1 ANNEX, Decision_act (EU) 2015/801

In force

This document is the first Sectoral Reference Document (SRD) according to Article 46 of Regulation (EC) No 1221/2009 on the voluntary participation by organisations in a Community eco-management and audit scheme (EMAS). With a view to facilitating the understanding of this SRD, this introduction provides an outline of its legal background and its use.

The SRD is based on a detailed scientific and policy report [The scientific and policy report is publicly available on the JRC/IPTS website at the following address: http://susproc.jrc.ec.europa.eu/activities/emas/documents/RetailTradeSector.pdf The conclusions on best environmental management practices and their applicability as well as the identified specific environmental performance indicators and the benchmarks of excellence contained in this Sectoral Reference Document are based on the findings documented in the scientific and policy report. All the background information and technical details can be found there.] developed by the Institute for Prospective Technological Studies (IPTS), one of the seven institutes of the European Commission's Joint Research Centre (JRC).

The Community Eco-Management and Audit Scheme (EMAS) was introduced in 1993 for voluntary participation by organisations, by Council Regulation (EEC) No 1836/93 [Council Regulation (EEC) No 1836/93 of 29 June 1993 allowing voluntary participation by companies in the industrial sector in a Community eco-management and audit scheme (OJ L 168, 10.7.1993, p. 1).]. Subsequently, EMAS has undergone two major revisions:

Regulation (EC) No 761/2001 of the European Parliament and of the Council [Regulation (EC) No 761/2001 of the European Parliament and of the Council of 19 March 2001 allowing voluntary participation by organisations in a Community eco-management and audit scheme (EMAS) (OJ L 114, 24.4.2001, p. 1).],

Regulation (EC) No 1221/2009.

An important new element of the latest revision, which came into force on 11 January 2010, is the development of sectoral reference documents (SRDs) reflecting best environmental management practice for specific sectors, introduced by Article 46 of Regulation (EC) No 1221/2009. They include best environmental management practices (BEMPs), environmental performance indicators for specific sectors and, where appropriate, benchmarks of excellence and rating systems identifying performance levels.

The Eco-Management and Audit Scheme (EMAS) is a scheme for voluntary participation by organisations which commit to continuous environmental improvement. Within this framework, the present Sectoral Reference Document (SRD) provides sector-specific guidance to the retail trade sector and points out a number of options for improvement and best practices. The SRD is aimed at helping and supporting all organisations which intend to improve their environmental performance by providing ideas and inspiration as well as practical and technical guidance.

The SRD primarily addresses organisations that are already EMAS-registered, secondly organisations that consider registering with EMAS in the future, and thirdly also those which have implemented another environmental management system or those without a formal environmental management system wishing to learn more about best environmental management practices in order to improve their environmental performance. Consequently, the objective of this document is to support all organisations and actors in the retail trade sector to focus on relevant environmental aspects, both direct and indirect, and to find information on best practices, as well as appropriate sector specific environmental performance indicators to measure their environmental performance, and benchmarks of excellence.

According to Regulation (EC) No 1221/2009, EMAS-registered organisations are required to prepare an environmental statement (Article 4(1)(d)). When assessing the environmental performance, the relevant SRD shall be taken into account. Commission Decision 2013/131/EU [Commission Decision 2013/131/EU of 4 March 2013 establishing the user's guide setting out the steps needed to participate in EMAS, under Regulation (EC) No 1221/2009 of the European Parliament and of the Council on the voluntary participation by organisations in a Community eco-management and audit scheme (EMAS) (OJ L 76, 19.3.2013, p. 1).] establishing the user's guide setting out the steps needed to participate in EMAS (the ‘EMAS User's Guide’) also refers to the legal character of the EMAS Sectoral Reference Documents. Both the EMAS User's Guide and this decision state that it is an obligation for an EMAS registered organisation to clarify in the environmental statement how the SRD, when available, was taken into account; i.e. how the SRD has been used to identify measures and actions, and possibly to set priorities, to (further) improve the environmental performance. In addition, this decision also states that meeting the identified benchmarks of excellence is not mandatory because the voluntary character of EMAS leaves the assessment of the feasibility of the benchmarks, in terms of costs and benefits, to the organisations themselves.

