The objective of this TSI is to enhance the accessibility of rail transport to persons with disabilities and persons with reduced mobility.
The technical scope of this TSI is defined in Article 2(1) of the Regulation.
The geographical scope of this TSI is defined in Article 2(2) of the Regulation.
This TSI applies to all the public areas of stations dedicated to the transport of passengers that are controlled by the railway undertaking, infrastructure manager or station manager. This includes the provision of information, the purchase of a ticket and its validation if needed, and the possibility to wait for the train.
This TSI applies to rolling stock which is in the scope of the Annex to Regulation (EU) No 1302/2014 (LOC&PAS TSI) and which is intended to carry passengers.
This TSI does not apply to rolling stock intended for other purposes than the carriage of persons. Persons accompanying a freight train or riding on other rail vehicles than those intended for passengers shall be subject to conditions set up by the railway undertaking and published on its website.
This TSI applies to the procedures enabling a coherent operation of the infrastructure and rolling stock subsystems when passengers are persons with disabilities and persons with reduced mobility.
This TSI applies to visual and audible passenger information systems located in stations and in rolling stock.
‘Person with disabilities and person with reduced mobility’ means any person who has a permanent or temporary physical, mental, intellectual or sensory impairment which, in interaction with various barriers, may hinder their full and effective use of transport on an equal basis with other passengers or whose mobility when using transport is reduced due to age.
The transport of oversized items (for example: bicycles and bulky luggage) is not within the scope of this TSI.
Definitions related to rolling stock: refer to the LOC&PAS TSI point 2.2.
‘Interoperable wheelchair transportable by train’ An interoperable wheelchair transportable by train is a wheelchair the characteristics of which permit the full usage of all features of rolling stock designed for wheelchair users. The characteristics of an interoperable wheelchair transportable by train are within the limits specified in Appendix M.
Accessibility data consists of the information related to the accessibility of passenger railway stations that needs to be collected, maintained and exchanged, that is to say, of a description of the characteristics and equipment of the passenger railway stations. Where relevant that description is complemented by the information regarding the stations' state of conformity to this TSI.
An obstacle-free route is a link between two or more public areas dedicated to the transport of passengers such as specified in point 2.1.1. It can be navigated by all persons with disabilities and reduced mobility. In order to achieve this, the route can be divided to better meet the needs of all persons with disabilities and reduced mobility. The combination of all the parts of the obstacle free route constitutes the route accessible for all persons with disabilities and reduced mobility.
A step-free route is a division of an obstacle-free route that meets the needs of mobility impaired persons. Changes in level are avoided or, when they cannot be avoided, they are bridged via ramps or lifts.
‘Tactile signs’ and ‘tactile controls’ are signs or controls, which include raised pictograms, raised characters or Braille lettering.
The station manager is an organisational entity in a Member State, which has been made responsible for the management of a railway station and which may be the infrastructure manager.
Safety information is information that shall be given to passengers so that they know in advance how they have to behave in case of an emergency.
Safety instructions are the instructions that shall be given to passengers in case of an emergency so that they understand what to do.
A level access is an access from a platform to the doorway of a rolling stock for which it can be demonstrated that:
The gap between the door sill of that doorway (or of the extended bridging plate of that doorway) and the platform does not exceed 75 mm measured horizontally and 50 mm measured vertically and
The rolling stock has no internal step between the door sill and the vestibule.
The following tables indicate the essential requirements, as set out in Annex III to Directive (EU) 2016/797 of the European Parliament and of the Council [Directive (EU) 2016/797 of the European Parliament and of the Council of 11 May 2016 on the interoperability of the rail system within the European Union (OJ L 138, 26.5.2016, p. 44).], that are met by the specifications set out in Chapter 4 of this TSI for the scope of this TSI.
The essential requirements that are not listed in the table are not relevant within the scope of this TSI.
[Essential Requirement from Commission Directive 2013/9/EU of 11 March 2013 amending Annex III to Directive 2008/57/EC (OJ L 68, 12.3.2013, p. 55).]
