Competent bodies shall preferentially recognise attestations which are issued by bodies accredited according to the relevant harmonised standard for testing and calibration laboratories and verifications by bodies that are accredited according to the relevant harmonised standard for bodies certifying products, processes and services. Accreditation shall be carried out according to the provisions of Regulation (EC) No 765/2008 of the European Parliament and of the Council [Regulation (EC) No 765/2008 of the European Parliament and of the Council of 9 July 2008 setting out the requirements for accreditation and market surveillance relating to the marketing of products and repealing Regulation (EEC) No 339/93 (OJ L 218, 13.8.2008, p. 30).].
Information extracted from environmental statements submitted under the eco-management and audit scheme [Regulation (EC) No 1221/2009 of the European Parliament and of the Council of 25 November 2009 on the voluntary participation by organisations in a Community eco-management and audit scheme (EMAS), repealing Regulation (EC) No 761/2001 and Commission Decisions 2001/681/EC and 2006/193/EC (OJ L 342, 22.12.2009, p. 1).] (EMAS) of the Union are considered equivalent means of proof as the attestations mentioned in the previous paragraph.
Where appropriate, test methods other than those indicated for each criterion may be used if the competent body assessing the application accepts their equivalence.
Where appropriate, competent bodies may require supporting documentation and may carry out independent verifications.
Competent bodies shall carry out an initial on-site visit before awarding the EU Ecolabel licence and may perform follow up on-site visits periodically during the award period.
As a pre-requisite, the services shall meet all respective legal requirements of the country (countries) in which the ‘tourist accommodation’ is located. In particular, the following shall be guaranteed:
The physical structure respects Union, national and local laws and regulations regarding energy efficiency and thermal insulation, water sources, water treatment and waste water disposal (including chemical toilets), waste collection and disposal, maintenance and servicing of equipment, safety and health dispositions and any relevant laws or regulations of the area related to landscape and biodiversity conservation.
The enterprise is operational and registered, as required by national or local laws and its staff are legally employed and insured. For this purpose, staff shall have a national legal written contract, shall be paid at least the national or regional minimum wage set by collective agreements (in the absence of collective agreements, the staff shall be paid at least the legal national or regional minimum wage), and shall have working hours complying with the national law.
The applicant shall declare and demonstrate the service's compliance with those requirements, using independent verification or documentary evidence without prejudice of data protection national law (e.g. construction license/authorisation, declarations of professional technicians explaining how national legislation and local regulations related to the above mentioned aspects of the building are met, copy of a written social policy, copies of contracts, statements of employee's registration in the national insurance system, official documentation/register recording the names and number of employees by the local Government's Employment Inspectorate or Agent) and moreover direct random staff interview could be done during on-site visit.
The tourist accommodation shall set the basis of an Environmental Management System by implementing the following processes:
an environmental policy identifying the most relevant environmental aspects regarding energy, water and waste relevant to the accommodation,
a precise action programme establishing targets on environmental performance regarding identified environmental aspects, which shall be set at least every 2 years, taking into consideration requirements set by this EU Ecolabel Decision.
If environmental aspects identified are not addressed by this EU Ecolabel, targets should preferably be based on environmental performance indicators and benchmarks of excellence set by the reference document on best environmental management practice for the tourism sector [Commission Decision (EU) 2016/611 of 15 April 2016 on the reference document on best environmental management practice, sector environmental performance indicators and benchmarks of excellence for the tourism sector under Regulation (EC) No 1221/2009 on the voluntary participation by organisations in a Community eco- management and audit scheme (EMAS) (OJ L 104, 20.4.2016, p. 27).] (EMAS),
an internal evaluation process allowing verifying at least yearly organisation performances with regard to the targets defined in the action program and setting correction actions if needed.
Information on the processes mentioned in the previous paragraph shall be available for consultation by the guests and staff.
Comments and feedback from guests collected by means of the questionnaire referred in criterion 3 shall be evaluated in the internal evaluation process and in the action programme, if necessary.
The applicant shall provide a declaration of compliance with this criterion, together with:
a copy of the environmental policy,
the action programme, and
the evaluation report, which shall be made available to the competent body within 2 years after the application, and the updated version every 2 years.
Applicants registered under EMAS or certified according to ISO 14001 shall be deemed to comply. In this case, ISO 14001 certificate or EMAS registration shall be provided as a means of proof. In case of ISO 14001 certification, a report summarising performances with regard to the targets defined in the action programme shall be joined to the application.
