6 ANNEX Va MEASURING SYSTEMS FOR ELECTRIC VEHICLE SUPPLY EQUIPMENT (MI-011), Directive (EU) 2014/32

In forcesince 10 Oct 2028

The relevant requirements of Annex I, the specific requirements of this Annex and the conformity assessment procedures listed in this Annex apply to measuring systems for EVSE.

A measuring system for EVSE is a system that includes all relevant metrological functions related to the conductive transfer (either direction), at a specified transfer point, of active electrical energy between EVSE (such as charging stations for electric vehicles) and electric vehicles (such as motor vehicles, rail engines, boats, vessels and aircraft).

Such measuring systems shall not be considered as utility measuring instruments as referred to in Annex I.

The metrological functions in a measuring system for EVSE can also be provided by an active electrical energy meter for which a conformity assessment procedure has been successfully completed in accordance with Annex V to this Directive. The result of that conformity assessment shall be taken into account when performing the conformity assessment for the measuring system for EVSE as set out in this Annex.

I | = | the electrical current flowing through the measuring system for EVSE at the transfer point;

Ist | = | the lowest declared value of I at which the measuring system for EVSE registers electrical energy, and, for AC only, also at unity power factor (polyphase measuring systems with balanced load);

Imin | = | the value of I above which the error lies within base maximum permissible errors (BMPEs), and, for AC only, also polyphase measuring systems with balanced load;

Itr | = | the value of I above which the error lies within the smallest BMPE corresponding to the class index of the measuring system for EVSE;

Imax | = | the maximum value of I for which the error lies within the BMPEs;

U | = | for AC, root mean square (RMS) value of the electrical voltage applied by or to the measuring system for EVSE at the transfer point; for DC, value of the electrical voltage supplied to or from the measuring system for EVSE at the transfer point;

Un | = | the specified reference voltage(s);

f | = | the frequency of the voltage supplied by or to the measuring system for EVSE, for AC measuring systems only;

fn | = | the specified reference frequency, for AC measuring systems only;

PF | = | power factor = cosφ = the cosine of the phase difference φ between I and U, for AC measuring systems only;

harmonic | = | part of a signal that has a frequency that is an integer multiple of the fundamental frequency of the power input to the measuring system for EVSE, the fundamental frequency being, generally, the nominal frequency, fn, for AC measuring systems only;

d | = | distortion factor which is the ratio of the RMS value of the harmonic content to the RMS value of the fundamental term, and which is equal to the total harmonic distortion using the fundamental as the reference, for AC measuring systems only;

MMQ | = | minimum measured quantity of energy delivered in a transaction for which the manufacturer specifies that the measuring system for EVSE will meet the MPE of the measuring system for EVSE’s accuracy class;

transfer point | = | point at which an electric vehicle is connected to the measuring system for EVSE;

critical fault | = | failure of the device when subjected to a disturbance in which the device appears to function correctly, but where the legally relevant data is incorrect or the shift in the accuracy of the measurements exceeds that specified in the tests;

Base Maximum Permissible Error (BMPE) | = | extreme values of the error (of indication) of the measuring system for EVSE, when the current (AC EVSE and DC EVSE) and voltage (DC EVSE) are varied within the intervals given by the rated operating conditions, and when that EVSE is otherwise operated at reference conditions.

The manufacturer shall specify the class index of the measuring system for EVSE. The class indices are defined as: Class A, B and C.

Accuracy shall be determined at the transfer point.

If energy exchanged at the transfer point is in the form of DC, then DC energy shall be the measurand; if AC energy is exchanged at the transfer point, then AC active energy shall be the measurand.

For the purposes of Annex I, the overall MPE shall be determined as the root of the quadratic sum of BMPE and the allowable error shifts for variations in frequency, voltage and temperature.

The manufacturer shall specify the rated operating conditions of the measuring system for EVSE, in particular, the values of fn, Un, Ist, Imin, Itr and Imax, the temperature range, and, for DC measuring systems, also the output voltage range.

For the current values specified, the measuring system for EVSE shall fulfil the conditions given in Table 1.

Class A | Class B | Class C

Ist | ≤ 0,05 × Itr | ≤ 0,04 × Itr | ≤ 0,04 × Itr

Imin | ≤ 0,5 × Itr | ≤ 0,5 × Itr | ≤ 0,3 × Itr

Imax | ≥ 10 × Itr | ≥ 10 × Itr | ≥ 10 × Itr

The voltage, frequency and power factor ranges within which the measuring system for EVSE shall satisfy the BMPE requirements are specified in Table 2.

For AC measuring systems:

(a)

the voltage, frequency and power factor ranges shall be at least:

(i)

0,9·Un ≤ U ≤ 1,1·Un;

(ii)

0,98·fn ≤ f ≤ 1,02·fn;

(iii)

PF ≥ 0,9;

(b)

the measuring system for EVSE shall operate correctly when the supply voltage distortion is less than 10 % and the load current distortion is less than 3 % at all harmonics indices;

(c)

the MMQ shall be: MMQ ≤ 0,1 kWh.

For DC measuring systems, the following shall apply:

(a)

the output voltage range that can be measured by the measuring system for EVSE shall be between the lowest and the highest rated output voltage;

(b)

the MMQ shall be: MMQ ≤ 1 kWh.

When current (AC measuring systems and DC measuring systems) and voltage (DC measuring systems) are varied within the intervals given by the rated operating conditions, and when the measuring system for EVSE is otherwise operated at reference conditions, the percentage errors shall not exceed the limits given in Table 2 for the specified class index.