Infrastructure | Reference to Essential Requirement in Annex III to Directive (EU) 2016/797
Element of the TSI Domain | Reference point of this Annex | Safety | Reliability and Availability | Health | Environ-mental protection | Technical compatibility | Accessibility
Parking facilities for persons with disabilities and persons with reduced mobility | 4.2.1.1 | | | | | | 2.1.2
Obstacle-free route | 4.2.1.2 | 2.1.1 | | | | | 2.1.2
Doors and entrances | 4.2.1.3 |
1.1.1
2.1.1
2.1.2
Floor surfaces | 4.2.1.4 | 2.1.1 | | | | | 2.1.2
Highlighting of transparent obstacles | 4.2.1.5 | 2.1.1 | | | | | 2.1.2
Toilets and baby-nappy changing facilities | 4.2.1.6 |
1.1.5
2.1.1
2.1.2
Furniture and free-standing devices | 4.2.1.7 | 2.1.1 | | | | | 2.1.2
Ticketing, information desks and customer assistance points | 4.2.1.8 | 2.1.1 | 2.7.3 | | | 2.7.1 |
2.1.2
2.7.5
Lighting | 4.2.1.9 | 2.1.1 | | | | | 2.1.2
Visual information: signposting, pictograms, printed or dynamic information | 4.2.1.10 | | | | | 2.7.1 |
2.1.2
2.7.5
Spoken information | 4.2.1.11 | 2.1.1 | 2.7.3 | | | 2.7.1 |
2.1.2
2.7.5
Platform width and edge of platform | 4.2.1.12 | 2.1.1 | | | | | 2.1.2
End of platform | 4.2.1.13 | 2.1.1 | | | | | 2.1.2
Boarding aids on platforms | 4.2.1.14 | 1.1.1 | | | | | 2.1.2
Level track crossing at stations | 4.2.1.15 | 2.1.1 | | | | | 2.1.2
Rolling Stock | Reference to Essential Requirement in Annex III of Directive (EU) 2016/797
Element of the TSI Domain | Reference point of this Annex | Safety | Reliability and Availability | Health | Environ-mental protection | Technical compatibility | Accessibility
Seats | 4.2.2.1 | | | 1.3.1 | | | 2.4.5
Wheelchair spaces | 4.2.2.2 | 2.4.1 | | | | | 2.4.5
Doors | 4.2.2.3 |
1.1.1
1.1.5
2.4.1
1.2 | | | | 2.4.5
Lighting | 4.2.2.4 | 2.4.1 | | | | | 2.4.5
Toilets | 4.2.2.5 | 2.4.1 | | | | | 2.4.5
Clearways | 4.2.2.6 | | | 1.3.1 | | | 2.4.5
Customer information | 4.2.2.7 | 2.4.1 | 2.7.3 | | | 2.7.1 |
2.4.5
2.7.5
Height changes | 4.2.2.8 | 1.1.5 | | | | | 2.4.5
Handrails | 4.2.2.9 | 1.1.5 | | | | | 2.4.5
Wheelchair accessible sleeping accommodation | 4.2.2.10 | 2.4.1 | | | | | 2.4.5
Step position for vehicle access and egress | 4.2.2.11 | 1.1.1 | 2.4.2 | | |
1.5
2.4.3
2.4.5
Boarding aids | 4.2.2.12 | 1.1.1 | | | |
1.5
2.4.3
2.4.5
The rail system of the Union, to which Directive (EU) 2016/797 applies and of which the subsystems are parts, is an integrated system whose consistency shall be verified. This consistency shall be checked in particular with regard to the specifications of each subsystem, its interfaces vis-à-vis the system in which it is integrated as well as the operating and maintenance rules.
The functional and technical specifications of the subsystems and their interfaces, described in points 4.2 and 4.3, do not impose the use of specific technologies or technical solutions, except where this is strictly necessary for the interoperability of the Union rail network. But innovative solutions for interoperability may require new specifications and/or new assessment methods. In order to allow technological innovation, these specifications and assessment methods shall be developed by the process described in article 6 of the Regulation.