The tourist accommodation shall provide information and training to the staff (including subcontracted external staff), including written procedures or manuals, to ensure the application of environmental measures and to raise awareness of environmentally responsible behaviour in accordance with the mandatory and applicable optional criteria in this EU Ecolabel. In particular, the following aspects shall be included on the staff training:
the environmental policy and action plan of the tourist accommodation and awareness of the EU Ecolabel for tourist accommodation;
energy saving actions in relation to lights, air conditioning and heating systems when the staff leave the room or windows are opened;
water saving actions in relation to leaks checking, watering, changes of sheets and towels frequency and backwashing pool procedure;
chemical use minimisation actions in relation to chemical products for cleaning, dishwashing, sanitising, laundry and other special cleaners (e.g. swimming pool backwashing) which shall be used only where they are necessary; and if information on the dosage is available, the consumption limits of the mentioned products shall be those indicated on the packaging or recommended by the producer;
waste reduction and separation actions in relation to disposable items and disposal categories;
environmentally preferable means of transport available to staff;
according to criterion 3, the relevant information that staff is required to provide to guests.
Adequate training shall be provided to all new staff within 4 weeks of starting employment and an update on the above mentioned aspects for all other staff at least once a year.
The applicant shall provide a declaration of compliance with this criterion, together with details of the training programme, its content, and an indication of which staff have received what training and when. The dates and types of the staff training shall be recorded as evidence that this training update has taken place.
The tourist accommodation shall also provide information to the guests to ensure the application of environmental measures and to raise awareness of environmentally responsible behaviour in accordance with the mandatory and applicable optional criteria in this EU Ecolabel. That information shall be actively given to the guests in oral or written form at the reception or in-room and shall include, in particular, the following aspects:
environmental policy of the tourist accommodation and awareness of the EU Ecolabel for tourist accommodation;
energy saving actions in relation to lights, air conditioning and heating systems when the guests leave the room or windows are opened;
water saving actions in relation to leaks checking, and changes of sheets and towels frequency;
waste reduction and separation actions in relation to disposable items, disposal categories and items that shall not be disposed of with the waste water. In addition, a poster or any other information material which would give advices to reduce food waste shall be displayed in the breakfast and dining rooms;
environmentally preferable means of transport available to guests;
the tourist accommodation shall provide information to guests on available local touristic points of interest, local guides, local restaurants, markets, craft centres.
Guests shall be given a questionnaire, via internet or at premises, asking about their views on the general environmental aspects of the tourist accommodation listed in point (a) and their overall satisfaction with the facilities and services of the tourist accommodation. A clear procedure which records customer comments, complaints, replies given and corrective actions taken shall be in place.
The applicant shall provide a declaration of compliance with this criterion, together with copies of the information provided for the guests. The applicant shall indicate the procedures in place for distributing and collecting the information and the questionnaire, and for taking the feedback into account.
Preventative maintenance of appliances/devices shall be carried out at least yearly, or more often if required by law or relevant manufacturer's instructions. The maintenance shall include the inspection of possible leakage and assurance of the proper functioning at least for energy equipment (e.g. heating, ventilation and air conditioning (HVAC) appliances, refrigeration systems, etc.) and water equipment (e.g. plumbing fixtures, irrigation systems, etc.) at the accommodation premises.
Appliances using refrigerants covered by the Regulation (EU) No 517/2014 of the European Parliament and of the Council [Regulation (EU) No 517/2014 of the European Parliament and of the Council of 16 April 2014 on fluorinated greenhouse gases and repealing Regulation (EC) No 842/2006 (OJ L 150, 20.5.2014, p. 195).], shall be inspected and maintained as follow:
for equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO2 equivalent or more, but of less than 50 tonnes of CO2 equivalent: at least every 12 months or, where a leakage detection system is installed, at least every 24 months;
for equipment that contains fluorinated greenhouse gases in quantities of 50 tonnes of CO2 equivalent or more, but of less than 500 tonnes of CO2 equivalent: at least every 6 months or, where a leakage detection system is installed, at least every 12 months;
for equipment that contains fluorinated greenhouse gases in quantities of 500 tonnes of CO2 equivalent or more: at least every 3 months or, where a leakage detection system is installed, at least every 6 months.
All maintenance activities have to be registered in a specific maintenance register, specifying the approximate amounts of the water leaking from the water supply equipment.
The applicant shall provide a declaration of compliance, together with a brief description of the maintenance programme, details of the persons or companies carrying out the maintenance and the maintenance register.
The tourist accommodation shall have procedures for collecting and monitoring data monthly or, at least, yearly, on the following aspects as a minimum:
specific energy use (kWh/guest night and/or kWh/m2 (of indoor area)year);
percentage of final energy use met by renewable energy generated on site (%);
water consumption per guest-night (litres/guest-night) including the water used for irrigation (if applicable) and any other activities related to water consumption;
waste generation per guest-night (kg/guest-night). Food waste shall be monitored separately [Applicable if food service is provided and local waste management facilities permit the separate collection of organic waste.];
consumption of chemical products for cleaning, dishwashing, laundry, sanitising and other special cleaners (e.g. swimming pool backwashing) (kg or litres/guest-night), specifying if they are ready-to-use or undiluted;
percentage of ISO Type I label products (%) used under the applicable optional criteria in this EU Ecolabel Decision.