The information in this document is based on the direct data supplied by stakeholders themselves followed by a subsequent analysis of the European Commission's Joint Research Centre. A Technical Working Group, comprising experts and stakeholders of the sector, applied their expert judgement together with the European Commission's Joint Research Centre and ultimately agreed and approved the described benchmarks. This means that the information provided on the appropriate sector specific environmental performance indicators and the benchmarks of excellence in this document correspond to the levels of environmental performance that can be achieved by the best performing organisations from the sector. With respect to the environmental statement, Article 4(1)(d) of Regulation (EC) No 1221/2009 refers to ANNEX IV to that Regulation, where it is stated that the environmental statement shall also contain reporting on the core indicators and on other relevant existing environmental performance indicators. The so-called ‘other relevant existing environmental performance indicators’ (ANNEX IV(C)(3)) relate to the more specific environmental aspects as identified in the environmental statement and shall be reported in addition to the core indicators. For this purpose, the SRD shall be taken into account also (ANNEX IV(C)(3)). Where justified on technical grounds, an organisation may conclude that one or more of the EMAS core indicators and one or more of the sector-specific indicators presented in the SRD are not relevant for them and may not report on them. For instance, for a non-food retailer, it is not necessary to report on energy efficiency indicators for commercial food refrigeration as this is not relevant for them. When choosing the relevant indicators, it should be considered that some indicators are closely linked to the implementation of certain best practices. Therefore, their applicability is limited to organisations implementing such best environmental management practices. However, if a best environmental management practice is suitable to an organisation, even if not applied, it is recommendable that the organisation report on the associated indicator, at least, to establish a comparable baseline.

The indicators presented were selected as those most commonly used by exemplary organisations within the sector. Organisations may check which of the selected environmental performance indicators (or appropriate alternatives) are the most suitable in each case.

EMAS environmental verifiers shall check if and how the SRD was taken into account by the organisation when preparing its environmental statement (Article 18(5)(d) of Regulation (EC) No 1221/2009). This means that when undertaking their activities, accredited environmental verifiers will need evidence from the organisation on how the SRD has been taken into account. They shall not check compliance with the described benchmarks of excellence, but they shall verify evidence on how the SRD was used as a guide to identify proper voluntary measures that the organisation can implement to improve its environmental performance.

EMAS registration is an ongoing process. This means that every time an organisation plans to improve its environmental performance (and reviews its environmental performance) it shall consult the SRD on specific topics to provide inspiration about which issues to tackle next in a step-wise approach.

This document consists of four chapters. Chapter 1 introduces the EMAS legal background and describes how to use this document, while Chapter 2 defines the scope of this SRD. Chapter 3 briefly describes the different best environmental management practices (BEMPs) together with information on their applicability, mainly with respect to new and existing installations and/or new and existing stores as well as to SMEs. For each BEMP, the suitable environmental performance indicators and the related benchmarks of excellence are also given. For each of the different measures and techniques outlined, more than one environmental performance indicator is mentioned to reflect the fact that different indicators are used in practice.

Finally, Chapter 4 presents a comprehensive table with the most relevant environmental performance indicators, associated explanations and related benchmarks of excellence.

This SRD addresses the environmental management of retail trade sector organisations. This sector is characterised within the statistical classification of economic activities established by Regulation (EC) No 1893/2006 of the European Parliament and of the Council [Regulation (EC) No 1893/2006 of the European Parliament and of the Council of 20 December 2006 establishing the statistical classification of economic activities NACE Revision 2 and amending Council Regulation (EEC) No 3037/90 as well as certain EC Regulations on specific statistical domains (OJ L 393, 30.12.2006, p. 1).] with NACE code 47 (NACE Rev. 2): ‘retail trade, except of motor vehicles and motorcycles’. Retailing of services, e.g. restaurants, hairdressers, travel agents are excluded.

It covers the whole value chain for the products sold in retail stores, as described in the following input/output scheme.

The main environmental aspects to be managed by the organisations belonging to the retail trade sector are set out in Table 2.1.

For each category, the table shows the aspects covered in this SRD. These environmental aspects were selected as the most relevant for retailers. However, the environmental aspects to be managed by specific retailers should be assessed on a case by case basis. Environmental aspects, such as waste water, hazardous waste, biodiversity or materials for other areas than those listed could also be relevant.

[This is an approximate classification of the nature of environmental aspects according to the definitions given in Regulation (EC) No 1221/2009. The direct or indirect nature of each environmental aspect should be assessed for each specific case.] [Those products manufactured by a company which are sold under another company's (e.g. a retailer's) brand. Own-brand products are also called private labels.]