Taking account of all the applicable essential requirements, the basic parameters related to accessibility for persons with disabilities and persons with reduced mobility are set out for the subsystems infrastructure and rolling stock in point 4.2 of this TSI. The operational requirements and responsibilities are set out in Commission Implementing Regulation (EU) 2019/773 [Commission Implementing Regulation (EU) 2019/773 of 16 May 2019 on the technical specification for interoperability relating to the operation and traffic management subsystem of the rail system within the European Union and repealing Decision 2012/757/EU (OJ L 139I 27.5.2019, p. 5).] (OPE TSI) and in point 4.4 of this TSI.
In light of the essential requirements in Section 3, the functional and technical specifications of the infrastructure subsystem related to accessibility for persons with disabilities and persons with reduced mobility are arranged as follows:
Parking facilities for persons with disabilities and persons with reduced mobility
Obstacle-free routes
Doors and entrances
Floor surfaces
Highlighting of transparent obstacles
Toilets and baby nappy changing facilities
Furniture and free-standing devices
Ticketing, information desks and customer assistance points
Lighting
Visual information: signposting, pictograms, printed or dynamic information
Spoken information
Platform width and edges of platforms
End of platforms
Boarding aids stored on platforms
Level track crossings
The basic parameters that are specified in points 4.2.1.1 — 4.2.1.15 apply to the scope of the infrastructure subsystem that is defined in point 2.1.1; they can be divided into two categories:
Those for which technical details need to be specified, such as the parameters relative to the platforms and how to reach the platforms. In this first case, the basic parameters are specifically described and the technical details to be satisfied in order to fulfil the requirement are detailed.
Those for which technical details are not necessary to be specified, such as the value of ramps or the characteristics of parking places. In this second case, the basic parameter is defined as a functional requirement that can be met by applying several technical solutions.
The table 3 below indicates the category of each of the basic parameters.
Basic Parameter | Technical details provided | Functional requirement only
Parking facilities for persons with disabilities and persons with reduced mobility | | Complete point 4.2.1.1
Obstacle-free route |
Location of the routes
Width of the obstacle-free route
Threshold
Double handrails
Type of lift
Height of braille signs
Detailed characteristics
Doors and entrances |
4.2.1.3(2): Door width
4.2.1.3(4): Height of door operating device
4.2.1.3(1)
4.2.1.3(3)
Floor surfaces | 4.2.1.4(2): Floor irregularities | 4.2.1.4(1): Slip resistance
Highlighting of transparent obstacles | | Complete point 4.2.1.5
Toilets and baby nappy changing facilities | | Complete point 4.2.1.6
Furniture and free-standing devices | | Complete point 4.2.1.7
Ticketing, Information desks and Customer Assistance points | 4.2.1.8(5): Passageway for ticket control machines |
4.2.1.8(1) to (4)
4.2.1.8(6)
Lighting | 4.2.1.9(3): Lighting on platforms | 4.2.1.9(1), 4.2.1.9(2), 4.2.1.9(4): Lighting in other locations
Visual information: signposting, pictograms, printed or dynamic information |
Detail of information to be provided
Location of information
Detailed characteristics of visual information
Spoken information | Complete point 4.2.1.11 |
Platform width and edge of platform |
4.2.1.12(2) to (5)
4.2.1.12(6) to (9): Presence of the items
4.2.1.12 (1)
4.2.1.12(6) to (9): Characteristics of contrast and of visual and tactile markings
End of platform | 4.2.1.13: Presence of the items | 4.2.1.13: Characteristics of contrast and of visual and tactile markings
Boarding aids stored on platforms | Complete point 4.2.1.14 |
Passenger track level crossing at stations | Complete point 4.2.1.15 |
Where a station specific parking area exists, there shall be sufficient and adapted parking spaces reserved for persons with disabilities and persons with reduced mobility eligible to utilise them at the nearest practicable position, within the parking area, to an accessible entrance.
