The specific assessment and verification requirements are indicated within each criterion.
Where the applicant is required to provide declarations, documentation, analyses, test reports, or other evidence to show compliance with the criteria, these may originate from the applicant and/or his supplier(s) and/or their suppliers, etc., as appropriate.
Competent bodies shall preferentially recognise tests which are accredited according to ISO 17025 and verifications performed by bodies which are accredited under the EN 45011 standard or an equivalent international standard.
Where appropriate, test methods other than those indicated for each criterion may be used if the competent body assessing the application accepts their equivalence.
Where appropriate, competent bodies may require supporting documentation and may carry out independent verifications.
As pre-requisite, the product must meet all respective legal requirements of the country (countries) in which the product is intended to be placed on the market. The applicant shall declare the product's compliance with this requirement.
Criteria for awarding the EU Ecolabel to bed mattresses:
Latex foam
Polyurethane (PUR) foam
Wire and springs
Coconut fibres
Textiles (fabrics and fibres used as mattress cover and/or filling materials)
Glues and adhesives
Flame retardants
Biocides
Plasticizers
Excluded or limited substances and mixtures
Emission of specified volatile organic compounds (SVOCs, VOCs, VVOCs) from the mattress
Technical performance
Design for disassembly and recovery of materials
Information appearing on the EU Ecolabel
Additional information to consumers
The Ecolabel criteria reflect the best environmental performing products on the market of bed mattresses.
Whilst the use of chemical products and release of pollutants is part of the production process, the use of hazardous substances are excluded whenever possible or limited to the minimum necessary to provide an adequate function and at the same time strict quality and safety standards to the mattress. For this purpose, derogation conditions for specific substances/groups of substances are granted in exceptional circumstances, in order not to shift the environmental burden to other life cycle phases or impacts and only when there are no viable alternatives existing on the market.
Note: The following requirements need to be met only if latex foam contributes to more than 5 % of the total weight of the mattress.
The concentrations in the latex foam of the substances listed below shall not exceed the following values:
[Only for foams composed of natural latex for at least 20 % by weight.]
Group of substances | Substance | Limit value (ppm) | Assessment and verification conditions
Chlorophenols | mono- and di-chlorinated phenols (salts and esters) | 1 | A
Other chlorophenols | 0,1 | A
Heavy metal | As (Arsenic) | 0,5 | B
Cd (Cadmium) | 0,1 | B
Co (Cobalt) | 0,5 | B
Cr (Chromium), total | 1 | B
Cu (Copper) | 2 | B
Hg (Mercury) | 0,02 | B
Ni (Nickel) | 1 | B
Pb (Lead) | 0,5 | B
Sb (Antimony) | 0,5 | B
Pesticides | Aldrin | 0,04 | C
o,p-DDE | 0,04 | C
p,p-DDE | 0,04 | C
o,p-DDD | 0,04 | C
p,p-DDD | 0,04 | C
o,p-DDT | 0,04 | C
p,p-DDT | 0,04 | C
Diazinone | 0,04 | C
Dichlorfenthion | 0,04 | C
Dichlorvos | 0,04 | C
Dieldrin | 0,04 | C
Endrin | 0,04 | C
Heptachlor | 0,04 | C
Heptachlorepoxide | 0,04 | C
Hexachlorobenzene | 0,04 | C
Hexachlorocyclohexane | 0,04 | C
α-Hexachlorocyclohexane | 0,04 | C
β-Hexachlorcyclohexane | 0,04 | C
γ-Hexachlorocyclohexane (Lindane) | 0,04 | C
δ-Hexachlorocyclohexane | 0,04 | C
Malathion | 0,04 | C
Methoxichlor | 0,04 | C
Mirex | 0,04 | C
Parathion-ethyl | 0,04 | C
Parathion-methyl | 0,04 | C
Other specific substances that are restricted | Butadiene | 1 | D
A. For clorophenols the applicant shall provide a report presenting the results of the following test procedure. 5 g of sample shall be milled and clorophenols shall be extracted in the form of phenol (PCP), sodium salt (SPP) or esters. The extracts shall be analysed by means of gas chromatography (GC). Detection shall be made with mass spectrometer or electron capture detector (ECD).
B. For heavy metals the applicant shall provide a report presenting the results of the following test procedure. Milled sample material is eluted in accordance with DIN 38414-S4 or equivalent in a ratio of 1:10. The resultant filtrate shall be passed through a 0,45 μm membrane filter (if necessary by pressure filtration). The solution obtained shall be examined for the content of heavy metals by inductively coupled plasma optical emission spectrometry (ICP-OES), also known as inductively coupled plasma atomic emission spectrometry (ICP-AES), or by atomic absorption spectrometry using a hydride or cold vapour process.