Category | Character | Aspects covered in this document

Energy performance | Direct | Building, Heating, Ventilation and Air Conditioning system (HVAC), refrigeration, lighting, appliances, renewable energy, energy monitoring

Air Emissions | Direct | Refrigerants

Supply Chain | Indirect | Business strategies, product prioritisation, improvement mechanisms, choice editing, environmental criteria, information and dissemination, environmental-labelling (including own-brand products)

Transport and logistics | Direct/Indirect | Monitoring, procurement, decision-making, transport modes, distribution network, planning, packaging design

Waste | Direct | Food waste, packaging, return systems

Materials and resources | Direct | Paper consumption

Water | Direct | Rainwater collection and treatment

Influence on consumers | Indirect | Environmental aspects associated with consumption, e.g. plastic bags

Consequently, the ‘Best Environmental Management Practices (BEMPs)’ presented are grouped as follows:

BEMPs to improve the energy performance, including refrigerants management

BEMPs to improve the environmental sustainability of retail supply chains

BEMPs to improve transport and logistics operations

BEMPs concerning waste

other BEMPs (reduced consumption and use of more environmentally-friendly paper for commercial publications, rainwater collection and reuse, and influencing consumer environmental behaviour).

The BEMPs cover the most significant environmental aspects of the sector.

BEMP is to improve the envelope of existing retailers' buildings to minimise energy losses to an acceptable and feasible level, through the application of several techniques, such as those shown in Table 3.1. Moreover, BEMP is to optimise the building envelope design in order to fulfil demanding standards going beyond existing regulations, especially for new buildings.

Envelope element | Technique

Wall/façade/roof/floor — cellar ceiling | Change insulation materials

Techniques to increase the insulation thickness

Windows/glazing | Change to more efficient glazing

Change to more efficient sashes and frames

Shading | Use of external and internal shading devices

Air tightness | Improvement of doors

Fast acting doors

Sealing

Introduce buffer sections

Overall envelope | Orientation

Maintenance

Technically, it is feasible for every new and existing building or building unit. Tenants may implement mechanisms to influence owners and should be aware of the importance of the building envelope in their environmental performance. Building envelope retrofitting requires significant investment. Generally, this BEMP produces cost savings, but with long payback times and, therefore, it is recommendable to apply this BEMP along with other major renovations of the store (e.g. store layout, lighting, safety, structural, extensions, etc.) in order to reduce its cost.

The applicability of this BEMP to small enterprises [A small enterprise is defined as an enterprise which employs fewer than 50 persons and whose annual turnover and/or annual balance sheet total does not exceed EUR 10 million (Commission Recommendation 2003/361/EC of 6 May 2003 concerning the definition of micro, small and medium-sized enterprises (OJ L 124, 20.5.2003, p. 36)).] is usually quite limited, due to the high investment needed and the lack of influence on the building characteristics.

[This benchmark can also be seen in the light of the Directive 2010/31/EU on the energy performance of buildings and the national definitions of nearly zero energy buildings (NZEB). An illustration/example of this is a threshold 20 kWh/m2yr (http://eur-lex.europa.eu/legal-content/EN/TXT/?uri=CELEX:52013DC0483).]

Environmental performance indicators | Benchmark of excellence

(i1) Specific energy use of the store per m2 (sales area) and year.

(i2) Specific energy use of the store per m2 (sales area) and year in terms of primary energy.

(b1) Specific energy use per m2 of sales area for heating, cooling and air conditioning lower or equal to 0 kWh/m2yr if waste heat from refrigeration can be recovered. Otherwise, lower or equal to 40 kWh/m2yr for new buildings and 55 kWh/m2yr for existing buildings.

BEMP is to retrofit existing HVAC (Heating, Ventilation and Air Conditioning) systems in order to reduce energy consumption and improve indoor air quality. BEMP is to optimise the design of HVAC systems in new buildings, using innovative systems to reduce primary energy demand and to increase efficiency.

The application of best design practices should allow best integration within the building envelope, avoiding oversizing and using the orientation of the building as a way of minimising overall energy consumption. In particular, for new stores, the following may be relevant: the use of glazing, waste heat from refrigeration, renewable energy, heat pumps, and other innovative systems. Indoor air quality monitoring and energy management systems are considered best practices regarding HVAC maintenance.

This BEMP is fully applicable to new buildings. In any existing building, the HVAC system can be retrofitted in order to reduce energy consumption, although building characteristics would have an influence on the impact of retrofitting the HVAC system. The climatic influence is very relevant in order to select what techniques can be implemented. The application of new HVAC systems in an existing building, e.g. the installation of cogeneration plants, heat recovery systems and integrated design concepts, such as the Passive House standard, can be applied partially with acceptable economic performance. The store layout has a strong influence on the performance of HVAC, especially those design specifications related to the refrigeration process, where a huge amount of waste heat can be recovered.

For small enterprises, the degree of influence on the HVAC design can be negligible, although they should participate in the implementation and recommendation of the described BEMP.