Obstacle free routes shall be provided that interconnect the following public areas of the infrastructure if provided:
stopping points for other connecting modes of transport within the station confines (for example, taxi, bus, tram, metro, ferry, etc.);
car parks
accessible entrances and exits
information desks
visual and audible information systems
ticketing facilities
customer assistance
waiting areas
toilet facilities
platforms
All obstacle-free routes, footbridges and subways, shall have a free width of a minimum of 160 cm, except in areas that are specified in points 4.2.1.2.2(3a) (ramps), 4.2.1.3(2) (doors), 4.2.1.12(3) (platforms) and 4.2.1.15(2) (level crossings).
Obstacle-free route floor surfaces and ground surfaces shall have low reflecting properties.
All obstacle-free routes, footbridges and subways, shall have a free width of a minimum of 160 cm except in areas that are specified in points 4.2.1.3 (2) (doors), 4.2.1.12 (3) (platforms) and 4.2.1.15 (2) (level crossings)).
Where thresholds are installed on a horizontal route, they shall contrast with the surrounding floor and shall not be higher than 2,5 cm.
Where an obstacle-free route includes a change in level, there shall be a step-free route providing an alternative to stairs for mobility impaired people.
Steps and stairs on the obstacle-free routes shall have a minimum width of 160 cm measured between the handrails
As a minimum, the first and last steps of a flight of stairs shall be indicated by a contrasting band. This requirement shall apply from a single step.
As a minimum, tactile warning surface indicators shall be installed before the first descending step of staircases of three steps or more.
Ramps shall be installed for persons with disabilities and persons with reduced mobility unable to use stairs where lifts are not provided. They shall have a moderate gradient. A steep gradient is allowed for ramps on short distances only.
When they are used as a complement to stairs, ramps may have a width of 120 cm measured at floor surface.
Stairs of three steps or more and ramps shall be provided with handrails on both sides and at two levels.
Lifts shall be provided where ramps are not available and shall be at least of type 2 in accordance with the specification referenced in Appendix A, Index [1]. Type 1 lifts are allowed in the case of stations being renewed or upgraded only.
Escalators and moving walks shall be designed in accordance with the specification referenced in Appendix A, Index [2].
Level track crossings can form part of an obstacle-free route when they comply with the requirements of point 4.2.1.15.
Obstacle-free routes shall be clearly identified by visual information as detailed in point 4.2.1.10.
Information on the obstacle-free route shall be given to visually impaired people by a walking surface that has tactile and contrasting indicators as a minimum. This point does not apply to obstacle free routes to and from car parks.
If more than one facility of a certain type of public area are provided, the route to at least one of them shall be indicated by tactile and contrasting walking surface indicators.
Tactile walking surface indicators can be omitted when the route is indicated unambiguously by built or natural elements, such as edges and surfaces that can be followed tactually and visually.
Technical solutions using remotely controlled audible devices or telephone applications are permitted to be used in addition or as an alternative. When they are intended to be used as an alternative, they shall be treated as innovative solutions.
If there are handrails or walls within reach along the obstacle-free route to the platform, they shall have brief information (for example platform-number or direction-information). The information shall be in Braille or prismatic-letters or numbers. The information shall be located on the handrail, or on the wall at a height between 145 cm and 165 cm.
This point applies to all doors and entrances that are on obstacle-free routes, with the exception of doors giving access to the toilets which are not dedicated to persons with disabilities and persons with reduced mobility.
Doors shall have a minimum clear useable width of 90 cm and shall be operable by persons with disabilities and persons with reduced mobility.
It is permitted to use manual, semi-automatic or automatic doors.
Door operating devices shall be available at a height of between 80 cm and 110 cm.
All floor coverings, ground surfaces and stair tread surfaces shall be slip resistant.
Within the station buildings there shall be no irregularities in excess of 0,5 cm at any given point in floor walking surface areas, except for thresholds, drainage channels and tactile walking surface indicators.