C. For pesticides the applicant shall provide a report presenting the results of the following test procedure: 2 g of sample is extracted in an ultrasonic bath with a hexane/dichloromethane mixture (85/15). The extract is cleaned up by acetonitrile agitation or by adsorption chromatography over florisil. Measurement and quantification are determined by gas chromatography with detection on an electron capture detector or by coupled gas chromatography/mass spectrometry. The testing on pesticides is requested for latex foams with a content of at least 20 % natural latex.
D. For butadiene the applicant shall provide a report presenting the results of the following test procedure. Following milling and weighing of the latex foam, headspace sampling shall be performed. Butadiene content shall be determined by gas chromatography with detection by flame ionisation.
The room concentrations of the substances reported below, calculated through the test chamber method, shall not exceed the following values after a period of 24 hours.
[N-nitrosodimethylamine (NDMA), N-nitrosodiethylamine (NDEA), N-nitrosomethylethylamine (NMEA), N-nitrosodi-i-propylamine (NDIPA), N-nitrosodi-n-propylamine (NDPA), N-nitrosodi-n-butylamine (NDBA), N-nitrosopyrrolidinone (NPYR), N-nitrosopiperidine (NPIP), N-nitrosomorpholine (NMOR).]
Substance | Limit value (mg/m3)
1,1,1 — trichloroethane | 0,2
4-Phenylcyclohexene | 0,02
Carbon Disulphide | 0,02
Formaldehyde | 0,005
Nitrosamines | 0,0005
Styrene | 0,01
Tetrachloroethylene | 0,15
Toluene | 0,1
Trichlorethylene | 0,05
Vinyl chloride | 0,0001
Vinyl cyclohexene | 0,002
Aromatic hydrocarbons (total) | 0,3
VOCs (total) | 0,5
Assessment and verification: the applicant shall provide a report presenting the results of the following test procedure. A test chamber analysis shall be performed in accordance with the standard ISO 16000-9. The wrapped sample shall be stored at room temperature at least for 24 hours. After this period the sample shall be unwrapped and immediately transferred into the test chamber. The sample shall be placed on a sample holder, which allows air access from all sides. The climatic factors shall be adjusted according to ISO 16000-9. For comparison of test results, the area specific ventilation rate (q = n/l) shall be 1. The ventilation rate shall be between 0,5 and 1. The air sampling shall be done 24 ± 1 h after loading of the chamber during 1 hour on DNPH cartridges for the analysis of formaldehyde and other aldehydes and on Tenax TA for the analysis of other volatile organic compounds. Sampling duration for other compounds may be longer but shall be completed before 30 hours.
The analysis of formaldehyde and other aldehydes shall comply with the standard ISO 16000-3. Unless specified differently, the analysis of other volatile organic compounds shall comply with the standard ISO 16000-6.
Testing following the standard CEN/TS 16516 shall be considered equivalent to those of the ISO 16000 series of standards.
The analysis of nitrosamines shall be done by means of gas chromatography in combination with a thermal energy analysis detector (GC-TEA), in accordance with the BGI 505-23 method (formerly: ZH 1/120.23) or equivalent.
Should dyes be used, criterion 5.5 shall be respected.
Assessment and verification: the applicant shall provide either a declaration of non-use of dyes from the manufacturer of the foam or, in case of use, a declaration of compliance with this criterion, together with supporting documentation.
Note: The following requirements need to be met only if PUR foam contributes to more than 5 % of the total weight of the mattress.