BMPEs in percent at reference conditions and defined load current levels

Current | Power factor (only for AC) | A (2 %) | B (1 %) | C (0,5 %)

Ist ≤ I < Imin | > 0,9 | ± 25 | ± 15 | ± 10

Imin ≤ I < Itr | > 0,9 | ±2,5 | ±1,5 | ± 1

Itr ≤ I < Imax | > 0,9 | ± 2 | ± 1 | ±0,5

The measuring system for EVSE shall not exploit the BMPEs or systematically favour any party.

For measuring systems for EVSE including a cable with its connector between the point at which the energy is measured and the transfer point (‘cable with connector’), either of the following shall apply:

(a)

the cable with connector is not replaceable and is secured by an appropriate hardware seal; or

(b)

if the cable with connector is intended to be replaceable while the measuring system for EVSE is under seal, it shall be:

identified in the relevant conformity assessment of the measuring system for EVSE as interchangeable and the measuring system for EVSE shall be marked with the characteristics of compatible cables with connectors,

marked with its characteristics and unique identification; and its replacement units shall also bear such marking, and

sealed separately in such a way that the replacement does not require access to, or breaking of, the metrologically sealed parts of the measuring system for EVSE.

The replacement of the cable with connector shall not affect the metrological properties of the measuring system for EVSE.

The measuring system for EVSE shall be designed and manufactured in such a way that when exposed to disturbances critical faults do not occur and shifts in the accuracy of the measurements do not exceed the values given in points 5.2 and 5.3.

When there is a foreseeable high risk due to lightning or where overhead supply networks are predominant, the metrological characteristics of the measuring system for EVSE shall be protected.

In the case of a disturbance, the legally relevant data shall be correct or the shift in the accuracy of the measurements shall not exceed 1,0 BMPE even if the measuring system for EVSE appears to function correctly. Ceasing to function is not a critical fault. If a disturbance interrupts a transaction, either of the following shall apply:

(a)

the transaction is concluded when the disturbance occurs; or

(b)

the transaction continues when the disturbance is removed.

When the load current is held constant at a point within the rated operating range with the measuring system for EVSE otherwise operated at reference conditions, and when any single influence quantity is varied from its value at reference conditions to its extreme values specified in Tables 3 and 4, the variation of error shall be such that the additional percentage error is not outside the values for error shift specified in Tables 3 and 4. The measuring system for EVSE shall continue to function after the completion of each of those tests.

Influence quantity | Current | Limits for temperature coefficient (%/K) for the measuring system for EVSE of class | Type of Current

A (2 %) | B (1 %) | C (0,5 %)

Temperature coefficient, c, over any interval of the temperature range, which is not less than 15 K and not greater than 23 K (i) | Itr ≤ I ≤ Imax | ±0,1 | ±0,05 | ±0,03 | AC and DC

Influence quantity | Value | Current | Maximum permissible error shift (%) for the measuring system for EVSE of class | Type of Current

A (2 %) | B (1 %) | C (0,5 %) |

Self-heating | Continuous current at Imax | Imax | ± 1 | ±0,5 | ±0,25 | AC and DC

Conducted disturbances, low frequency | 2 kHz–150 kHz | Itr ≤ I ≤ Imax | ± 3 | ± 2 | ± 2 | AC and DC

Continuous (DC) magnetic induction of external origin | 200 mT at 30 mm from magnetic core surface | Itr ≤ I ≤ Imax | ± 3 | ±1,5 | ±0,75 | AC and DC

Magnetic field (AC, power frequency) of external origin (ii) | 400 A/m | Itr ≤ I ≤ Imax | ±2,5 | ±1,3 | ±0,5 | AC and DC

Radiated, RF, electromagnetic fields | f = 80 MHz–6000 MHz, Field strength ≤ 10 V/m | Itr ≤ I ≤ Imax | ± 3 | ± 2 | ± 1 | AC and DC

Conducted disturbances, induced by radio frequency fields (ii) | f = 0,15 MHz–80 MHz, Amplitude ≤ 10 V | Itr ≤ I ≤ Imax | ± 3 | ± 2 | ± 1 | AC and DC

Operation of ancillary devices | Ancillary devices operated with I = Itr and Imax | Itr ≤ I ≤ Imax | ±0,7 | ±0,3 | ±0,15 | AC and DC

Voltage variation (ii) | 0,9 × Un to 1,1 × highest Un | Itr ≤ I ≤ Imax | ± 1 | ±0,7 | ±0,2 | AC

Frequency variation of mains (ii) | Each fn ± 2 % | Itr ≤ I ≤ Imax | ±0,8 | ±0,5 | ±0,2 | AC

Harmonics in voltage and current circuits (ii) |

d < 5 % I

d < 10 % U

Itr ≤ I ≤ Imax | ± 1 | ±0,6 | ±0,3 | AC

Reversed phase sequence (AC 3-phase only) (ii) | Any two phases interchanged | Itr ≤ I ≤ Imax | ±1,5 | ±1,5 | ±0,1 | AC

Table notes:

(i)

In the case of a measuring system for EVSE with an active electrical energy meter for which a conformity assessment procedure has been successfully completed in accordance with Annex V to this Directive, the temperature test can be limited to a check of correct functioning at the extreme temperatures foreseen in the measuring system for the EVSE enclosure.

(ii)

Not required for a measuring system for EVSE with an active electrical energy meter for which a conformity assessment procedure has been successfully completed in accordance with Annex V to this Directive if the specifications meet or exceed those of the accuracy class specified by the manufacturer.

The electrical energy measured shall be displayed in kilowatt-hours or their decimal multiples.

Member States shall ensure that the intended use determines the foreseen and foreseeable practical working conditions, namely the rated operating conditions, so that the measuring system for EVSE is suitable for its use.

The conformity assessment procedures referred to in Article 17 that the manufacturer can choose between are:

B + F or B + D or G or H1.