The applicant shall provide a declaration of compliance with this criterion, together with a description of the collecting and monitoring procedures. The tourist accommodation shall report a short summary of the data collected for the above-listed consumption parameters together with the internal evaluation report mentioned in criterion 1, which shall be made available to the competent body within 2 years after the application, and every 2 years.
Water-based space heating appliances installed within the duration of the EU Ecolabel licence shall:
be a high efficiency cogeneration unit as defined by Directive 2012/27/EU of the European Parliament and of the Council [Directive 2012/27/EU of the European Parliament and of the Council of 25 October 2012 on energy efficiency, amending Directives 2009/125/EC and 2010/30/EU and repealing Directives 2004/8/EC and 2006/32/EC (OJ L 315, 14.11.2012, p. 1).], or
have seasonal space heating energy efficiency and/or GHG emission limits in accordance with the values in the following tables, calculated as stated in Commission Decision 2014/314/EU [Commission Decision 2014/314/EU of 28 May 2014 establishing the criteria for the award of the EU Ecolabel for water-based heaters (OJ L 164, 3.6.2014, p. 83).]:
Water-based space heater type | Efficiency indicator
All space heating appliances except solid biomass boiler heaters and heat pump heaters |
Minimum Seasonal Space Heating Energy Efficiency
(ηs) ≥ 98 %
Solid biomass boiler heaters |
Minimum Seasonal Space Heating Energy Efficiency
(ηs) ≥ 79 %
Heat pump heaters (two options are valid for heat pumps using refrigerants with GWP ≤ 2000, option 2 is mandatory for heat pumps using refrigerants with GWP > 2000) | Option 1 — Minimum Seasonal Space Energy Heating Efficiency/refrigerant GWP values
ηs ≥ 107 %/[0-500]
ηs ≥ 110 %/(500-1000]
ηs ≥ 120 %/(1000-2000]
Option 2 — GHG emission limits
150 g CO2-equivalent/kWh heating output
Local space heating appliances installed within the duration of the EU Ecolabel licence shall comply with the minimum seasonal space heating energy efficiency set out in Commission Regulation (EU) 2015/1185 [Commission Regulation (EU) 2015/1185 of 24 April 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for solid fuel local space heaters (OJ L 193, 21.7.2015, p. 1).] or in Commission Regulation (EU) 2015/1188 [Commission Regulation (EU) 2015/1188 of 28 April 2015 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for local space heaters (OJ L 193, 21.7.2015, p. 76).].
Water heating appliances installed within the duration of the EU Ecolabel licence shall have at least the following relevant energy efficiency indicators:
[As defined in Annex II to Commission Delegated Regulation (EU) No 812/2013 (1).] [As defined in Annex VI to Commission Regulation (EU) No 814/2013 (2).]
Commission Delegated Regulation (EU) No 812/2013 of 18 February 2013 supplementing Directive 2010/30/EU of the European Parliament and of the Council with regard to the energy labelling of water heaters, hot water storage tanks and packages of water heater and solar device (OJ L 239, 6.9.2013, p. 83).
Commission Regulation (EU) No 814/2013 of 2 August 2013 implementing Directive 2009/125/EC of the European Parliament and of the Council with regard to ecodesign requirements for water heaters and hot water storage tanks (OJ L 239, 6.9.2013, p. 162).
Water heater type | Energy efficiency indicator
All water heaters with a declared load profile ≤ S | Energy Class A
All water heaters except heat pump water heaters, with a declared load profile > S and ≤ XXL | Energy Class A
Heat pump water heaters with a declared load profile > S and ≤ XXL | Energy Class A+
All water heaters with a declared load profile > XXL (3XL and 4XL) | Water heating energy efficiency ≥ 131 %
Existing cogeneration units shall comply with the definition of high efficiency in Annex III to Directive 2004/8/EC of the European Parliament and of the Council [Directive 2004/8/EC of the European Parliament and of the Council of 11 February 2004 on the promotion of cogeneration based on a useful heat demand in the internal energy market and amending Directive 92/42/EEC (OJ L 52, 21.2.2004, p. 50).] or Annex II to the Directive 2012/27/EU if installed after 4 December 2012.
Existing hot-water boilers fired with liquid or gaseous fuels as defined in Council Directive 92/42/EEC [Council Directive 92/42/EEC of 21 May 1992 on efficiency requirements for new hot-water boilers fired with liquid or gaseous fuels (OJ L 167, 22.6.1992, p. 17).] shall comply with efficiency standards at least equivalent to three stars as stated in that Directive. The efficiency of boilers excluded from Directive 92/42/EEC shall comply with the manufacturer's instructions and with national and local legislation on efficiency, but for such existing boilers (with the exception of biomass boilers) efficiency lower than 88 % shall not be accepted.