The concentrations in the PUR foam of the substances listed below shall not exceed the following values:
Group of substances | Substance (acronym, CAS number, element symbol) | Limit value | Assessment and verification conditions
Biocides | Substances restricted according to criterion 8.1 | Not added intentionally | A
Heavy Metals | As (Arsenic) | 0,2 ppm | B
Cd (Cadmium) | 0,1 ppm | B
Co (Cobalt) | 0,5 ppm | B
Cr (Chromium), total | 1,0 ppm | B
Cr VI (Chromium VI) | 0,01 ppm | B
Cu (Copper) | 2,0 ppm | B
Hg (Mercury) | 0,02 ppm | B
Ni (Nickel) | 1,0 ppm | B
Pb (Lead) | 0,2 ppm | B
Sb (Antimony) | 0,5 ppm | B
Se (Selenium) | 0,5 ppm | B
Plasticizers | Di-iso-nonylphthalate (DINP, 28553-12-0) | 0,01 % w/w (sum) | C
Di-n-octylphthalate (DNOP, 117-84-0) | |
Di (2-ethylhexyl)-phthalate (DEHP, 117-81-7)
Di-iso-decylphthalate (DIDP, 26761-40-0)
Butylbenzylphthalate (BBP, 85-68-7)
Dibutylphthalate (DBP, 84-74-2)
Phthalates | Not added intentionally | A
TDA and MDA | 2,4 Toluenediamine (2,4-TDA, 95-80-7) | 5,0 ppm | D
4,4'-Diaminodiphenylmethane | 5,0 ppm | D
(4,4'-MDA, 101-77-9) | |
Tinorganic substances | Tributyltin (TBT) | 50 ppb | E
Dibutyltin (DBT) | 100 ppb | E
Monobutyltin (MBT) | 100 ppb | E
Tetrabutyltin (TeBT) | — | —
Monooctyltin (MOT) | — | —
Dioctyltin (DOT) | — | —
Tricyclohexyltin (TcyT) | — | —
Triphenyltin (TPhT) | — | —
Sum | 500 ppb | E
Other specific susbstances that are restricted | Chlorinated or brominated dioxines or furans | Not added intentionally | A
Chlorinated hydrocarbons (1,1,2,2-Tetrachloroethane, Pentachloroethane, 1,1,2-Trichloroethane, 1,1-Dichloroethylene) | Not added intentionally | A
Chlorinated phenols (PCP, TeCP, 87-86-5) | Not added intentionally | A
Hexachlorocyclohexane (58-89-9) | Not added intentionally | A
Monomethyldibromo–Diphenylmethane (99688-47-8) | Not added intentionally | A
Monomethyldichloro-Diphenylmethane (81161-70-8) | Not added intentionally | A
Nitrites | Not added intentionally | A
Polybrominated Biphenyls (PBB, 59536-65-1) | Not added intentionally | A
Pentabromodiphenyl Ether (PeBDE, 32534-81-9) | Not added intentionally | A
Octabromodiphenyl Ether (OBDE, 32536-52-0) | Not added intentionally | A
Polychlorinated Biphenyls (PCB, 1336-36-3) | Not added intentionally | A
Polychlorinated Terphenyls (PCT, 61788-33-8) | Not added intentionally | A
Tris(2,3-dibromopropyl) phosphate (TRIS, 126-72-7) | Not added intentionally | A
Trimethylphosphate (512-56-1) | Not added intentionally | A
Tris-(aziridinyl)-phosphinoxide (TEPA, 545-55-1) | Not added intentionally | A
Tris(2-chloroethyl)-phosphate (TCEP, 115-96-8) | Not added intentionally | A
Dimethyl methylphosphonate (DMMP, 756-79-6) | Not added intentionally | A
A. For biocides, phthalates and other specific substances that are restricted the applicant shall provide a declaration supported by declarations from manufacturers of the foam confirming that the listed substances have not been added intentionally to the foam formulation.
B. For heavy metals the applicant shall provide a report presenting the results of the following test procedure. Milled sample material is eluted in accordance with DIN 38414-S4 or equivalent in a ratio of 1:10. The resultant filtrate shall be passed through a 0,45 μm membrane filter (if necessary by pressure filtration). The solution obtained shall be examined for the content of heavy metals by atomic emission spectrometry with inductively coupled plasma (ICP-AES or ICP-OES) or by atomic absorption spectrometry using a hydride or cold vapour process.
C. For the total amount of plasticizers the applicant shall provide a report presenting the results of the following test procedure. The sample shall be a composite of 6 pieces to be taken from beneath each samples face (to a maximum of 2 cm from the surface). Extraction shall be performed with dichloromethane using validated method and followed by analysis with gas chromatography–mass spectrometry (GC/MS) or high-performance liquid chromatography (HPLC/UV).
D. For TDA and MDA the applicant shall provide a report presenting the results of the following test procedure. The sample shall be a composite of 6 pieces to be taken from beneath each samples face (to a maximum of 2 cm from the surface). Extraction shall be performed with 1 % aqueous acetic acid solution. Four repeat extractions of the same foam sample shall be performed maintaining the sample weight to volume ratio of 1:5 in each case. The extracts shall be combined, made up to a known volume, filtered and analysed by high-performance liquid chromatography (HPLC-UV) or HPLC-MS. If HPLC-UV is performed and interference is suspected, reanalysis with high performance liquid chromatography–mass spectrometry (HPLC-MS) shall be performed.