Transparent obstacles on or along the routes used by passengers, consisting of glass doors or transparent walls, shall be marked. These markings shall highlight the transparent obstacles. They are not required if passengers are protected from impact by other means — for example, by handrails or continuous benches.
If toilets are provided at a station, then a minimum of one unisex cubicle shall be wheelchair accessible.
If baby nappy changing facilities are provided at a station, then a minimum of one baby nappy changing facility shall be accessible to both men and women wheelchair users.
All items of furniture and free-standing devices at stations shall contrast with their background, and have rounded edges.
Within the station confines, furniture and free-standing devices (including cantilevered and suspended items) shall be positioned where they do not obstruct blind or visually impaired people, or they shall be detectable by a person using a long cane.
On each platform where passengers are allowed to wait for trains, and at every waiting area, there shall be a minimum of one area fitted with seating facilities and a space for a wheelchair.
When this area is weather protected, it shall be accessible by a wheelchair user.
Where manual ticket sales counters, information desks and customer assistance points are provided, a minimum of one desk shall be accessible to a wheelchair user and to people of small stature and a minimum of one desk shall be fitted with an induction loop system for hearing assistance.
If there is a glass barrier between the passenger and sales person at the ticket counter, this shall either be removable or, if not removable, an intercom system shall be fitted. Any such glass barrier shall consist of clear glass.
If electronic devices are fitted that displays pricing information to the sales person, such devices shall also be fitted that display the price to the person purchasing the ticket.
Where ticket vending machines are provided at a station, a minimum of one of those machines shall have an interface that is reachable by a wheelchair user and people of small stature. This requirement applies to each ticket vendor providing vending machines in the station.
If ticket control machines are fitted, a minimum of one of the machines shall have a free passageway with a minimum width of 90 cm and shall be able to accommodate an occupied wheelchair up to 1250 mm in length. In the case of upgrade or renewal, a minimum width of 80 cm is permitted.
If turnstiles are used, there shall be a non-turnstile access point available for use by persons with disabilities and persons with reduced mobility at all operational times.
The illuminance level of the external areas of the station shall be sufficient to facilitate way finding and to highlight the changes of level, doors and entrances.
The illuminance level along obstacle-free routes shall be adapted to the visual task of the passenger. Particular attention shall be paid to the changes of levels, ticket vending offices and machines, information desks and information displays.
The platforms shall be illuminated in accordance with the specification referenced in Appendix A, Index [3] and Index [4].
Emergency lighting shall provide sufficient visibility for evacuation and for identification of fire-fighting and safety equipment.
The following information shall be provided:
Safety Information and Safety Instructions.
Warning, prohibition and mandatory actions signs.
Information concerning the departure of trains.
Identification of station facilities, where provided, and access routes to those facilities.
The fonts, symbols and pictograms used for visual information shall contrast with their background.
Signposting shall be provided at all points where passengers need to make a route taking decision and at intervals on the route. Signage, symbols and pictograms shall be applied consistently over the whole route.
The information concerning the departure of trains (including destination, intermediate stops, platform number and time) shall be available and suitable for reading from a height of 160 cm at least in one location in the station.
The typeface used for texts shall be easily readable.
All safety, warning, mandatory action and prohibition signs shall include pictograms.
Tactile information signage shall be fitted in:
toilets, for functional information and call for aid if appropriate,
lifts in accordance with the specification referenced in Appendix A, Index [1].
Time information presented in digits shall be in the 24 h system.
The following specific graphic symbols and pictograms shall be fitted with the wheelchair symbol in accordance with Appendix N:
directional information for wheelchair specific routes;
indication of the wheelchair accessible toilets and other amenities if provided;
if there is train configuration information on the platform, indication of the wheelchair boarding location.
The symbols are permitted to be combined with other symbols (for example: lift, toilet, etc.).
Where inductive loops are fitted, those shall be indicated by a sign as described in Appendix N.
In wheelchair accessible toilets, where hinged handrails are provided, a graphic symbol showing the rail in both the stowed and deployed position shall be provided.