Environmental performance indicators | Benchmark of excellence

(i1) Specific energy use of the store per m2 (sales area) and year.

(i2) Specific energy use of the store per m2 (sales area) and year in terms of primary energy.

(b1) Specific energy use per m2 of sales area for heating, cooling and air conditioning lower or equal to 0 kWh/m2yr if waste heat from refrigeration can be recovered. Otherwise, lower or equal to 40 kWh/m2yr for new buildings and 55 kWh/m2yr for existing buildings.

BEMP is to use integrated design concepts for the whole building or for parts of it to reduce the energy demand of the store. Integrated concepts minimise the energy use and associated costs of a building, while achieving good thermal comfort conditions for the occupants. Some exemplary requirements are shown in Table 3.2.

Requirements | Examples of measures to achieve them

The building energy need for space heating and cooling must be lower than 15 kWh/m2yr

The specific heat load must not exceed 10 W/m2

The building must not leak more air than 0,6 times its volume per hour

Total primary energy use cannot be higher than 120 kWh/m2yr

Improved insulation. Recommended U-values less than 0,15 W/m2K

Design without thermal bridges

Windows U-values lower than 0,85 W/m2K

Air tight. Mechanical ventilation with heating recovery from exhaust air

Install solar thermal systems or heat pumps (final energy demand excludes the contribution of solar and ambient energy used on site to produce heat)

Integrated concepts are usually implemented during the design of new buildings. The concept is partially suitable for existing buildings, as several elements can be integrated without high investment costs. The climatic conditions can also influence the decision to apply this concept. For example, the Passive House standard was mainly developed by German and Swedish researchers, but it may be implemented in warmer climates. The investment costs of a building designed according to exemplary integrated approaches do not exceed 10-15 % of extra cost compared to a conventional construction. The life cycle cost analysis reveals that the passive house building design represents the minimum life cycle cost, as the heating system required is relatively simple and the heating power installed is limited.

For small enterprises, the use of integrated design concepts to minimise energy demand of new buildings can be regarded as a cost-efficient procurement activity, without any specific restriction other than extra initial investment.

Environmental performance indicators | Benchmark of excellence

(i1) Specific energy use of the store per m2 (sales area) and year.

(i2) Specific energy use of the store per m2 (sales area) and year in terms of primary energy.

(b1) Specific energy use per m2 of sales area for heating, cooling and air conditioning lower or equal to 0 kWh/m2yr if waste heat from refrigeration can be recovered. Otherwise, lower or equal to 40 kWh/m2yr for new buildings and 55 kWh/m2yr for existing buildings.

BEMP is to recover the waste heat from the refrigeration cycle and to maximise its use. Food retailers are able, under certain circumstances, to produce excess heat even after using the heat for space heating, which can be delivered to other parts of the same building or to other buildings.

The measures should be taken into account for new or existing buildings of food retailers and the operation of these systems would have different results depending on different factors:

—Building size and uselarge retailers' stores are usually not alone in their buildings. Therefore, the ‘neighbourhood’ (e.g. small shops in a shopping centre) is a potential consumer of the excess heat. As a general rule, a grocery store with a typical refrigeration load and an optimised envelope would recover enough energy to heat twice its own surface.

—HVAC design and maintenanceall the elements of the HVAC system should be correctly designed and maintained. Exhaust air heat recovery, on-demand control of ventilation with CO2 sensors and monitoring of air tightness and indoor air quality are strongly recommended techniques.

—The refrigeration loadsmaller shops offer more refrigerated goods per square metre of sales area and the efficiency in refrigeration is lower. In addition, the trend to increase the amount of refrigerated goods available is also important. The size of the shop does not influence the technical applicability of integrated approaches, but the cost-efficiency of the whole system is lower for small shops.

—Climatic conditionsin cold climates, the load for refrigeration is lower than for warmer regions. At the same time, the heat demand of northern European buildings is high, so the integration would depend on the quality of the building envelope. For the warmest climates, e.g. Mediterranean countries of Europe, the cooling demand can be very significant and the air tightness of the building can make the internal gains increase. An optimised ventilation design is, therefore, necessary. Mechanical cooling at night and variable indoor temperature (e.g. 21-26 °C) are also recommended techniques.

—Ambient temperaturein the integration of the refrigeration cycle, there is a limit to ambient temperature, which depends on the system design, where the waste heat generation rate is not enough to keep a comfortable temperature inside the buildings. An extra heating source may be needed but this, again, depends on the quality of the building envelope.

This article is long: the rest is at the official publication.