E. For tinorganic substances the applicant shall provide a report presenting the results of the following test procedure. The sample shall be a composite of 6 pieces to be taken from beneath each sample face (to a maximum of 2 cm from the surface). Extraction shall be performed for 1 hour in an ultrasonic bath at room temperature. The extracting agent shall be a mixture composed as it follows: 1750 ml methanol + 300 ml acetic acid + 250 ml buffer (pH 4,5). The buffer shall be a solution of 164 g of sodium acetate in 1200 ml of water and 165 ml acetic acid, to be diluted with water to a volume of 2000 ml. After extraction the alkyl tin species shall be derivatized by adding sodium tetraethylborate solution in tetrahydrofuran (THF). The derivative shall be extracted with n-hexane and the sample shall be submitted to a second extraction procedure. Both hexane extracts shall be combined and further used to determine the organotin compounds by gas chromatography with mass selective detection in SIM modus.
The room concentrations of the substances reported below, calculated through the test chamber method, shall not exceed the following values after a period of 72 hours.
[Regulation (EC) No 1272/2008 of the European Parliament and of the Council of 16 December 2008 on classification, labelling and packaging of substances and mixtures, amending and repealing Directives 67/548/EEC and 1999/45/EC, and amending Regulation (EC) No 1907/2006 (OJ L 353, 31.12.2008, p. 1).]
Substance (CAS number) | Limit value (mg/m3)
Formaldehyde (50-00-0) | 0,005
Toluene (108-88-3) | 0,1
Styrene (100-42-5) | 0,005
Each detectable compound classified as categories C1A or C1B according to the Regulation (EC) No 1272/2008 of the European Parliament and of the Council | 0,005
Sum of all detectable compound classified as categories C1A or C1B according to Regulation (EC) No 1272/2008 | 0,04
Aromatic hydrocarbons | 0,5
VOCs (total) | 0,5
Assessment and verification: the applicant shall provide a report presenting the results of the following test procedure. The foam sample is placed on the bottom of an emission test chamber and is conditioned for 3 days at 23 °C and 50 % relative humidity, applying an air exchange rate n of 0,5 per hour and a chamber loading L of 0,4 m2/m3 (= total exposed surface of sample in relation to chamber dimensions without sealing edges and back) in accordance with ISO 16000-9 and ISO 16000-11. Sampling shall be done 72 ± 2 h after loading of the chamber during 1 hour on Tenax TA and DNPH cartridges for respectively VOC and formaldehyde analysis. The emissions of VOC are being trapped on Tenax TA sorbent tubes and subsequently analysed by means of thermo-desorption-GC-MS in accordance to ISO 16000-6. Results are semi-quantitatively expressed as toluene equivalents. All specified individual components are reported from a concentration limit ≥ 1 μg/m3. Total VOC value is the sum of all components with a concentration ≥ 1 μg/m3 and eluting within the retention time window from n-hexane (C6) to n-hexadecane (C16), both included. The sum of all detectable compounds classified as categories C1A or C1B according to Regulation (EC) No 1272/2008 is the sum of all these substances with a concentration ≥ 1 μg/m3. In case the test results exceed the standard limits, substance specific quantification needs to be performed. Formaldehyde can be determined by collection of the sampled air onto DNPH cartridge and subsequent analysis by HPLC/UV in accordance to ISO 16000-3.
Testing following the standard CEN/TS 16516 shall be considered equivalent to those of the ISO 16000 series of standards.
Chamber volume shall be 0,5 or 1 m3.
1 sample (25 cm × 20 cm × 15 cm) shall be used in a test chamber of 0,5 m3 standing vertically on one 20 cm × 15 cm side.
2 samples (25 cm × 20 cm × 15 cm) shall be used in a 1 m3 test chamber standing vertically on one 20 cm × 15 cm side; in this case both samples shall be placed in the test chamber with 15 cm distance in between.
Should dyes be used, criterion 5.5 shall be respected.
Assessment and verification: the applicant shall provide either a declaration of non-use of dyes from the manufacturer of the foam or, in case of use, a declaration of compliance with this criterion, together with supporting documentation.
Should mixed isomers of toluene diisocyanate (TDI) be used in the production of the PUR foam, the total chlorine content of these isocyanates shall not exceed 0,07 % by weight.
Assessment and verification: the applicant shall provide either a declaration of non-use from the manufacturer of the foam or the results of the test methods carried-out in accordance with ASTM D4661-93 or equivalent.
Halogenated organic compounds shall not be used as blowing agents or as auxiliary blowing agents.
Assessment and verification: the applicant shall provide a declaration of non-use from the manufacturer of the foam.
Note: The following requirements need to be met only if wire and springs contribute to more than 5 % of the total weight of the mattress.
If degreasing and/or cleaning of wire and/or springs is carried out with organic solvents, use shall be made of a closed cleaning/degreasing system.
Assessment and verification: the applicant shall provide a corresponding declaration from the manufacturer of wire and/or springs.
The surface of springs shall not be covered with a galvanic metallic layer.
Assessment and verification: the applicant shall provide a corresponding declaration from the manufacturer of wire and/or springs.
Note: The following requirement needs to be met only if coconut fibre contribute to more than 5 % of the total weight of the mattress.
Criteria for latex foam shall be considered if coconut fibre material is rubberised using latex.
Assessment and verification: the applicant shall either provide a declaration of non-use of rubberised coconut fibres, or the test reports required in criterion 1 for latex foam.
All the requirements (5.1 to 5.11) shall be respected for the mattress cover (i.e. ticking).
Filling materials (i.e. padding) shall respect requirement 5.1. Where wool is used as filling material, requirements 5.1, 5.2 and 5.8 shall be respected.
All textiles which have been awarded the EU Ecolabel, as established in Commission Decision 2014/350/EU [Commission Decision 2014/350/EU of 5 June 2014 establishing the ecological criteria for the award of the EU Ecolabel for textile products (OJ L 174, 13.6.2014, p. 45).], are considered being automatically compliant with requirements 5.1, 5.2, 5.3, 5.4, 5.5, 5.6, 5.7, 5.8, 5.10 and 5.11. Nevertheless, in order to allow mattresses to be awarded the EU Ecolabel, it shall be demonstrated that also criterion 5.9 is satisfied for the mattress cover.
All textiles: criteria 7 (flame retardants), 8 (biocides), 9 (plasticizers) and 10 (hazardous substances) shall be respected by all textiles.
Assessment and verification: the applicant shall provide a declaration of compliance with this criterion, together with the supporting documentation required in the respective criterion (7, 8, 9 and 10).
All covers: The following substances shall not be used in any preparations or formulations used for the production of all mattress covers. Limit values for the presence of Alkylophenols and APEOs on the cover shall be respected.
Filling materials made of wool: Alkylophenols and APEOs shall not be used in any preparations or formulations used for the production of filling materials made of wool and limit values for their presence in the filling material shall be respected.
Substance (CAS number/Acronym) | Limit value (mg/kg) | Assessment and verification conditions
Alkylphenols: | 25 (sum) | A
Nonylphenol, mixed isomers (25154-52-3)
4-Nonylphenol (104-40-5)
4-Nonylphenol, branched (84852-15-3)
Octylphenol (27193-28-8)
4-Octylphenol (1806-26-4)
4-tert-Octylphenol (140-66-9)
Alkylphenolethoxylates (APEOs) and their derivatives | |
Polyoxyethylated octyl phenol (9002-93-1)
Polyoxyethylated nonyl phenol (9016-45-9)
Polyoxyethylated p-nonyl phenol (26027-38-3)
bis(hydrogenated tallow alkyl) dimethyl ammonium chloride (DTDMAC) | Not used | B
distearyl dimethyl ammonium chloride (DSDMAC)
di(hardened tallow) dimethyl ammonium chloride (DHTDMAC)
ethylene diamine tetra acetate (EDTA)
diethylene triamine penta acetate (DTPA)
4-(1,1,3,3-tetramethylbutyl)phenol
1-Methyl-2-pyrrolidone
Nitrilotriacetic acid (NTA)
A. The applicant shall provide a report presenting the results of the final product testing which shall be performed through solvent extraction followed by liquid chromatography–mass spectrometry (LC-MS).
B. The applicant shall provide a declaration of non-use from the supplier supported by safety data sheets for all production stages.
All surfactants, softeners and complexing agents: At least 95 % by weight of surfactants, softeners and complexing agents shall comply with one of the following conditions:
they shall be readily biodegradable under aerobic conditions;
they shall be inherently biodegradable or eliminable in wastewater treatment plants.
Non-ionic and cationic surfactants: All non-ionic and cationic surfactants shall also be readily biodegradable under anaerobic conditions.
The latest revision of the Detergents Ingredients Database should be used as a reference point for biodegradability:
http://ec.europa.eu/environment/ecolabel/documents/did_list/didlist_part_a_en.pdf
Assessment and verification: the applicant shall provide appropriate documentation through safety data sheets and declarations from suppliers.
For all surfactants, softeners and complexing agents, this shall be supported by results of appropriate OECD or ISO tests for: